J60i Ultra-Compact Lithium UPS | 350-600 VA, 230V

350–600 VA | 230V | Ultra-Compact Lithium UPS

Ultra-compact lithium UPS engineered for embedded systems, control panels, and space-constrained electronic environments where traditional UPS platforms cannot be deployed.

Category:

350-600 VA · 230V · Ultra-Compact Lithium UPS

J60i Ultra-Compact Lithium UPS

An ultra-compact 230 VAC lithium UPS engineered for embedded systems, control panels, and space-constrained electronics where traditional UPS platforms can’t be deployed. At a profile as thin as 1.25 inches, the J60i integrates directly into equipment and enclosures, and LiFePO₄ batteries deliver long service life, 50 °C operation, and reduced maintenance versus VRLA.

Xtreme Power J60i ultra-compact 230V lithium UPS, slim steel enclosure with IEC C14 inlet and two IEC C13 output receptacles

J60i, IEC C14 inlet and (2) IEC C13 outlets, 1.25″ profile

1.25″
Ultra-compact profile
350-600 VA
200-360 W
Up to 98%
Efficiency (normal mode)
Up to 15 yr
LiFePO₄ float service life
50 °C
Operation (derated >40 °C)
TAA
Compliant
Overview

15-year lithium UPS built for extreme heat and tight spaces

Slim and lightweight, the J60i delivers long-term power protection for critical electronics in space-constrained environments. LiFePO₄ chemistry provides up to 15 years of service life in standby or float applications, or 3,000-5,000 partial discharge cycles, far exceeding traditional UPS solutions, and the J60i runs continuously at temperatures up to 50 °C (122 °F).

Its compact form factor makes it ideal for automation systems, video walls, PoE switches, programmable logic controllers (PLCs), kiosks, industrial computers, and point-of-sale equipment where a conventional UPS won’t fit. Learn more in the lithium UPS guide →

Looking for 120 VAC? See the J60 (120V) →

Xtreme Power J60 series ultra-compact lithium UPS beside a conventional tower UPS of similar capacity, showing the far slimmer profile
Size in perspective, the slim J60 series (left) beside a conventional 400 VA tower UPS of similar capacity.
Features

Engineered for embedded deployment

Xtreme Power J60i-350 ultra-compact lithium UPS mounted on a DIN rail inside an equipment enclosure
J60i-350 on a DIN rail, optional DIN-rail mounting kit.
Ultra-compact

1.25-inch profile

Thin enough to mount on walls, under counters, or directly inside equipment and enclosures. Mounting brackets are included standard; a DIN-rail kit is optional.

Long-life battery

LiFePO₄, up to 15 years

Lithium Iron Phosphate batteries provide protection for up to 15 years in float service, or 3,000-5,000 partial discharge cycles, far exceeding VRLA and cutting maintenance.

High temperature

Operation up to 50 °C

Runs continuously to 50 °C (122 °F), derated above 40 °C, suited to industrial enclosures and demanding thermal environments.

High efficiency

Up to 98% efficiency

Operates at up to 98% efficiency in normal mode, lowering utility cost and reducing heat output in enclosed installations.

Lifecycle cost

Maintenance-free design

LFP chemistry avoids the scheduled battery replacement cycle required by VRLA, reducing service visits and lifetime cost of ownership.

Remote control (J60i-600)

Optional Web/SNMP + output control

On the J60i-600, an optional external Web/SNMP card adds monitoring and remote on/off control of output to reboot loads, plus optional temperature and humidity monitoring.

Embedded UPS architecture

Protection at the device level

Most UPS systems are designed for rack or floor deployment and can’t be installed inside equipment or shallow enclosures. The J60i integrates UPS functionality into an ultra-thin form factor, supporting localized continuity directly at the device or subsystem level, aligned with the distributed power architectures used in industrial systems, telecom infrastructure, and embedded electronics. Standby topology keeps operation efficient while providing reliable ride-through and controlled shutdown.

Embedded / standalone · this system
J60i, ultra-compact UPS
Short-depth rack
J60Ci, short-depth UPS
Standard rack
P91 Li, rack UPS
High-density premium
J90i, lithium rack UPS
Typical applications

Where the J60i is deployed

The J60i is deployed across industrial automation systems, telecommunications equipment, OEM electronics, AV processing systems, and remote monitoring infrastructure, anywhere UPS protection must be integrated directly into equipment. As a guide, 350 VA supports instrumentation and embedded electronics, while 600 VA supports communications and control systems; runtime is intended for ride-through and controlled shutdown. Size it with the UPS selector →

Model selection

J60i model guide

Model Capacity Communications Receptacles Full-load runtime
J60i-350 350 VA / 200 W USB interface (2) IEC C13 7 min (200 W)
J60i-600 600 VA / 360 W DB9 (Web/SNMP capable) (2) IEC C13 6 min (360 W)

