1000–3000 VA | 120V | 1U Online Double-Conversion UPS
High-density lithium rack UPS engineered for distributed IT, AV, telecommunications, and industrial infrastructure requiring conditioned power, compact deployment, and operational control at the rack level.
1U Rack · Online Double-Conversion · LiFePO₄ · 120V · 1–3kVA
Online double-conversion power protection in a 1U form factor with LiFePO₄ battery chemistry — up to 15-year service life, 50°C operation, individual outlet control, and external battery pack support on 2kVA and 3kVA models. The premium 1U lithium rack UPS for distributed IT, edge, AV, and industrial infrastructure.
The J90 continuously regenerates output power through the inverter — the connected load never operates on raw utility power. No transfer delay during a power event. Output power is clean, regulated, and isolated from upstream disturbances regardless of input conditions.
LiFePO₄ (lithium iron phosphate) batteries are rated for 3,000–5,000 discharge cycles and up to 15 years service life in ideal conditions. Across distributed deployments with 20 or 50 UPS units, eliminating the 3–5 year VRLA replacement cycle is a significant operational and cost advantage.
IDF closets, telecom rooms, and industrial enclosures regularly exceed 35–40°C. VRLA batteries specified at 25°C degrade rapidly above 30°C. The J90’s LiFePO₄ battery and thermal design support reliable operation to 50°C — covering the full range of real-world rack deployment environments.
Each outlet is individually switchable — a frozen switch, a hung firewall, a crashed controller can be power-cycled remotely without dispatching a technician. Across a campus with 20 IDF locations, that capability pays for itself after the first avoided service call.
The J90-2kLiD and J90-3kLiD support up to six EBP48 external LiFePO₄ battery packs for extended runtime — without the size and weight of VRLA battery cabinets. See the full runtime table below for exact values by load and pack count.
The J90 occupies 1U in a standard rack and mounts on any wall with the included bracket hardware. In IDF closets with wall-mount racks, the J90 installs clean without adapters or additional hardware — same unit, same bracket, either deployment.
J90 is the right choice when 1U density, individual outlet control, and lifecycle performance are priorities. When form factor is standard 2U rack/tower and lowest upfront cost matters, consider the P91Li. When depth is the constraint, consider the J60C.
Engineers evaluating 1U lithium rack UPS platforms commonly compare the J90 against APC Smart-UPS Ultra, Eaton 9PX Lithium, Vertiv Liebert GXT5, and Middle Atlantic NexSys. The primary differentiators are form factor, topology, individual outlet control, temperature rating, and external runtime capability.
| Feature | J90 | APC Smart-UPS Ultra | Eaton 9PX Lithium | Vertiv GXT5 Li | Middle Atlantic NexSys |
|---|---|---|---|---|---|
| Form factor | 1U | 1U | 2U | 2U | 2U |
| Topology | Online double-conversion | Online double-conversion | Online double-conversion | Online double-conversion | Online double-conversion |
| Battery chemistry | LiFePO₄ | Lithium-ion | Lithium-ion / LFP | Lithium-ion | LiFePO₄ |
| Individual outlet control | Yes — per outlet | No | No | No | Select models |
| External battery support | Yes — 2kVA and 3kVA | Yes | Yes | Yes | No |
| Max operating temp | 50°C | 40°C typical | 40°C typical | 40°C typical | 40°C typical |
| Wall mount | Yes — brackets included | No | No | No | Optional |
| TAA compliant | Yes | No | No | No | No |
| Warranty | 6 years | 5 years | 3 years | 2 years | 3 years |
| Attribute | J90 Series |
|---|---|
| Topology | Online double-conversion |
| Capacity | 1000VA / 1500VA / 2000VA / 3000VA |
| Input voltage | 120V AC |
| Output voltage | 120V AC |
| Frequency | 50/60 Hz auto-sensing |
| Efficiency | Online mode — up to 88% (1kVA) · 91% (1.5kVA) · 92% (2kVA) · 94.5% (3kVA) · ECO mode >96% (all models) |
| Battery chemistry | LiFePO₄ (lithium iron phosphate) |
| Battery service life | Up to 15 years — ideal conditions · 3,000–5,000 cycles |
| Operating temperature | Up to 50°C (122°F) · derating may apply above 40°C |
| Form factor | 1U rackmount |
| Mounting | Rack or wall — brackets included standard |
| Outlet control | Individual switchable outlets |
| Extended runtime | External EBP48 packs — 2kVA and 3kVA models (up to 6 packs) |
| Monitoring | Optional SNMP/Web card |
| Communication | USB · RS-232 · optional SNMP |
| Warranty | 6 years — USA and Canada · 2 years above 40°C continuous |
| Certifications | UL-1778 · cUL · UN38.3 · RoHS · FCC Class A · TAA compliant |
Runtime values are estimated minutes at the load shown. Internal battery only for 1kVA and 1.5kVA models. The 2kVA and 3kVA models support up to six EBP48 external battery packs. Actual runtime varies by battery age, temperature, and load profile.
