5 kW · 208–240 V · Lithium UPS Comparison

J90 5kW vs APC Smart-UPS Ultra SRTL5KRM2UT

The Xtreme Power J90 5kW and the APC Smart-UPS Ultra SRTL5KRM2UT are both 5 kVA online lithium UPSs that fit 2U of rack space and plug into a 30 A L6-30 circuit. Runtime at full load is about the same. The J90 5kW delivers the full 5000 W at 208 V, is 5.7 in shallower, runs to 50 °C, and adds a 6-year warranty and TAA compliance. The APC has more outlets and a network card built in.

Xtreme Power
J90 5kW Lithium (J90-5k + 1 BPLi1U192A)
vs
APC by Schneider Electric
Smart-UPS Ultra SRTL5KRM2UT
Where the J90 5kW leads

What the J90 5kW brings

  • Substantially lower price than the APC
  • 5000 W at 208 V, vs 4900 W
  • 21.9 in deep, vs 27.6 in: fits shallow network and wall-mount racks
  • Lighter: 59.6 lbs with one lithium battery pack, vs 64.4 lbs
  • Rated to 50 °C (122 °F), vs 40 °C
  • LFP battery life up to 15 years in ideal conditions, vs 5 to 10 years
  • 6-year warranty, vs 5 years
  • TAA compliant, built in Taiwan
  • Wider input window at full load: 176 to 300 VAC
  • Choice of lithium or lower-cost lead-acid packs on the same UPS
Side-by-side

Side-by-side specifications at 5 kW

SpecificationXtreme Power J90 5kWAPC SRTL5KRM2UTAdvantage / consideration
TopologyOnline double conversion, 0 ms transferOnline double conversion, 0 ms transferEqual protection
Output at 208 V5000 VA / 5000 W4900 VA / 4900 WJ90 5kW – full 5 kW at 208 V
Output at 240 V5000 VA / 5000 W5000 VA / 5000 WEqual
Input connectionL6-30P, 10 ft cordL6-30P, 10 ft cordEqual
Input range at full load176 to 300 VAC187 to 275 VACJ90 5kW – wider input window
Output receptacles(2) L6-30R; optional XPD50 PDU or XBDM-J90A bypass PDU (rear-rail, front or vertical mount) adds (2) L6-20R and (2) L6-30R(2) L6-20R, (2) L6-30RAPC – outlets built in
Maintenance bypassInternal automatic bypass; optional rear-panel XBDM-J90A maintenance bypass PDU to swap the UPS without dropping the loadInternal bypass, automatic and manualJ90 5kW – hot-swap bypass option
Rack space with base battery2U: 1U UPS + 1U lithium battery pack2U, internal batteryEqual
Depth21.9 in27.6 inJ90 5kW – 5.7 in shallower
Weight with base battery59.6 lbs (25.4 UPS + 34.2 pack)64.4 lbsJ90 5kW – lighter
Battery chemistryLithium iron phosphate (LFP) with BMSLithium-ionBoth lithium
Runtime at full load5.2 min at 5000 W5 min at 4900 WEqual
Battery service lifeUp to 15 years in ideal conditions5 to 10 yearsJ90 5kW – longer battery life
Operating temperatureTo 50 °C (122 °F), full 5000 W with no derating0 to 40 °C (104 °F)J90 5kW – rated to 50 °C
Audible noise< 55 dBA55 dBAEqual
Network managementOptional SNMP-2PV3 card; USB and EPO standardNetwork management card included; USB, serial and EPOAPC – network card included
TAA complianceUPS, battery packs, XPD50 and XBDM-J90A TAA compliant, built in TaiwanNot listed by APC; resellers list it as not TAA compliantJ90 5kW – federal and GSA buyers
Standard warranty (USA)6 years electronics and battery5 yearsJ90 5kW – one more year
List priceSubstantially lower than the APC; contact sales for pricingMSRP $16,920J90 5kW – lower cost

J90 5kW Lithium (J90-5k with one BPLi1U192A battery pack) against the APC SRTL5KRM2UT with its internal battery. J90 5kW runtimes are calculated ahead of its March 2027 release; UL listing pending. TAA applies to the UPS, battery packs, XPD50 and XBDM-J90A; the optional XPD-IT60A isolation PDU is not TAA compliant. Runtimes vary with battery age, temperature and load. Specifications based on manufacturer documentation as of November 2026; confirm against current vendor data. APC and Smart-UPS are trademarks of Schneider Electric.

Where each fits

Choosing between them

Both protect a 5 kW load in 2U with about 5 minutes at full load. The J90 5kW leads on price, watts at 208 V, depth, weight, temperature, battery life, warranty and TAA compliance. The APC leads on built-in outlets and network management, and it is shipping today.

Choose the J90 5kW if you need

  • A lower price for 5 kW of lithium UPS
  • The full 5000 W at 208 V on an L6-30 circuit
  • A shallow rack: 21.9 in deep or less
  • Operation in warm closets or edge sites, to 50 °C
  • Long battery life and a 6-year warranty
  • TAA compliance for federal, state or GSA purchases
  • The option of lower-cost lead-acid packs
  • A maintenance bypass PDU to replace the UPS without a shutdown

The APC SRTL5KRM2UT may fit if you need

  • L6-20R and L6-30R outlets without an added PDU
  • A network management card in the box
  • A UPS before March 2027, or an existing APC fleet
Questions

Frequently asked questions

Is the J90 5kW an alternative to the APC Smart-UPS Ultra SRTL5KRM2UT?
Yes. Both are 5 kVA online lithium UPSs in 2U of rack space on an L6-30P cord. The J90 5kW delivers 5000 W at 208 V against 4900 W, is 5.7 in shallower, runs to 50 °C, carries a 6-year warranty and is TAA compliant. The APC has more outlets and a network card built in.
Why does the J90 5kW use a separate battery pack?
The 1U UPS carries the power electronics, and a 1U lithium battery pack carries the battery, so the two together fill the same 2U as the APC. Splitting them keeps both parts 21.9 in deep or less, lets you replace or add battery packs without touching the UPS, and lets you choose 2U lead-acid packs instead when first cost matters more than battery life.
How much runtime do I get?
At full load, about the same: 5.2 minutes from one J90 lithium pack at 5000 W, against 5 minutes from the APC at 4900 W. Adding a second pack to the J90 5kW gives about 11 minutes at 5 kW.
Is the J90 5kW TAA compliant?
Yes. The J90 5kW is built in Taiwan and is TAA compliant for federal, state and GSA purchases. APC does not list TAA compliance for the SRTL5KRM2UT, and resellers list it as not TAA compliant.
Can I replace the UPS without shutting down my equipment?
With the J90 5kW, yes. The optional XBDM-J90A maintenance bypass PDU sits between the wall receptacle and the UPS and carries the outlets. Turn its switch to Bypass, and the load runs on utility power while the UPS is serviced or swapped. The XBDM-J90A is built in Taiwan and TAA compliant. The APC SRTL5KRM2UT has an internal automatic and manual bypass, which keeps the load up during a UPS fault but not while the UPS itself is removed.
When can I buy the J90 5kW?
The J90 5kW ships in March 2027. Contact sales@xpcc.com to plan projects or quote ahead of release.

Quoting against an APC Smart-UPS Ultra?

Send us the load, voltage and runtime target. Our applications team will size the J90 5kW and its battery packs and send a quote ahead of release.