All models are 230 VAC. For 120 VAC models see the J60 →

Specifications

Full specifications

Capacity
Power rating 350 VA / 200 W · 600 VA / 360 W
Input
Voltage 230 VAC
Frequency 50 / 60 Hz
Output
Topology Standby
Voltage 230 VAC
Waveform Sine wave (normal) · simulated sine wave (battery mode)
Frequency 50 / 60 Hz
Surge suppression 312 joules
Transfer time 2-6 ms (typical)
Battery
Type Lithium Iron Phosphate (LiFePO₄)
Configuration 350 VA: (8) 18650 cells, 2400 mAh · 600 VA: (16) 18650 cells, 4400 mAh
Design life Up to 15 years in float service · 3,000-5,000 partial discharge cycles
Physical
Dimensions 350 VA (W×D×H) 6.9 × 8.5 × 1.25 in (175 × 216 × 32 mm)*
Dimensions 600 VA (W×D×H) 7.3 × 10.8 × 1.6 in (185 × 275 × 40 mm)
Weight 350 VA: 3.4 lb (1.5 kg) · 600 VA: 4.7 lb (2.1 kg)
Inlet IEC C14 (line cord not supplied)
Receptacles (2) IEC C13
Mounting Brackets included (wall / under-counter / enclosure); optional DIN-rail kit
Environment
Operating temperature 0-50 °C (32-122 °F), derating above 40 °C (104 °F)
Humidity 0-90% (non-condensing)
Altitude Up to 11,500 ft
Efficiency Up to 98% (normal mode)
Communications
Standard J60i-350: USB interface (cable and software included) · J60i-600: DB9 port
Web/SNMP card J60i-600 only, optional external card via DB9 port; UPS monitoring and output on/off control. Not available on J60i-350.
Environmental monitoring J60i-600 only, optional device for temperature and humidity (requires Web/SNMP card).
Approvals
Certifications CE · IEC/EN 61000-3-2 Class A · RoHS · TAA compliant
Warranty
Coverage 5 years electronics and battery (USA & Canada) · 2 years where ambient is 40-50 °C · OEM and program purchases per applicable supply agreement

*Wall-mount brackets add 15 mm to each side. Rated cycle life assumes cell temperatures at or below 40 °C (104 °F); 15-year service life applies to standby or float applications. Actual battery life varies with discharge frequency, depth of discharge and operating temperature.

Battery runtime

Runtime by load

Load (W) 30 40 80 120 160 200 240 280 320 360
J60i-350 (min) 43 32 17 11 9 7
J60i-600 (min) 86 64 35 23 17 14 11 9 8 6

Runtimes are shown in minutes and will vary based on battery age and site conditions.

Certifications

Standards & compliance

CE
IEC/EN 61000-3-2 Class A
RoHS
TAA compliant

UL-1778, cTUVus and FCC apply to the 120V J60. The J60i (230V) carries CE, IEC/EN 61000-3-2 Class A and RoHS. Both are TAA compliant.

Competitive evaluation

How the J60i compares

See how the J60 series stacks up against compact and embedded UPS platforms across profile, chemistry, lifecycle, and warranty in the comparison hub.
View J60 comparisons →

Plan with confidence

Xtreme Power Conversion supports OEM designers, industrial engineers, and infrastructure planners defining embedded power-continuity strategies for distributed electronic systems.

MODEL NUMBER J60-350 J60i-350 J60-600 J60i-600
CAPACITY Power rating 350VA (200W) 350VA (200W) 600VA (360W) 600VA (360W)
INPUT Voltage 120VAC 230VAC 120VAC 230VAC
Frequency 50/60Hz
OUTPUT Voltage 120VAC 230VAC 120VAC 230VAC
Waveform Sine wave (normal), simulated sine wave (battery mode)
Frequency 50/60Hz
Surge suppression 312 joules
Transfer time 2-6 ms (typical)
BATTERY Battery type  Lithium Iron Phosphate (LiFePo4)
Battery quantity and size (8) LiFePO4 18650 cells, 2400mAh (16) LiFePO4 18650 cells, 4400mAh
PHYSICAL Dimensions (W x D x H) 6.9 x 8.5 x 1.25 in* (175 x 216 x 32 mm) 7.3 x 10.8 x 1.6 in  (185 x 275 x 40 mm)
Weight 3.4 lbs (1.5 kg) 4.7 lbs (2.1 kg)
Line cord Detachable 5–15P to C13 C14 inlet Detachable 5–15P to C13 C14 inlet
Receptacles (3) 5–15R (2) IEC C13 (3) 5–15R (2) IEC C13
ENVIRONMENT Temperature 32–104°F (0–40°C)
Humidity 0–90%
Altitude 11,500 ft above sea level
COMMUNICATIONS INTERFACE Standard communications USB Interface including cable and software DB9 port provides communication and power for optional webcard
Web/SNMP card option N/A External Web/SNMP card providing UPS
Environmental monitoring device N/A Measures temperature and humidity (requires Web/SNMP card option)
APPROVALS UL-1778, cTUVus, FCC, RoHSCE, RoHS, TAA compliant (120V) CE, RoHS, TAA compliant (230V)
WARRANTY 5 years electronics, 5 years battery warranty (USA & Canada)**
AVAILABLE OPTIONS DIN rail mounting kit, Web/SNMP card (600VA), Environmental Monitoring Device (600VA), power cord with offset/right angle 5-15P plug (120V units only)
INCLUDED IN BOX ViewPower CD, user manual, mounting brackets, 5–15P to C13 line cord (120VAC units only)