E91 Three-Phase UPS – Expanded Capacity Facility UPS (30–40kVA, 208/120V)

30–40 kVA | 208/120V Three-Phase | Online Double-Conversion UPS

Compact centralized three-phase UPS engineered for facility infrastructure requiring higher capacity, predictable maintenance, and efficient electrical room deployment.

Category:

30–40 kVA · 208/120 VAC Three-Phase · Online Double-Conversion · Higher-Capacity Centralized Facility UPS · TAA

E91 30–40 kVA higher-capacity three-phase facility UPS

The E91 30–40 kVA is the expanded-capacity member of the compact centralized three-phase online double-conversion family (208/120V) — built for healthcare, industrial, commercial, telecommunications, and distributed IT environments that need higher centralized capacity without transitioning to modular UPS architecture. It integrates UPS electronics and VRLA batteries in a single cabinet, delivers unity output power factor for up to 25% more usable load, and installs against the wall with no rear service clearance required. Up to 94% online (98% ECO) efficiency, a 4.3-in touch LCD, frequency-converter operation, and TAA compliance. An extended-runtime 30 kVA variant (E91-30K4) is available.

30–40 kVA
Unity PF (kVA = kW)
208/120V
Three-phase (or 220/127V)
No rear
clearance — wall-mountable
94% / 98%
Online / ECO efficiency
Touch LCD
4.3-in power one-line
TAA
UL · cUL · FCC · Energy Star 2.0
Xtreme Power E91-40K higher-capacity three-phase facility UPS, front view of the tall black cabinet with a 4.3-inch color touch LCD and XTREME Power Conversion branding, on caster bases

E91-40K front view — the 30–40 kVA cabinet with a 4.3-in touch LCD and interactive power one-line, on caster bases. All E91 30–40 kVA models share this cabinet.

Overview

Higher centralized capacity, same compact architecture

The E91 30–40 kVA defines the expanded-capacity category of compact centralized three-phase UPS for localized facility infrastructure. It provides reliable double-conversion power for edge facilities, small data centers, network closets, and industrial applications — integrating UPS and battery within a single cabinet so higher capacity can be deployed without the complexity, footprint, and cost of a modular system. It is selected where infrastructure planners need more centralized capacity while keeping predictable deployment and service models.

Compact centralized architecture

Single cabinet, wall-mountable, front-serviced

The platform integrates UPS electronics and VRLA batteries within one cabinet and is engineered to save floor space: the 30 and 40 kVA models install against the wall with no rear service clearance required. Cable entry is from the top or bottom at the rear, while terminations are made at the front for accessible service. Optional external battery cabinets expand runtime without introducing modular system complexity.

Design goal How the E91 30–40 kVA delivers it
Floor-space efficiency Installs against the wall — no rear service clearance required
Accessible service Front terminations; rear top/bottom cable entry
Higher centralized capacity 30 / 40 kVA in one integrated cabinet, no modular expansion needed
Runtime flexibility Optional EBP10-5 external battery cabinets extend runtime

Key features

What the E91 30–40 kVA delivers

Capacity

Unity output power factor

Unity PF (kVA = kW) provides more real capacity for high-density loads — up to 25% more critical load than typical UPS platforms at the same kVA rating.

Footprint

No rear service clearance

The 30 and 40 kVA cabinets install against the wall with no rear clearance required, saving valuable electrical-room floor space.

Monitoring

4.3-in touch LCD

A color touch display provides an interactive power one-line, status, and alarms for at-a-glance facility monitoring.

Efficiency

Up to 94% online / 98% ECO

High-efficiency operation in double-conversion mode, with up to 98% in ECO mode, plus frequency-converter operation to lock output at 50 or 60 Hz.

Input

Dual or single inputs

Separate rectifier and bypass inputs (jumpers pre-installed) support dual- or single-feed electrical designs, with a front maintenance bypass switch for service.

Runtime

Internal VRLA + external expansion

Internal high-rate VRLA batteries with an extended-runtime 30 kVA variant (30K4), plus optional EBP10-5 external battery cabinets for longer runtimes.

