J90i Lithium UPS | 1U Online Double-Conversion | 1–3kVA 208–240V

1000–3000 VA | 208–240V | 1U Online Double Conversion

High-density lithium rack UPS engineered for global IT, telecommunications, AV, and industrial infrastructure requiring conditioned power, compact deployment, and remote power control in 208–240V environments.



1U Rack · Online Double-Conversion · LiFePO₄ · 208–240V · 1–3kVA

J90i — 1U High-Density Online Lithium Rack UPS (208–240V)

Online double-conversion power protection in a 1U form factor with LiFePO₄ battery chemistry — up to 15-year service life, 50°C operation, individual outlet control, and external battery pack support on 2kVA and 3kVA models. The premium 1U lithium rack UPS for global IT, telecommunications, AV, and industrial infrastructure operating on 208–240V single-phase power.


J90i 1U lithium UPS installed in a 208–240V rack — LCD display showing live status, Xtreme Power branding visible, online double-conversion active

J90i 1U lithium UPS in a standard rack — LCD display showing live operating status, battery voltage, and runtime remaining

1U
Rack height
Wall mount capable

1–3kVA
Capacity range
208–240V single phase

15 yr
Battery life
ideal conditions · LiFePO₄

50°C
Full rated output
no capacity derating

TAA
Compliance
UL · cUL · RoHS

6 yr
Warranty
USA and Canada

Key features

What makes the J90i the premium 1U lithium rack UPS

Topology

Online double-conversion — zero transfer time

The J90i continuously regenerates output power through the inverter — the connected load never operates on raw utility power. No transfer delay during a power event. Output power is clean, regulated, and isolated from upstream disturbances regardless of input conditions.

Battery chemistry

LiFePO₄ — up to 15 years, no routine replacement

LiFePO₄ (lithium iron phosphate) batteries are rated for 3,000–5,000 discharge cycles and up to 15 years service life in ideal conditions. Across distributed deployments with 20 or 50 UPS units, eliminating the 3–5 year VRLA replacement cycle is a significant operational and cost advantage.

Thermal performance

50°C operation — no cooling dependency

IDF closets, telecom rooms, and industrial enclosures regularly exceed 35–40°C. VRLA batteries specified at 25°C degrade rapidly above 30°C. The J90i delivers full rated output to 50°C (122°F) with no capacity derating — a 3kVA unit is still a 3kVA unit at 122°F. Warranty terms differ for continuous operation above 40°C.

Outlet control

Individual outlet switching — remote reboot without a truck roll

Each outlet is individually switchable — a frozen switch, a hung firewall, a crashed controller can be power-cycled remotely without dispatching a technician. Across a campus with 20 IDF locations, that capability pays for itself after the first avoided service call.

Extended runtime

Up to 6 × EBP48 external packs — 2kVA and 3kVA models

The J90i-2kLiD and J90i-3kLiD support up to six EBP48 external LiFePO₄ battery packs for extended runtime — without the size and weight of VRLA battery cabinets. See the full runtime table below for exact values by load and pack count.

Form factor

1U rack — also wall-mount with included brackets

The J90i occupies 1U in a standard rack and mounts on any wall with the included bracket hardware. In IDF closets with wall-mount racks, the J90i installs clean without adapters or additional hardware — same unit, same bracket, either deployment.

Remote contacts

ROO / RPO — remote on and off

Remote On/Off and Remote Power Off contacts start and shut down the UPS from a dry contact, independent of the network card. That covers emergency power-off interlocks and building-system sequencing, and it works whether or not an SNMP card is fitted.

Coverage

$50,000 connected-equipment protection

In the USA and Canada, the J90i carries a $50,000 load protection policy covering equipment connected to the UPS. For an edge or telecom rack holding switches, controllers and processors, that is coverage on the load rather than just on the UPS.

Portfolio position

Where J90i fits in the Xtreme Power lithium lineup

Xtreme Power lithium rack UPS architecture

J60i
Ultra-compact lithium UPS · 230V · 350–600 VA standby

View J60i →

J60Ci
Short-depth lithium UPS · 230V · shallow racks and cabinets

View J60Ci →

P91g Li
Runtime-focused lithium rack/tower UPS · 2U

View P91g Li →

J90i ← this platform
208–240V · 1U · premium high-density rack UPS

You are here

Li90
10–30kVA · three-phase · facility-level lithium UPS

View Li90 →

J90i is the premium choice in 208–240V environments when 1U density, individual outlet control and lifecycle performance are the priorities. The P91g Li sits below it as the runtime-focused 2U option; the J60Ci when depth is the constraint; the J60i for ultra-compact standby duty. For 120V deployments see the J90.

Platform comparison

J90i vs competing 1U rack UPS platforms (208–240V)

Engineers standardizing 208–240V rack power most often compare the J90i against the APC Smart-UPS Ultra and the Tripp Lite (Eaton) SmartOnline series. All three are 1U online double-conversion platforms, so form factor is parity — the J90i’s differentiation is LiFePO₄ chemistry and lifecycle, 50°C thermal rating, individual per-outlet control, and warranty term.

