5–6 kVA · 208–240 V · Lithium UPS Comparison

J90 5kW vs Eaton 9PX6KG2-L 6 kVA Lithium

The Eaton 9PX6KG2-L is labeled 6 kVA, but on an L6-30P cord at 208 V Eaton rates it 4800 W. The Xtreme Power J90 5kW delivers 5000 W on the same circuit, in 2U instead of 3U, 5 in shallower and 27 lbs lighter, with a 6-year warranty and TAA compliance. The Eaton runs longer from its internal battery and has outlets and a network card built in.

Xtreme Power
J90 5kW Lithium (J90-5k + 1 BPLi1U192A)
vs
Eaton
9PX G2 6000VA Lithium (9PX6KG2-L)
Where the J90 5kW leads

What the J90 5kW brings

  • 5000 W at 208 V on L6-30, vs 4800 W
  • 2U with one battery pack, vs 3U
  • 21.9 in deep, vs 26.93 in
  • 59.6 lbs with one pack, vs 86.64 lbs
  • More runtime in the same 3U: 11 min at 5 kW vs 8 min
  • Rated to 50 °C (122 °F), vs 40 °C
  • Battery life up to 15 years in ideal conditions, vs up to 10
  • 6-year warranty, vs 5 years
  • TAA compliant, built in Taiwan
Side-by-side

Side-by-side specifications

SpecificationXtreme Power J90 5kWEaton 9PX6KG2-LAdvantage / consideration
TopologyOnline double conversion, 0 ms transferOnline double conversion, 0 ms transferEqual protection
Rating5000 VA / 5000 W6000 VA / 5400 WLabel differs; see 208 V
Output at 208 V on L6-30P5000 VA / 5000 W5400 VA / 4800 WJ90 5kW – more watts at 208 V
Input connectionL6-30P, 10 ft cordL6-30P, 10 ft cordEqual
Output receptacles(2) L6-30R; optional XPD50 PDU or XBDM-J90A bypass PDU (rear-rail, front or vertical mount) adds (2) L6-20R and (2) L6-30R(2) L6-20R, (2) L6-30REaton – outlets built in
Maintenance bypassInternal automatic bypass; optional rear-panel XBDM-J90A maintenance bypass PDUInternal bypass; optional external maintenance bypass moduleBoth offer a bypass option
Rack space with base battery2U: 1U UPS + 1U lithium battery pack3U, internal batteryJ90 5kW – one less U
Depth21.9 in26.93 inJ90 5kW – 5.0 in shallower
Weight with base battery59.6 lbs (25.4 UPS + 34.2 pack)86.64 lbsJ90 5kW – 27 lbs lighter
Battery chemistryLithium iron phosphate (LFP) with BMSLithium iron phosphate (LFP) with BMSEqual
Runtime at full load, base battery5.2 min at 5000 W (one 1U lithium battery pack)8.0 min at 5400 W (internal)Eaton – longer base runtime
Runtime at full load in 3U11 min at 5000 W (UPS + 2 lithium battery packs)8.0 min at 5400 WJ90 5kW – more runtime per U
Battery service lifeUp to 15 years in ideal conditionsUp to 10 yearsJ90 5kW – longer battery life
Operating temperatureTo 50 °C (122 °F), full 5000 W with no derating0 to 40 °C (104 °F)J90 5kW – rated to 50 °C
Audible noise< 55 dBA< 43 dB at 1 mEaton – quieter
Network managementOptional SNMP-2PV3 card; USB and EPO standardNETWORK-M3 Gigabit card includedEaton – network card included
TAA complianceUPS, battery packs, XPD50 and XBDM-J90A TAA compliant, built in TaiwanCountry of origin Philippines per Eaton distributors; not a TAA-designated countryJ90 5kW – federal and GSA buyers
Standard warranty (USA)6 years electronics and battery5-year limitedJ90 5kW – one more year

J90 5kW Lithium (J90-5k with one BPLi1U192A battery pack) against the Eaton 9PX6KG2-L with its internal battery. Eaton full-load runtime is published at 5400 W. J90 5kW runtimes are calculated ahead of its March 2027 release; UL listing pending. TAA applies to the UPS, battery packs, XPD50 and XBDM-J90A; the optional XPD-IT60A isolation PDU is not TAA compliant. Runtimes vary with battery age, temperature and load. Specifications based on manufacturer documentation as of November 2026; confirm against current vendor data. Eaton is a trademark of Eaton Corporation.

Where each fits

Choosing between them

On a 30 A L6-30 circuit at 208 V, the J90 5kW delivers more power from less rack space, with longer battery life, a longer warranty and TAA compliance. The Eaton runs longer from its base battery, is quieter, and includes outlets and a network card.

Choose the J90 5kW if you need

  • The most power from a plug-in L6-30 circuit at 208 V
  • 2U instead of 3U, and a shallower, lighter unit
  • Operation in warm closets or edge sites, to 50 °C
  • Long battery life and a 6-year warranty
  • TAA compliance for federal, state or GSA purchases
  • The option of lower-cost lead-acid packs

The Eaton 9PX6KG2-L may fit if you need

  • Longer runtime from the base unit
  • Outlets and a network card in the box
  • A quieter unit for occupied spaces
  • A UPS before March 2027, or an existing Eaton fleet
Questions

Frequently asked questions

Is a 6 kVA Eaton 9PX more powerful than the 5 kW J90?
Not on an L6-30 circuit at 208 V. Eaton rates the 9PX6KG2-L at 5400 VA / 4800 W at 208 V on its L6-30P cord; the J90 5kW delivers 5000 W. Its 6000 VA label applies at 230 to 240 V. If your rack has an L6-30R receptacle, the J90 5kW gives you more usable power.
How does runtime compare?
Out of the box, the Eaton runs longer: 8.0 minutes at 5400 W from its internal battery, against 5.2 minutes at 5000 W from one J90 lithium pack. In the same 3U of rack space, the J90 5kW with two lithium packs runs about 11 minutes at 5 kW.
Can I replace the UPS without shutting down my equipment?
Both offer a way. The J90 5kW uses the optional XBDM-J90A maintenance bypass PDU, which mounts on the rear rails, sits between the wall receptacle and the UPS, and carries the outlets. Turn its switch to Bypass and the load runs on utility power while the UPS is serviced or swapped. Eaton offers an external maintenance bypass module for the 9PX.
Is the J90 5kW TAA compliant?
Yes. The J90 5kW UPS, its battery packs, and the XPD50 and XBDM-J90A PDUs are built in Taiwan and TAA compliant for federal, state and GSA purchases. Eaton distributors list the 9PX6KG2-L as made in the Philippines, which is not a TAA-designated country under FAR 25.003.
When can I buy the J90 5kW?
The J90 5kW ships in March 2027. Contact sales@xpcc.com to plan projects or quote ahead of release.

Quoting against an Eaton 9PX?

Send us the load, voltage and runtime target. Our applications team will size the J90 5kW and its battery packs and send a quote ahead of release.