350–600 VA | 230V | Ultra-Compact Lithium UPS
Ultra-compact lithium UPS engineered for embedded systems, control panels, and space-constrained electronic environments where traditional UPS platforms cannot be deployed.
The J60i puts a full lithium UPS behind the equipment it protects — inside a control cabinet, on a DIN rail, or flat against the wall behind a display. The IEC C14 inlet takes a locally sourced cord, so a single build ships anywhere on 230 V and only the cord changes at the border.
Slim and lightweight, the J60i delivers long-term power protection for critical electronics in space-constrained environments. LiFePO₄ chemistry provides up to 15 years of service life in standby or float applications, or 3,000-5,000 partial discharge cycles, far exceeding traditional UPS solutions, and the J60i runs continuously at temperatures up to 50 °C (122 °F).
Its compact form factor makes it ideal for automation systems, video walls, PoE switches, programmable logic controllers (PLCs), kiosks, industrial computers, and point-of-sale equipment where a conventional UPS won’t fit. Learn more in the lithium UPS guide →
Built for 230 VAC markets, CE marked and RoHS compliant.
Looking for 120 VAC? See the J60 (120V) →
Thin enough to mount on walls, under counters, or directly inside equipment and enclosures. Mounting brackets are included standard; a DIN-rail kit is optional.
Lithium Iron Phosphate batteries provide protection for up to 15 years in float service, or 3,000-5,000 partial discharge cycles, far exceeding VRLA and cutting maintenance.
Runs continuously to 50 °C (122 °F), derated above 40 °C, suited to industrial enclosures and demanding thermal environments.
Operates at up to 98% efficiency in normal mode, lowering utility cost and reducing heat output in enclosed installations.
LFP chemistry avoids the scheduled battery replacement cycle required by VRLA, reducing service visits and lifetime cost of ownership.
Mounting brackets ship as standard for wall, under-counter and enclosure installation, and an optional DIN-rail kit seats the J60i in a control cabinet beside the equipment it protects. The C14 inlet takes a locally sourced cord, so the same unit suits any 230 V region.
On the J60i-600, an optional external Web/SNMP card adds monitoring and remote on/off control of output to reboot loads, plus optional temperature and humidity monitoring.
Most UPS systems are designed for rack or floor deployment and can’t be installed inside equipment or shallow enclosures. The J60i integrates UPS functionality into an ultra-thin form factor, supporting localized continuity directly at the device or subsystem level, aligned with the distributed power architectures used in industrial systems, telecom infrastructure, and embedded electronics. Standby topology keeps operation efficient while providing reliable ride-through and controlled shutdown.
The J60i goes where a conventional UPS will not fit. At 1.25 inches thin it mounts on a wall, under a counter, on a DIN rail, or inside the equipment enclosure itself, which puts battery ride-through at the device instead of back at the rack. As a guide, 350 VA suits instrumentation and embedded electronics, while 600 VA suits communications and control systems. Runtime is sized for ride-through and controlled shutdown rather than extended operation. Size it with the UPS selector →
Programmable logic controllers and HMIs sit in cabinets that run hot and have no room for a tower UPS. LiFePO₄ operation to 50 °C and the optional DIN-rail kit let the J60i live in the panel with the equipment it protects.
A small PoE switch in a ceiling space or closet takes cameras, phones and access points down with it when it drops. The J60i holds a 30 to 50 W switch for well over an hour, long enough to ride out most utility events.
Menu boards, video walls and wayfinding screens lose their content and need a manual restart after a brief outage. The J60i mounts flat behind the panel or inside the enclosure, out of sight and out of the way.
Self-service kiosks, ticketing machines and POS terminals are often the only equipment in the room and rarely have a rack. An abrupt shutdown risks a corrupted transaction and a service call to a site with no technician on hand.
Access control and surveillance are the systems least able to afford a gap. Distributed J60i units keep each controller and recorder alive independently, without extending a single central battery across the building.
