← Li90 platform overview Li90 · 10kVA / 10kW · Three-Phase Lithium · 208/120V

Li90 10kVA — Compact Three-Phase Lithium UPS with Up to 45 Minutes Internal Runtime

The Li90 10kVA delivers full 10kW three-phase power with integrated LiFePO₄ batteries and up to 45 minutes of internal runtime in a 12.6″ slim cabinet — no external battery cabinets required. Designed for telecom rooms, small electrical spaces, and edge deployments where space, weight, and temperature constraints limit traditional UPS options.

10kW
Output capacity
208/120V three-phase
45 min
Max internal runtime
at full 10kW · 3 modules
12.6″
Cabinet width
no external cabinets
50°C
Max operating temp
LiFePO₄ · no derating to 40°C
15 yr
Battery service life
ideal conditions · hot-swap
Li90 three-phase lithium UPS installed between server racks in data center — slim 12.6 inch cabinet with touchscreen display visible
Li90 installed between server racks — slim 12.6″ cabinet fits where conventional three-phase UPS systems cannot
Internal runtime flexibility

Scalable runtime — 15, 30, or 45 minutes without external cabinets

The Li90 10kVA supports 1, 2, or 3 internal LiFePO₄ battery modules — each adding approximately 15 minutes of runtime at full 10kW load. Select the module count that matches your runtime requirement. All modules are hot-swappable and fit inside the UPS enclosure.

15
minutes at 10kW
1 battery module
29 min at 5kW
30
minutes at 10kW
2 battery modules
58 min at 5kW
45
minutes at 10kW
3 battery modules
87 min at 5kW
Li90 LiFePO4 battery module — 50AH 57.6V 2880Wh hot-swappable module for Li90 three-phase lithium UPS
Li90 LiFePO₄ battery module — 50AH / 57.6V / 2,880Wh · 80 lbs · hot-swappable without powering down the load

This internal runtime capability is uncommon in compact three-phase UPS systems — competing 10kVA platforms typically require external battery cabinets to achieve more than short-duration backup. The Li90 integrates all runtime within the UPS cabinet itself.

Key features

Built for distributed and edge infrastructure

Li90 4.3 inch touchscreen LCD showing single-line mimic diagram with bypass REC INV and output stages — ON OFF EPO buttons and Xtreme Power branding
Li90 4.3″ touchscreen — single-line mimic diagram, output phase voltages (A: 125.6V B: 121.1V C: 121.6V), frequency (59.8Hz), ON/OFF/EPO controls
Online double-conversion — zero transfer time

Continuous online double-conversion topology — the connected load never operates on raw utility power. No transfer delay during power events. Output is clean, regulated, and isolated from upstream disturbances.

50°C operation — no cooling dependency

Rated for reliable operation to 50°C (122°F). Suitable for telecom shelters, unconditioned electrical rooms, and industrial spaces where VRLA systems require supplemental cooling or derating.

Hot-swappable battery modules — no downtime

Battery modules are replaced without tools and without powering down the load. The door opens, modules slide in and out. No maintenance window required. Up to 15-year LiFePO₄ service life.

4.3″ touchscreen with SNMP monitoring

Full-color touchscreen showing single-line mimic, phase voltages, frequency, and event log. Two communication slots for optional SNMP/Web management cards. Programmable dry contacts for facility integration.

Full breaker design — maintenance bypass included

Input, output, bypass, and maintenance bypass breakers integrated in the cabinet. Service the UPS safely without powering down the load. No external switchgear or bypass cabinet required.

Conformal coated PCBs · smart de-dust fans

Circuit boards are conformal coated for industrial and high-humidity environments. Self-cleaning fan system reduces maintenance and extends service life in dusty locations.

vs VRLA alternatives

Li90 10kVA vs typical 10kVA VRLA UPS systems

FeatureLi90 10kVATypical 10kVA VRLA UPS
Internal runtimeUp to 45 min5–10 min
External cabinets requiredNoYes for >15 min
Battery technologyLiFePO₄ lithiumVRLA lead acid
Battery service lifeUp to 15 years3–5 years
Operating temperature50°C25–30°C
Cabinet footprint12.6″ wide · compactLarge with cabinets
Battery serviceHot-swap · no downtimeDowntime planning required
MaintenanceMinimalHigher — recurring replacement
Technical specifications

Li90 10kVA specifications

AttributeSpecification
Rated power10 kVA / 10 kW
TopologyOnline double-conversion
Input voltage208/120V · 3-phase
Output voltage208/120V · 3-phase
Battery chemistryLiFePO₄ (lithium iron phosphate)
Battery module capacity50AH / 57.6V / 2,880Wh · 80 lbs each
Battery modules1–3 (hot-swappable)
Internal runtime15 min (1 module) · 30 min (2 modules) · 45 min (3 modules) at 10kW
Battery service lifeUp to 15 years ideal conditions · 3,000–5,000 cycles
Operating temperatureUp to 50°C (122°F) · no derating to 40°C
Cabinet width12.6″
Battery locationInternal — no external cabinets required
Overload110% for 60 min · 150% for 1 min
Display4.3″ color touchscreen · single-line mimic · event log
Communication2 slots — optional SNMP/Web · dry contacts (1 in / 5 out)
ApprovalsUL1778 · UL38.3 · UL1973 · not currently cUL
Warranty2-year on-site UPS · 5-year battery (USA · up to 40°C)
Applications

Li90 10kVA deployment environments

Telecom rooms and communication infrastructure
Industrial lithium UPS →
Small electrical rooms and edge data sites
Edge data center UPS →
Industrial control and automation rooms
Industrial automation UPS →
Hospitality and building infrastructure
Retail and edge UPS →
High-temperature and harsh environments
Harsh environment UPS →
Distributed building systems
Li90 platform overview →
Li90 family

Li90 three-phase lithium UPS — all capacities

10kW
Up to 45 min runtime · 1–3 modules · edge and telecom
← current page
20kW
Up to 22 min runtime · 2–3 modules · facility and mid-tier
View 20kW →
30kW
15 min runtime · 3 modules · slimmest 30kVA available
View 30kW →

Request Li90 10kVA engineering pricing or runtime configuration

Module configuration, runtime sizing, site evaluation, and installation planning for the Li90 10kVA.