Where it fits

The expanded-capacity tier of the Xtreme Power family

The E91 30–40 kVA is the higher-capacity centralized facility UPS — above the compact E91 10–20 kVA and rack-level systems, and below modular and lithium facility platforms. It is deployed in electrical rooms supporting larger localized infrastructure where higher capacity is required but modular scalability is not.

Three-phase / facility platform context

Compact facility
E91 10–20 kVA
Compact centralized VRLA UPS

View E91 10–20 →

Higher-capacity facility · this platform
E91 30–40 kVA
Expanded-capacity centralized UPS

You are here

Lithium modernization
Li90
Integrated lithium platform

View Li90 →

Modular scalable
M90U
Modular scalable UPS

View M90U →

Need smaller centralized capacity in the same architecture? See the E91 10–20 kVA.

Choosing the E91

Centralized VRLA vs modular and lithium

Modular UPS systems provide scalability and redundancy but add complexity, footprint, and cost. Lithium platforms prioritize reduced maintenance, longer battery life, and higher energy density at a higher upfront cost. The E91 30–40 kVA delivers a centralized VRLA architecture for applications where capacity requirements are defined and stable, eliminating modular expansion while simplifying installation and maintenance planning.

Consideration E91 30–40 kVA (VRLA) Modular (M90U) Lithium (Li90)
Architecture Centralized, defined capacity Scalable, redundant modules Integrated lithium
Footprint Single cabinet, wall-mountable Larger, scalable Reduced footprint
Battery model VRLA, periodic replacement VRLA / modular Lithium, long life, low maintenance
Best when Capacity is defined; simple, predictable service Growth or redundancy is required Low-maintenance modernization is the goal

Comparing battery chemistries? See lithium UPS vs lead-acid UPS.

Model selection

Three models, 30–40 kVA

Model Capacity (kVA / kW) Weight Internal battery Runtime profile
E91-30K 30 / 30 496 lb (60) × 12V 580W Standard runtime
E91-30K4 30 / 30 549 lb (80) × 12V 580W Extended runtime
E91-40K 40 / 40 551 lb (80) × 12V 580W Standard runtime

All models share a single 23.6 × 36.3 × 65.6 in cabinet with unity power factor, online double-conversion topology, a 4.3-in touch LCD, and a 16 A adjustable charger. The E91-30K4 is an extended-runtime 30 kVA variant with additional internal batteries. Optional EBP10-5 external battery cabinets ((100) × 12V 580W, 11.9 × 34 × 40.2 in) extend runtime; external maintenance bypass and output distribution are also available.

Battery runtimes

Runtime by battery configuration and load

Estimated runtime in minutes at 50% and 100% load — from internal batteries through one or two EBP10-5 external battery cabinets.

Model UPS internal batteries UPS + EBP10-5 UPS + (2) EBP10-5
Percentage load: 50% 100% 50% 100% 50% 100%
E91-30K 16 6 52 23 94 41
E91-30K4 23 9 60 26 102 44
E91-40K 16 6 42 18 73 31

Runtimes are shown in minutes and vary with battery age and site conditions. The E91-30K4 carries additional internal batteries for extended runtime at 30 kVA. Contact Xtreme Power at (800) 582-4524 or sales@xpcc.com for runtime sizing, or use the UPS sizing tool.

Applications

Where the E91 30–40 kVA is deployed

The E91 30–40 kVA is deployed across facilities requiring higher-capacity centralized UPS protection — healthcare imaging suites and multi-room clinical environments, industrial production and automation systems, commercial facility electrical infrastructure, telecommunications aggregation nodes, and distributed IT or micro data center environments. A 30 kVA system suits larger imaging or industrial electrical rooms, while 40 kVA supports broader commercial infrastructure and higher-density centralized loads, with runtime extended via external battery cabinets.

Regulated procurement

TAA-compliant facility power

The E91 is TAA compliant, supporting regulated healthcare, government, and commercial deployments requiring Trade Agreements Act compliance — alongside UL, cUL, FCC, and Energy Star 2.0.