For equipment builders shipping into 230 V markets, the J60i provides power continuity as a component rather than an accessory the end user has to source. The C14 inlet means one build suits every region; only the cord changes.
| Model | Capacity | Communications | Receptacles | Full-load runtime |
|---|---|---|---|---|
| J60i-350 | 350 VA / 200 W | USB interface | (2) IEC C13 | 7 min (200 W) |
| J60i-600 | 600 VA / 360 W | DB9 (Web/SNMP capable) | (2) IEC C13 | 6 min (360 W) |
All models are 230 VAC. For 120 VAC models see the J60 →
| Capacity | |
| Power rating | 350 VA / 200 W · 600 VA / 360 W |
| Input | |
| Voltage | 230 VAC |
| Frequency | 50 / 60 Hz |
| Output | |
| Topology | Standby |
| Voltage | 230 VAC |
| Waveform | Sine wave (normal) · simulated sine wave (battery mode) |
| Frequency | 50 / 60 Hz |
| Surge suppression | 312 joules |
| Transfer time | 2-6 ms (typical) |
| Battery | |
| Type | Lithium Iron Phosphate (LiFePO₄) |
| Configuration | 350 VA: (8) 18650 cells, 2400 mAh · 600 VA: (16) 18650 cells, 4400 mAh |
| Design life | Up to 15 years in float service · 3,000-5,000 partial discharge cycles |
| Physical | |
| Dimensions 350 VA (W×D×H) | 6.9 × 8.5 × 1.25 in (175 × 216 × 32 mm)* |
| Dimensions 600 VA (W×D×H) | 7.3 × 10.8 × 1.6 in (185 × 275 × 40 mm) |
| Weight | 350 VA: 3.4 lb (1.5 kg) · 600 VA: 4.7 lb (2.1 kg) |
| Inlet | IEC C14 (line cord not supplied) |
| Receptacles | (2) IEC C13 |
| Mounting | Brackets included (wall / under-counter / enclosure); optional DIN-rail kit |
| Environment | |
| Operating temperature | 0-50 °C (32-122 °F), derating above 40 °C (104 °F) |
| Humidity | 0-90% (non-condensing) |
| Altitude | Up to 11,500 ft |
| Efficiency | Up to 98% (normal mode) |
| Communications | |
| Standard | J60i-350: USB interface (cable and software included) · J60i-600: DB9 port |
| Web/SNMP card | J60i-600 only, optional external card via DB9 port; UPS monitoring and output on/off control. Not available on J60i-350. |
| Environmental monitoring | J60i-600 only, optional device for temperature and humidity (requires Web/SNMP card). |
| Approvals | |
| Certifications | CE · IEC/EN 61000-3-2 Class A · RoHS · TAA compliant |
| Warranty | |
| Coverage | 5 years electronics + 5 years battery · 2 years where ambient is 40-50 °C · OEM and program purchases per applicable supply agreement |
| Options and packaging | |
| Available options | DIN-rail mounting kit · Web/SNMP card (J60i-600) · Environmental Monitoring Device (J60i-600) |
| Included in box | User manual · mounting brackets. Line cord not supplied — the C14 inlet takes a locally sourced cord. |
*Wall-mount brackets add 15 mm to each side. Rated cycle life assumes cell temperatures at or below 40 °C (104 °F); 15-year service life applies to standby or float applications. Actual battery life varies with discharge frequency, depth of discharge and operating temperature.
| Load (W) | 30 | 40 | 80 | 120 | 160 | 200 | 240 | 280 | 320 | 360 |
|---|---|---|---|---|---|---|---|---|---|---|
| J60i-350 (min) | 43 | 32 | 17 | 11 | 9 | 7 | — | — | — | — |
| J60i-600 (min) | 86 | 64 | 35 | 23 | 17 | 14 | 11 | 9 | 8 | 6 |
Runtimes are shown in minutes and will vary based on battery age and site conditions.
UL-1778, cTUVus and FCC apply to the 120V J60. The J60i (230V) carries CE, IEC/EN 61000-3-2 Class A and RoHS. Both are TAA compliant.
Xtreme Power Conversion supports OEM designers, industrial engineers, and infrastructure planners defining embedded power-continuity strategies for distributed electronic systems.