AV Systems · Power Protection · Pro AV and Residential

UPS for AV Systems

AV system power protection covers two distinct markets with different equipment, environments, and buyer requirements. Select your application below to find the right UPS solution.

Commercial · Institutional · Broadcast
Professional AV

UPS and power distribution for commercial AV integrators deploying in conference rooms, boardrooms, auditoriums, control rooms, broadcast studios, stadiums, and digital signage networks. Covers the full range from compact AV racks to stadium-scale three-phase systems.

  • Conference rooms and boardrooms
  • Control rooms and command centers
  • Broadcast studios and media production
  • Stadiums, arenas, and event venues
  • Education, government, and healthcare AV
  • Digital signage and video walls
Pro AV UPS solutions →
Residential · Smart Home · CEDIA
Home Automation and CEDIA

UPS and power protection for CEDIA integrators deploying in smart homes, home theaters, and residential AV installations. Covers structured wiring enclosures, home automation processors, whole-home network infrastructure, and estate-scale systems.

  • Home theaters and media rooms
  • Structured wiring enclosures
  • Automation processors — Control4, Crestron, Savant, Lutron
  • Residential networking and Wi-Fi
  • Whole-home and estate-level backup
  • Security and surveillance systems
CEDIA and home automation UPS →
Hum, buzz and video noise

If the system hums, the problem is usually a ground loop

Backup power and hum are separate problems, and a UPS on its own does not fix the second one. Audible hum in audio and horizontal bars rolling through video almost always trace to a ground loop: two pieces of equipment fed from different circuits sit at slightly different ground potentials, and the difference drives current through the signal cable shields that connect them. That current arrives as noise.

  • 60 Hz hum in audioConstant low-frequency hum through speakers that does not change with source or volume position.
  • Bars rolling through videoFaint horizontal bands drifting up or down the image, most visible on flat fields.
  • Noise that appears on connectionThe system is quiet until a cable is run between two racks, a projector, or a remote zone.
  • Worse with more circuitsSymptoms grow as the install spreads across more panels, floors, or outbuildings.

Why a UPS or a conditioner does not solve it

Surge suppressors, filters and double-conversion UPS all work on the waveform. A ground loop is not a waveform problem, it is a connection problem: two grounds joined through your signal cabling. Nothing that cleans the voltage will break that path. This is common mode noise, measured between ground and either neutral or line, and it is the one condition on the list of ten common power problems that online double-conversion alone does not address.

Do not lift the ground pin

A ground-lift adapter will usually silence the hum, and it does it by defeating the safety ground on that piece of equipment. That is a code violation and a shock hazard, and it leaves the underlying condition in place. It is a diagnostic, not a fix. If lifting a ground stops the noise, you have confirmed a ground loop and you now know an isolation transformer will solve it properly.

What actually fixes it

A galvanic isolation transformer. Primary and secondary share no copper, so power crosses as magnetic flux and the load gets its own derived neutral-to-ground reference. There is no longer a potential difference for current to flow through, so the loop is broken at the source rather than at the symptom. It also blocks DC on the incoming supply, which can saturate transformers inside amplifiers and produce mechanical hum from the chassis itself.

Two rules decide whether it works. Put the transformer downstream of the UPS, not upstream. And put it close to the equipment it protects, in the same rack or enclosure, because everything past the transformer secondary is unprotected cable again. Full detail on sizing and wiring is on the UPS with isolation transformer page.

Which isolation product fits

The 1.5 and 2 kW rack models are the most common choice in AV, sized to a single rack of electronics. Below that, the JX-200 handles a control processor or a signage player. Above it, the 6 and 10 kVA models also convert 208 V rack feeds down to 120 V.

Quick reference — AV UPS platforms
Model Capacity Best for Key features
J60 / J60CView → 350–600VA Control processors, routers, WAPs, small enclosures Ultra-compact · DIN rail · fanless · 15-yr LiFePO₄
J90View → 1–3kVA AV racks, PoE switches, conferencing gear 1U · outlet control · 50°C · LiFePO₄
P91LiView → 1–3kVA Boardrooms, production racks, media rooms 2U rack/tower · extended runtime · LiFePO₄
Li90View → 10–30kW Stadiums, arenas, large venue AV Three-phase · LiFePO₄ · hot-swap · frequency conversion
M90SView → 6–48kVA Whole-home estate · multi-rack AV systems Modular · scalable · N+1 redundancy
JX-200View → 200W Control processors, signage players, single components Isolation transformer · 1.25″ slim · toroidal · pairs with J60-350
XPD-IT15LV / 20LVView → 1.5–2kW AV racks — the most common isolation choice in AV Isolation PDU · 2U · 120V in/out · (16) outlets · pairs with P91
XPD-IT60AView → 6kVA Large racks needing 208V to 120V conversion plus isolation Isolation PDU · 2U · L6-30P cord · (12) 5-15/20R
SPDU Smart PDUView → Remote reboot of AV and network devices Outlet-level switching · metering · managed service support
Frequently asked questions

AV systems UPS — frequently asked questions

Why does my AV system hum, and will a UPS fix it?
A UPS on its own will not. Hum in audio and rolling bars in video are almost always a ground loop: two components fed from different circuits sit at slightly different ground potentials, and the difference drives current through the signal cable shields between them. That is a connection problem, not a waveform problem, so surge suppression, filtering and even double-conversion do not reach it. A galvanic isolation transformer does, because primary and secondary share no copper and the load gets its own derived ground reference.
Can I just use a ground-lift adapter?
No. It will usually silence the hum, and it does so by defeating the safety ground on that component, which is a code violation and a shock hazard. Treat it as a diagnostic only: if lifting the ground stops the noise, you have confirmed a ground loop and you know an isolation transformer will fix it properly. Then put the ground back.
What size isolation transformer does an AV rack need?
Size it to the load in watts, not to the UPS rating. The 1.5 kW and 2 kW rack models cover most single-rack AV systems and are the most common choice in this market. A JX-200 at 200 W suits a control processor or signage player on its own. Above 2 kW, the 6 and 10 kVA models also convert a 208 V rack feed down to 120 V. Mount the transformer in the same rack as the equipment; everything past its output is unprotected cable again.
What is the difference between Pro AV and home automation UPS solutions?
Professional AV covers commercial, institutional, broadcast, and venue installations, while home automation and CEDIA covers residential smart homes and theaters. They involve different equipment and environments — choose the path that matches your project.
Which UPS do I need for an AV system?
It depends on the load and setting: the compact J60 suits control processors, the J90 or P91Li fit AV racks and boardrooms, the Li90 three-phase serves stadiums and large venues, and the modular M90S covers whole-home or multi-rack systems. The quick-reference table lists each.
Do you support both commercial AV integrators and residential CEDIA installers?
Yes. Xtreme Power supports professional AV integrators and residential CEDIA installers, with dedicated solutions plus load and runtime planning for each type of deployment.

Not sure which solution fits your project?

Load calculations, runtime planning, and product selection for Pro AV and residential deployments.