Li90 · 20 kW · Three-Phase Lithium · 208/120V

Li90 20 kW: compact three-phase lithium UPS with up to 22 minutes internal runtime

The Li90 20 kW delivers full 20kW three-phase power with integrated LiFePO₄ batteries and up to 22 minutes of internal runtime in a 12.6″ slim cabinet, no external battery cabinets required. Factory start-up and 2 years of on-site service are included in the USA. Designed for facility electrical rooms, telecom infrastructure, and industrial control environments requiring higher-capacity lithium UPS protection in space-constrained locations.

Li90 20 kW three-phase lithium UPS with battery door open, showing the integrated hot-swappable LiFePO4 modules, no external battery cabinet
The Li90 20 kW delivers full 20kW with all runtime integrated inside the 12.6″ cabinet, no external battery frames
20kW
Output capacity
208/120V three-phase
22 min
Max internal runtime
at full 20kW · 3 modules
12.6″
Cabinet width
no external cabinets
50°C
Max operating temp
no derating to 40°C
15 yr
Battery service life
ideal conditions · hot-swap
Internal Runtime Flexibility

15 or 22 minutes internal runtime, no external cabinets

The Li90 20 kW supports 2 or 3 internal LiFePO₄ battery modules. A minimum of 2 modules is required at 20kW capacity; adding a third extends runtime from 15 to 22 minutes at full load. This internal-runtime capability is uncommon in compact 20kVA UPS systems, competing platforms typically require external battery cabinets to achieve equivalent backup duration.

15
min at 20kW
2 battery modules
30 min at 10kW
22
min at 20kW
3 battery modules
45 min at 10kW

Each LiFePO₄ module is 50 Ah / 57.6 V / 2,880 Wh · 81 lbs · hot-swappable without powering down the load.

Key Features

Li90 20 kW platform features

Li90 4.3 inch color touchscreen showing the single-line mimic diagram with bypass, rectifier, inverter, and output stages
The 4.3″ color touchscreen, single-line mimic, output phase voltages, frequency, event logging, and ON/OFF/EPO controls

Online double-conversion, zero transfer time

The connected load never operates on raw utility power. No transfer delay during power events. Output is clean, regulated, and protected from upstream disturbances at all times.

50°C operation, telecom and industrial environments

Reliable operation to 50°C (122°F) without derating until 40°C. Suitable for facility electrical rooms, telecom infrastructure, and industrial spaces where VRLA UPS systems require supplemental cooling.

Hot-swappable LiFePO₄ modules, no downtime

Modules are replaced without tools and without powering down the load. Up to 15-year service life in ideal conditions, eliminating the recurring replacement cycles of VRLA battery systems.

4.3″ touchscreen · SNMP · dry contacts

Color touchscreen with single-line mimic, event logging, and access control. Two slots for SNMP/Web management cards. Programmable dry contacts (1 in / 5 out) for facility integration and BMS connectivity.

Maintenance bypass, no external switchgear

Integrated maintenance bypass allows safe servicing without powering down the load. No external bypass cabinet or switchgear required, simplifying installation in constrained electrical rooms.

110% overload for 60 min · 150% for 1 min

High overload capacity handles inrush and startup surges from motors, compressors, and inductive facility loads without nuisance tripping or transfer to bypass.

vs VRLA Alternatives

Li90 20 kW vs. typical 20kVA VRLA UPS systems

FeatureLi90 20 kWTypical 20kVA VRLA UPS
Internal runtimeUp to 22 min5–10 min
External cabinets requiredNoYes for >10–15 min
Battery technologyLiFePO₄ lithiumVRLA lead acid
Battery service lifeUp to 15 years3–5 years
Operating temperature50°C40°C UPS; batteries rated at 25°C
Cabinet footprint12.6″ · compact single cabinetLarge with external battery frames
Installation complexityLowHigher
Battery serviceHot-swap · no downtimeDowntime planning required

See head-to-head comparisons against Eaton, Vertiv, and APC on the Li90 comparison hub →

Technical Specifications

Li90 20 kW specifications

Rated power20 kVA / 20 kW
TopologyOnline double-conversion
Input voltage208/120V · 3-phase · 4W + G
Output voltage208/120V · 3-phase
Battery chemistryLiFePO₄ (lithium iron phosphate)
Battery module capacity50 Ah / 57.6 V / 2,880 Wh · 81 lbs each
Battery modules2–3 (minimum 2 required, hot-swappable)
Internal runtime15 min (2 modules) · 22 min (3 modules) at 20kW
Battery service lifeUp to 15 years ideal conditions · 3,000–5,000 cycles
Operating temperatureUp to 50°C (122°F) · no derating to 40°C
Cabinet width12.6″
System weight227 lbs cabinet + 81 lbs per module · approx 390 lbs with 2 modules
Battery locationInternal, no external cabinets required
Overload110% for 60 min · 150% for 1 min
Display4.3″ color touchscreen · single-line mimic · event log
Communication2 slots, optional SNMP/Web · dry contacts (1 in / 5 out)
ApprovalsUL 1778 · UN 38.3 · UL 1973 · not currently cUL
Warranty and service2 years UPS, 5 years battery (USA; battery 2 years for 40–50°C ambient). Factory start-up and 2 years on-site service within 100 miles of an XPC service center; travel charges apply beyond. 2 years depot repair outside the USA.
Applications

Li90 20 kW deployment environments

Li90 Family

Li90 three-phase lithium UPS, all capacities

10kW
Up to 45 min runtime · 1–3 modules · edge and telecom
View 10kW →
20kW
Up to 22 min runtime · 2–3 modules · facility and mid-tier
← current page
30kW
15 min runtime · 3 modules · slimmest 30 kW available
View 30kW →
Engineering Documents

Documentation

Li90 20 kW: frequently asked questions

What is the runtime of the Li90 20 kW?
About 15 minutes at full 20 kW load with two battery modules and 22 minutes with three, all internal. At 10 kW load the same configurations run about 30 and 45 minutes.
Why does the 20 kW model need at least two battery modules?
Each module supplies part of the DC bus power through its own DC-DC converter. At 20 kW the load needs at least two modules; a third adds runtime.
Does the Li90 20 kW need external battery cabinets?
No. The two or three LiFePO₄ modules install inside the cabinet, so the full 20 kW system fits in a 12.6-inch-wide footprint.
How does the Li90 20 kW compare to a 20kVA VRLA UPS?
LiFePO₄ batteries last up to 15 years, 3 to 4 times longer than VRLA, tolerate heat to 50 °C, and sit inside one 12.6-inch cabinet instead of a UPS plus external battery cabinets.
What service and warranty are included?
In the USA, factory start-up and 2 years of on-site service within 100 miles of an XPC service center, with travel charges beyond. Warranty is 2 years on the UPS and 5 years on the battery, with the battery term at 2 years for ambient of 40 to 50 °C.
What electrical service does it need?
208/220 V three-phase, 4W + G, with separate rectifier and bypass inputs for dual-feed designs. Output is selectable at 190, 200, 208 or 220 V.