208V · 30A Circuit · Product Index

5kVA 208V UPS Systems for 30A L6-30R Circuits

A 208V 30A circuit with an L6-30R receptacle supports up to 5kVA — the 80% continuous load rule limits a 30A breaker to 24A continuous, which is 4,992W at 208V. Four platforms cover this capacity across line-interactive, online, isolation, and lithium topologies.

Circuit 208V · 30A
Receptacle NEMA L6-30R
UPS plug NEMA L6-30P
Max continuous (80%) 24A · 4,992W
Max UPS size 5kVA
Larger systems require hardwired input or higher-rated electrical infrastructure.
All platforms

Four platforms — find the right one for your application

This capacity tier introduces a topology not available at 120V — the isolation UPS. The TX91 is the right choice when power quality and electrical isolation matter as much as battery backup. For straightforward backup power, the P80g and P91 cover the range from cost-effective to fully conditioned. A lithium 1U option arrives December 2026.

Line-interactive · Lead acid
P80g-5000
P80g Series · Rack/Tower · 5000VA · 208V
Cost-effective 5kVA 208V UPS for branch offices and light IT where basic battery backup is the requirement.

Line-interactive topology with AVR voltage regulation. Convertible rack/tower form factor. External battery packs extend runtime. The most economical 5kVA 208V option for deployments where online double-conversion is not required and upfront cost is the primary constraint — branch offices, light commercial IT, and non-critical infrastructure.

TopologyLine-interactive
BatteryVRLA lead acid
Voltage208V input / 208V or 120V output
Extended runtimeYes — external pack
View P80g-5000 →
Online · Lead acid
P91-5k
P91 Series · Rack/Tower · 5kVA · 208V
Online double-conversion for network, AV, and critical infrastructure requiring continuous power conditioning.

Online double-conversion — zero transfer time, continuous power conditioning regardless of utility conditions. Convertible rack/tower form factor. External battery packs extend runtime. The standard 5kVA 208V online UPS for network infrastructure, AV systems, and distributed edge deployments on dedicated 30A circuits.

TopologyOnline double-conversion
BatteryVRLA lead acid
Voltage208V input / 208V or 120V output
Extended runtimeYes — external pack
View P91-5k →
Online · Isolation · Lead acid
TX91 Series
TX91 · Rack/Tower · 3.8–10kVA · 240V input / 120V or 208V output
Isolation UPS — when electrical noise filtering, galvanic separation, or voltage step-down matter as much as battery backup.

Online double-conversion with an integrated isolation transformer — providing galvanic separation between the utility feed and the protected load. The TX91 is the right choice when facility electrical noise, grounding instability, or shared circuits with motor loads are affecting sensitive equipment. Also provides voltage step-down from 240V to 120V or 208V output. Available in 3.8–10kVA — the 5kVA point sits within this range.

TopologyOnline + isolation transformer
BatteryVRLA lead acid
Input240V
Output120V or 208V
Capacity range3.8–10 kVA
View TX91 →
Online · Lithium · Coming December 2026
J90 5kVA
J90 Series · 1U · 5kVA · 208V · LiFePO₄
Ultra-compact 1U lithium UPS for high-density racks — bringing LiFePO₄ service life and high-temperature capability to 5kVA 208V deployments.

A 1U 5kVA online lithium UPS at 208V — combining the J90 platform’s LiFePO₄ battery chemistry, switchable outlets, remote reboot capability, and 50°C operation at 5kVA capacity. Designed for shallow racks and distributed edge deployments where power density and long service life matter. Shipping December 2026.

TopologyOnline double-conversion
BatteryLiFePO₄ lithium
Form factor1U + 1U rack
StatusShipping December 2026
Check availability →
Platform comparison

All 5kVA 208V platforms compared

Platform Topology Battery Form factor Ext. runtime Best for
P80g-5000 Line-interactive Lead acid Rack/tower Yes Cost-sensitive IT, branch offices, light commercial
P91-5k Online Lead acid Rack/tower Yes Network, AV, critical distributed infrastructure
TX91 Series Online + isolation Lead acid Rack/tower Yes Lab, industrial, noisy electrical environments
J90 5kVA Online Lithium 1U + 1U rack Yes High-density racks, edge, long service life Dec 2026
Runtime guidance

Typical runtime at 5kVA · 208V

Runtime depends on actual load. A 5kVA UPS running a 1500W network stack runs significantly longer than the same UPS at 4000W. External battery packs are available for the P80g, P91, and TX91 for applications requiring extended runtime beyond the internal battery.

Approximate runtime by load — internal battery only
1000–1500W load 20–40 minutes typical
2500W load 10–20 minutes typical
4000W load 5–12 minutes typical
Extended runtime models P80g, P91, TX91, J90-5K — external battery packs available
Runtime varies by model, battery age, temperature, and load profile. Use the sizing tool for model-specific calculations.
Calculate exact runtime for your load and battery configuration using the UPS sizing tool.
UPS sizing tool →

Need help selecting a 5kVA 208V UPS?

UPS sizing, runtime planning, topology selection, isolation UPS guidance, and circuit compatibility — from Xtreme Power engineering specialists.