P80 Line-Interactive UPS – 800–3000 VA 120V Rack/Tower UPS

800–3000 VA | 120V | Line-Interactive UPS

Rack-mounted UPS platform engineered for distributed infrastructure requiring efficient power protection, voltage regulation, and standardized deployment across multiple sites..

The P80 Series is a line-interactive rack UPS designed for network, AV, and distributed IT environments where continuous power conditioning is not required but reliable battery backup and voltage regulation are essential.

It provides rack-level continuity across multiple infrastructure locations while maintaining high efficiency and simplified deployment compared to online double-conversion systems.

P80 is commonly deployed in IDF/MDF environments and network closets as part of a standardized rack power architecture.

Key Specifications

  • 800 / 1500 / 2200 / 3000 VA
  • 120V single phase
  • Line-interactive topology
  • Pure sine wave output
  • Automatic Voltage Regulation (AVR)
  • Rack / tower convertible
  • Internal VRLA batteries with optional external expansion

Datasheet:
https://xpcc.com/wp-content/uploads/p80_flyer.pdf

Efficient Rack-Level Power Protection

P80 is designed for environments where utility power is relatively stable and full-time double conversion is not required.

Line-interactive topology regulates voltage using AVR while maintaining high operating efficiency. During outages, the system transfers to battery to support ride-through and controlled shutdown of connected equipment.

This provides a practical balance between protection, efficiency, and cost for distributed infrastructure.

Where P80 Fits

P80 operates as the standard line-interactive UPS platform within distributed rack environments.

It is typically deployed:

  • across multiple racks within IDF/MDF environments
  • in telecommunications and structured cabling systems
  • in AV, security, and commercial infrastructure

Within the Xtreme Power architecture:

  • A60 / S71 → entry-level UPS
  • P80 → line-interactive rack UPS (this platform)
  • P80g → global 208–240V equivalent
  • P91 → online UPS for higher protection requirements
  • J90 → high-density lithium UPS

P80 vs Online Double-Conversion UPS

Compared to online UPS platforms, P80 is designed for applications where full-time power conditioning is not necessary.

It offers higher operating efficiency, lower system complexity, and reduced cost while still providing battery backup and voltage regulation.

Online UPS systems such as P91 are typically selected when zero transfer time, generator coordination, or highly sensitive loads require continuous conditioning.

Replace APC / Eaton Line-Interactive UPS

P80 is commonly deployed as a replacement for legacy rack UPS systems including:

  • APC Smart-UPS SMT series
  • Eaton 5P and similar line-interactive platforms
  • Vertiv Liebert PSI systems

It provides a standardized platform for distributed infrastructure with simplified deployment and consistent lifecycle management across multiple sites.

Detailed comparisons:
https://xpcc.com/p80-ups-comparisons/

Rack Integration and Power Distribution

P80 supports multiple output receptacles, allowing a single UPS to protect multiple devices within a rack.

It is commonly deployed with rack-mounted power distribution, including intelligent PDUs (see https://xpcc.com/spdu-rack-pdu-120v/), to enable outlet-level control, monitoring, and simplified power management.

This combination provides a standardized approach to rack-level power across distributed environments.

Runtime Architecture and Deployment Flexibility

Internal batteries provide standard ride-through capability, while optional external battery expansion supports extended runtime when required.

This allows runtime to be adjusted based on application needs without changing the UPS platform, supporting consistent deployment across multiple sites.

UPS sizing tool:
https://xpcc.com/selector

Typical Applications

P80 is deployed across distributed infrastructure environments including:

It is particularly well suited for multi-site deployments where a consistent, efficient UPS platform is required.

Capacity Guidance

Capacity selection is based on load and deployment scale:

  • 800–1500 VA → small racks, security systems, edge devices
  • 2200–3000 VA → network infrastructure and distributed IT

P80 is typically standardized across multiple sites to simplify lifecycle management and spare strategy.

Technical Summary

  • Topology: Line-interactive
  • Capacity: 800–3000 VA
  • Voltage: 120V
  • Battery: VRLA (internal + optional expansion)
  • Form Factor: Rack / tower
  • Runtime: Expandable
  • Function: Voltage regulation and battery backup

Plan With Confidence

Xtreme Power Conversion supports UPS selection, capacity planning, and distributed rack architecture design across enterprise and commercial environments.