| Model / Configuration | 100VA 90W |
150VA 135W |
200VA 180W |
300VA 270W |
400VA 360W |
600VA 540W |
800VA 720W |
1000VA 900W |
1200VA 1080W |
1400VA 1260W |
1500VA 1350W |
1600VA 1440W |
1800VA 1620W |
2000VA 1800W |
2333VA 2100W |
2666VA 2400W |
3000VA 2700W |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| J90-1kLiD | 53 | 35 | 30 | 21 | 16 | 11 | 8.1 | 6.5 | — | — | — | — | — | — | — | — | — |
| J90-1.5kLiD | — | 59 | 44 | 33 | 24 | 17 | 13 | 10.5 | 8.8 | 7.5 | 7 | — | — | — | — | — | — |
| J90-2kLiD | — | — | 54 | 36 | 28 | 20 | 15 | 12 | 10 | 8.6 | 8 | 7.5 | 6.7 | 6 | — | — | — |
| J90-2kLiD + 1 EBP48 | — | — | 270 | 180 | 142 | 100 | 75 | 60 | 50 | 43 | 40 | 38 | 33 | 30 | — | — | — |
| J90-2kLiD + 2 EBP48 | — | — | 486 | 324 | 255 | 180 | 135 | 108 | 90 | 77 | 72 | 68 | 60 | 54 | — | — | — |
| J90-2kLiD + 3 EBP48 | — | — | 703 | 468 | 368 | 260 | 195 | 156 | 130 | 111 | 104 | 98 | 87 | 78 | — | — | — |
| J90-2kLiD + 4 EBP48 | — | — | 919 | 613 | 481 | 340 | 255 | 204 | 170 | 146 | 136 | 128 | 113 | 102 | — | — | — |
| J90-2kLiD + 5 EBP48 | — | — | 1135 | 757 | 594 | 420 | 315 | 252 | 210 | 180 | 168 | 158 | 140 | 126 | — | — | — |
| J90-2kLiD + 6 EBP48 | — | — | 1351 | 901 | 708 | 500 | 375 | 300 | 250 | 214 | 200 | 188 | 167 | 150 | — | — | — |
| J90-3kLiD | — | — | — | 38 | 28 | 20 | 15 | 12 | 10 | 8.6 | 8 | 7.5 | 6.7 | 6 | 5.1 | 4.5 | 4 |
| J90-3kLiD + 1 EBP48 | — | — | — | 189 | 142 | 98 | 73 | 60 | 50 | 43 | 40 | 38 | 33 | 30 | 26 | 23 | 20 |
| J90-3kLiD + 2 EBP48 | — | — | — | 341 | 256 | 176 | 132 | 108 | 90 | 77 | 72 | 68 | 60 | 54 | 46 | 41 | 36 |
| J90-3kLiD + 3 EBP48 | — | — | — | 492 | 369 | 254 | 191 | 156 | 130 | 111 | 104 | 98 | 87 | 78 | 67 | 59 | 52 |
| J90-3kLiD + 4 EBP48 | — | — | — | 644 | 483 | 333 | 249 | 204 | 170 | 146 | 136 | 128 | 113 | 102 | 87 | 77 | 68 |
| J90-3kLiD + 5 EBP48 | — | — | — | 795 | 596 | 411 | 308 | 252 | 210 | 180 | 168 | 158 | 140 | 126 | 108 | 95 | 84 |
| J90-3kLiD + 6 EBP48 | — | — | — | 946 | 710 | 489 | 367 | 300 | 250 | 214 | 200 | 188 | 167 | 150 | 129 | 113 | 100 |
All values in estimated minutes. Actual runtime varies by battery age, ambient temperature, and load profile. Download runtime PDF → · UPS sizing tool →
The J90-1.5kLiX adds EBP48 external battery pack compatibility to the 1.5kVA model — combining the J90’s online double-conversion topology, switchable outlets, LiFePO₄ chemistry, and 50°C operation with the extended runtime flexibility currently available only on the 2kVA and 3kVA models. Not yet available — check the product page for availability.
Sizing, runtime planning, EBP48 pack configuration, TAA procurement support, and deployment guidance for distributed and edge infrastructure.