Feature J90i APC Smart-UPS Ultra Tripp Lite (Eaton) SmartOnline
Form factor 1U 1U 1U
Topology Online double-conversion Online double-conversion Online double-conversion
Battery chemistry LiFePO₄ Lithium-ion VRLA
Individual outlet control Yes — per outlet No Switched load banks
External battery support Yes — 2kVA and 3kVA Yes Yes
Max operating temp 50°C 40°C typical 40°C typical
Wall mount Yes — brackets included Yes Optional
TAA compliant Yes Model-dependent Model-dependent
Warranty 6 years 5 years 2 years

Competitor specifications vary by model, SKU, and region; verify against current manufacturer documentation. Comparison reflects the 208–240V variants most often cross-shopped with the J90i.

For full model-by-model comparisons against the APC Smart-UPS Ultra and Tripp Lite (Eaton) SmartOnline series in 208–240V, see the J90i competitive comparison hub.
View J90i comparisons →

By model: J90i-2kLiD vs APC SRTL2K2RM1UWC · J90i-3kLiD vs APC SRTL3KRM1UWC · J90i-1.5kLiD vs Tripp Lite SUINT1500LCD1U · J90i-2kLiD vs Tripp Lite SUINT2000LCD1U

Technical specifications

J90i Series specifications

Attribute J90i Series
Topology Online double-conversion
Capacity 1000VA / 1500VA / 2000VA / 3000VA
Input voltage 208 / 220 / 230 / 240V AC · 40–70 Hz · C14 / C20 inlet
Output voltage 208 / 220 / 230 / 240V AC · see the user manual for capacity at 208V output
Receptacles (4) IEC C13 · 3kVA: (3) C13 + (1) C19 — all switchable
Frequency 50/60 Hz auto-sensing
Efficiency Online mode — up to 92% (1kVA and 1.5kVA) · 93% (2kVA) · 94.5% (3kVA) · ECO mode >96% (all models)
Battery chemistry LiFePO₄ (lithium iron phosphate)
Battery service life Up to 15 years — ideal conditions · 3,000–5,000 cycles
Operating temperature Full rated output to 50°C (122°F) with no capacity derating · warranty terms differ for continuous operation above 40°C
Form factor 1U rackmount
Dimensions (W×D×H) 1kLiD: 17.2 × 18.8 × 1.7 in (438 × 477 × 44 mm) · 1.5kLiD: 17.2 × 20.1 × 1.7 in (438 × 511 × 44 mm) · 2kLiD / 3kLiD: 17.2 × 22.8 × 1.7 in (438 × 579 × 44 mm)
Weight 1kLiD: 26.8 lb (12.2 kg) · 1.5kLiD: 27.7 lb (12.6 kg) · 2kLiD: 34.1 lb (15.5 kg) · 3kLiD: 35.2 lb (16 kg)
Internal battery LFP 25.6V / 6Ah (1kVA) · 38.4V / 6Ah (1.5kVA) · 51.2V / 5Ah (2kVA and 3kVA)
Typical recharge 4 hours (1kVA and 1.5kVA) · 1 hour (2kVA and 3kVA)
EBP48 battery pack 17.2 × 22.8 × 1.7 in (438 × 579 × 44 mm) · 30.8 lb (14 kg)
Overload capacity ≤130% for 2 min · 130–200% for 10 s · >200% for 250 ms
Altitude Up to 6,500 ft (2,000 m)
Mounting Rack or wall — brackets included standard
Outlet control Individual switchable outlets
Extended runtime External EBP48 packs — 2kVA and 3kVA models (up to 6 packs)
Monitoring Optional SNMP/Web card
Communication USB · RS-232 · optional SNMP
Remote contacts ROO (remote on/off) and RPO (remote power off) dry contacts, independent of the SNMP card
Load protection $50,000 connected-equipment protection policy (USA and Canada)
Warranty 6 years — USA and Canada · 2 years above 40°C continuous · 2 years depot outside the USA and Canada
Certifications UL-1778 · cUL · UN38.3 · RoHS · FCC Class A · TAA compliant

Runtime data

J90i runtime table — estimated minutes by load and battery configuration

Runtime values are estimated minutes at the load shown. Internal battery only for 1kVA and 1.5kVA models. The 2kVA and 3kVA models support up to six EBP48 external battery packs. Actual runtime varies by battery age, temperature, and load profile.