(800) 582-4524
sales@xpcc.com

MODEL NUMBER P80-800 P80-1100 P80-1500 P80-2000 P80-2200 P80-3000(V2)
CAPACITY Power rating 800VA (720W) 1100VA (990W) 1500VA (1350W) 2000VA (1800W) 2200VA (2000W) 3000VA (2700W)
INPUT Voltage nominal 120VAC
Voltage range -32% to +27% without use of battery
Frequency 50/60Hz auto-sensing
OUTPUT Voltage 120VAC nominal (110/115/127 selectable)
Waveform Pure sine wave
Transfer time (typical) 2–6ms
Efficiency Up to 99% ECO mode, 95% buck and boost mode
Harmonic distortion 2% @ 100% linear load; 5% @ 100% non-linear load
BATTERY Battery type Sealed, maintenance-free lead acid
Battery quantity/size (2) 12V 7AH (2) 12V 9AH (4) 12V 7AH (4) 12V 9AH (6) 12V 7AH (6) 12V 9AH
Charging current 1.5A max
Typical recharge 4 hours to 90%
PHYSICAL Dimensions (W x D x H) 17.2 x 15.1 x 3.5 in 17.2 x 18.9 x 3.5 in 17.2 x 23.6 x 3.5 in
Weight 29.3 lbs 30.5 lbs 44.7 lbs 47.4 lbs 61.7 lbs 67.1 lbs
Line cord 6 ft, 5–15P 6 ft, 5–15P 6 ft, 5–15P 6 ft, 5–20P 6 ft, 5–20P 6 ft, L5–30P
Receptacles (8) NEMA 5–15R (8) NEMA 5–15/20R (8) 5–15/20R or (6) 5–15/20R + L5-30R (V2)
OPTIONAL Model number N/A P90-BP48 P90-BP72
BATTERY PACKS Dimensions (W x D x H) N/A 17.2 x 18.9 x 3.5 in 17.2 x 23.6 x 3.5 in
Weight N/A 74.6 lbs 104.4 lbs
Battery N/A (8) 12V 9AH / 48V (12) 12V 9AH / 72V
ENVIRONMENT Operating temperature 32–104°F (0–40°C)
Audible noise < 45dBA
Altitude 11,500 ft above sea level
APPROVALS UL, cUL, RoHS, TAA compliant
WARRANTY 3 years electronics, 3 years battery warranty (USA and Canada)
COMMUNICATIONS INTERFACE RS-232, USB, EPO, intelligent slot for optional cards (Web/SNMP, Relay/dry contact, Modbus)
INCLUDED IN BOX Software CD, horizontal brackets, tower pedestals, user manual
AVAILABLE OPTIONS 5 year extended warranty, bypass distribution (XBDM), power distribution (XPDU), 4-post rail kit, 2-post shelf kit, wall mount bracket

 

  1. UPS Battery Packs

    [table colwidth=”75″]
    ,Model,Description,Unit Weight, Unit Dimensions
    ,P90-BP48,”48V Battery Pack for P80-1500, 2U”,74.6 lbs,17.2” x 19.9” x 3.5”
    ,P90-BP72,”72V Battery Pack for P80-2200, P80-3000, 2U”,104.4 lbs,17.2” x 24.6” x 3.5”
    [/table]

  2. Mounting Kits

    [table colwidth=”75″]
    ,Model,Description,Unit Weight, Unit Dimensions
    ,P90-RAIL,4-Post Rail Kit,5 lbs,3.8″ x 19.8″ x 2.8″
    ,XPC-2PRAIL,2-Post Rail Kit; Rated for 125 lbs,5 lbs,4.0” x 20.0” x 3.0”
    ,XPC-2POSTL,2-Post Shelf Kit; Rated for 150 lbs,9 lbs,21.5″ x 23.3″ x 3.5″
    ,P90-WMB,Wall Mount Bracket,5 lbs,4.0″ x 24.0″ x 4.0″
    ,P90-FRMB,”Front Rackmount Bracket for P90-1000, P90-1500, P90-2000″,1 lb,0.9″ x 2.0″ x 3.4″
    [/table]

  3. Connectivity

    [table colwidth=”75″]
    ,Model,Description,Unit Weight, Unit Dimensions
    ,SNMP-2PMINI,Two Port Internal SNMP Card,1 lb,7.25″ x 6″ x 2.5″
    ,SNMP-EMD,Environmental Monitoring Device,1 lb,7.25″ x 6″ x 2.5″
    ,MODBUS-IN,Modbus Card,1 lb,7.25″ x 6″ x 2.5″
    ,RELAY-MINI,General Relay Contacts with DB9 & Terminal Block Adapter,1 lb,7.25″ x 6″ x 2.5″
    [/table]

  4. Bypass Distribution Modules

    [table colwidth=”75″]
    ,Model,Description,Utility Input, Output Connections, UPS Connections, Unit Weight, Unit Dimensions
    ,XBDM-1015LV,”Bypass 15A/120VAC for use with P80-800, P80-1100, P80-1500″,”5–15P, 12ft”,”(6) 5–15R front, (4) 5–15R back”,5-15R,3.4 lbs,19” x 3.5” x 1.75”
    ,XBDM-1020LV,Bypass 20A/120VAC for use with P80-2200,”5–20P, 12ft”,”(6) 5–20R front, (4) 5–20R back”,5-20R,3.4 lbs,19” x 3.5” x 1.75”
    [/table]

  5. Power Distribution Units

    [table colwidth=”75″]
    ,Model,Description,Input Power Cord, Outlets, Unit Weight, Unit Dimensions
    ,XPD-1415HV,120V Basic Power Distribution Unit,”5–15P, 12ft”,(14) 5–15R,3.5 lbs,19.0″ x 3.5″ x 1.75″
    ,XPD-1420HV,120V Basic Power Distribution Unit,”L5–20P, 12ft or 5–20P with adapter”,(14) 5–25R,4.8 lbs,19.0″ x 3.5″ x 1.75″
    [/table]