Standardizing higher-capacity three-phase UPS across a regulated facility program?

TAA three-phase UPS →

Technical summary

E91 30–40 kVA specifications

Models E91-30K / -30K4 / -40K (30 / 30 / 40 kVA = kW) — unity PF; 30K4 is extended-runtime 30 kVA
Topology Online double-conversion, three-phase; centralized single cabinet
Input 208Y/120 VAC or 220Y/127 VAC three-phase, +20 / −15%; 46–54 Hz or 56–64 Hz; separate rectifier & bypass inputs (dual or single, jumpers pre-installed)
Output 208/120 VAC or 220/127 VAC; 50/60 Hz ±0.1%; unity power factor; frequency-converter capable
Efficiency Up to 94% online (double conversion), up to 98% ECO mode
Overload 150% for 1 minute; 125% for 10 minutes; 110% for 60 minutes
Inverter switching 19.2 kHz
Internal battery Sealed maintenance-free lead acid (VRLA), 12V 580W high-rate; (60) for 30K, (80) for 30K4 and 40K; max charging 16 A adjustable
External battery EBP10-5 ((100) × 12V 580W, 770 lb, 11.9 × 34 × 40.2 in)
Installation Against-the-wall (no rear service clearance); front terminations; top/bottom cable entry from rear
Display 4.3-in color touch LCD — interactive power one-line, status, and alarms
Dimensions / weight 23.6 × 36.3 × 65.6 in (all models); 496 / 549 / 551 lb (30K / 30K4 / 40K)
Communications RS-232, EPO, USB; intelligent slot for optional Web/SNMP and Relay/dry contact cards
Environment 32–104°F (0–40°C); altitude 5,200 ft (derates above 40°C and 5,200 ft)
Approvals UL, cUL, FCC, Energy Star 2.0, TAA compliant
Warranty 2 years electronics, 2 years battery (USA and Canada)
Options External maintenance bypass, output distribution, external battery cabinets

Plan your E91 30–40 kVA deployment

Talk to an Xtreme Power specialist about capacity selection, extended-runtime (30K4) and external battery sizing, dual-feed electrical design, against-the-wall installation, and higher-capacity centralized three-phase deployment for healthcare, industrial, telecom, and distributed IT environments.

MODEL NUMBER E91-30K E91-30K4 E91-40K
CAPACITY Power rating 30kVA/30kW 30kVA/30kW 40kVA/40kW
INPUT Voltage / Range 208Y/120VAC or 220Y/127 +20/-15% VAC three-phase
Frequency 46–54Hz or 56-64Hz
OUTPUT Voltage / Frequency 208/120VAC or 220/127VAC / 50/60±0.1%
Overload capacity 150% for 1 min, 125% for 10 min, 110% for 60 min
Inverter switching frequency 19.2 kHz
Efficiency up to 94% online mode or 98% ECO mode
INTERNAL BATTERY Battery type Sealed maintenance-lead acid
Battery quantity (60) 12V/580W (80) 12V/580W
Max charging adjustable 16A
PHYSICAL Dimensions (W x D x H) 23.6” x 36.3” x 65.6”
Weight 496 lbs 549 lbs 551 lbs
OPTIONAL BATTERY PACK Model EBP10-5
Battery quantity and size (100) 12V 580W
Weight & Dimensions (W x D x H) 770 lbs / 11.9″ x 34″ x 40.2″
ENVIRONMENT Operating temperature 32–104°F (0–40°C)*
Altitude 5,200 ft above sea level*
APPROVALS UL, cUL, FCC
WARRANTY 2 years warranty (USA and Canada)
COMMUNICATIONS INTERFACE RS-232, EPO, USB, intelligent slot for optional cards (Web/SNMP, Relay/dry contact)
INCLUDED IN BOX User manual, RS-232 communication cable, USB cable
AVAILABLE OPTIONS External maintenance bypass, output distribution, external battery cabinets