Model / Configuration 100VA
90W
150VA
135W
200VA
180W
300VA
270W
400VA
360W
600VA
540W
800VA
720W
1000VA
900W
1200VA
1080W
1400VA
1260W
1500VA
1350W
1600VA
1440W
1800VA
1620W
2000VA
1800W
2333VA
2100W
2666VA
2400W
3000VA
2700W
J90i-1kLiD 53 35 30 21 16 11 8.1 6.5 — — — — — — — — —
J90i-1.5kLiD — 59 44 33 24 17 13 10.5 8.8 7.5 7 — — — — — —
J90i-2kLiD — — 54 36 28 20 15 12 10 8.6 8 7.5 6.7 6 — — —
J90i-2kLiD + 1 EBP48 — — 270 180 142 100 75 60 50 43 40 38 33 30 — — —
J90i-2kLiD + 2 EBP48 — — 486 324 255 180 135 108 90 77 72 68 60 54 — — —
J90i-2kLiD + 3 EBP48 — — 703 468 368 260 195 156 130 111 104 98 87 78 — — —
J90i-2kLiD + 4 EBP48 — — 919 613 481 340 255 204 170 146 136 128 113 102 — — —
J90i-2kLiD + 5 EBP48 — — 1135 757 594 420 315 252 210 180 168 158 140 126 — — —
J90i-2kLiD + 6 EBP48 — — 1351 901 708 500 375 300 250 214 200 188 167 150 — — —
J90i-3kLiD — — — 38 28 20 15 12 10 8.6 8 7.5 6.7 6 5.1 4.5 4
J90i-3kLiD + 1 EBP48 — — — 189 142 98 73 60 50 43 40 38 33 30 26 23 20
J90i-3kLiD + 2 EBP48 — — — 341 256 176 132 108 90 77 72 68 60 54 46 41 36
J90i-3kLiD + 3 EBP48 — — — 492 369 254 191 156 130 111 104 98 87 78 67 59 52
J90i-3kLiD + 4 EBP48 — — — 644 483 333 249 204 170 146 136 128 113 102 87 77 68
J90i-3kLiD + 5 EBP48 — — — 795 596 411 308 252 210 180 168 158 140 126 108 95 84
J90i-3kLiD + 6 EBP48 — — — 946 710 489 367 300 250 214 200 188 167 150 129 113 100

All values in estimated minutes. Actual runtime varies by battery age, ambient temperature, and load profile. Download runtime PDF → · UPS sizing tool →

Certifications and documentation

Certifications

UL-1778
cUL
UN38.3
RoHS
FCC Class A
TAA Compliant

Documentation

Talk to an engineer about the J90i

Sizing, runtime planning, EBP48 pack configuration, TAA procurement support, and deployment guidance for global 208–240V and distributed infrastructure.

Common questions

J90i — frequently asked questions

What is the difference between the J90i and the J90?

Input voltage. The J90 is the 120 V platform; the J90i is the 208-240 V equivalent for racks and regions fed at higher voltage. Same 1U form factor, same LiFePO4 chemistry, same online double-conversion topology and per-outlet control. Choose on the supply at the rack, not on features.

Why does 50 degrees C matter if my rack is air conditioned?

Because most of them are not. IDF closets, telecom rooms and industrial enclosures regularly sit at 35-40 C, and VRLA batteries specified at 25 C degrade rapidly above 30 C. The J90i’s LiFePO4 chemistry and thermal design are rated to 50 C, which covers the real range of rack environments rather than the ideal one. On a distributed estate this is usually what decides battery service life.

How long do the batteries actually last?

LiFePO4 cells are rated for 3,000 to 5,000 discharge cycles and up to 15 years service life in ideal conditions. The practical comparison is against the 3 to 5 year VRLA replacement cycle. Across 20 or 50 sites, eliminating that cycle removes both the parts cost and the site visit, which is usually the larger number.

What does individual outlet switching give me?

Remote recovery without a truck roll. Each outlet is independently switchable, so a frozen switch, a hung firewall or a crashed controller can be power-cycled from wherever you are. Across a campus with 20 IDF locations, that capability typically pays for itself after the first avoided service call. Neither the APC Smart-UPS Ultra nor the Tripp Lite SmartOnline offers per-outlet control in this class.

Can I extend the runtime?

Yes, on the 2 kVA and 3 kVA models. The J90i-2kLiD and J90i-3kLiD support up to six EBP48 external LiFePO4 battery packs, without the size or weight of VRLA battery cabinets. The runtime table on this page gives exact figures by load and pack count.

Can the J90i be wall mounted?

Yes, and the brackets are included rather than optional. It occupies 1U in a standard rack or mounts on any wall with the supplied hardware. In IDF closets with wall-mount racks it installs without adapters or additional parts, so the same unit and the same bracket cover either deployment.

Is the J90i TAA compliant?

Yes, across the range. That matters on federal, state, education and healthcare contracts, where TAA eligibility on competing 1U platforms is model-dependent rather than standard.

What is the warranty?

Six years in the USA and Canada, covering electronics and battery, reducing to two years where the unit runs continuously above 40 C. Outside the USA and Canada, the warranty is two years, depot repair. Six years is longer than the APC Smart-UPS Ultra at five and the Tripp Lite SmartOnline at two.