1500VA 120V UPS Systems for 15A Circuits

1500VA is the maximum practical UPS size for a standard 120V 15A circuit — the 80% continuous load rule limits a 15A breaker to 12A continuous, which is 1,440W at 120V. Seven platforms cover this capacity across line-interactive, online, and lithium topologies.

Circuit 120V · 15A
Plug type NEMA 5-15P
Max continuous (80%) 12A · 1,440W
Max UPS size 1500VA
Need a larger UPS? A dedicated 20A circuit supports up to 2000VA. Circuit sizing guide →
All platforms

Seven platforms — find the right one for your application

The difference between these platforms is topology, battery chemistry, form factor, and runtime capability — not capacity. All are 1500VA at 120V on a standard 5-15P plug.

Line-interactive · Lead acid
S71-1500
S71 Series · Tower
Entry-level protection for non-critical loads where lowest upfront cost is the priority.

Line-interactive topology with AVR voltage regulation. Tower form factor. The right choice for basic office equipment, POS terminals, and non-critical loads where online double-conversion is not required and budget is the primary constraint.

TopologyLine-interactive
BatteryVRLA lead acid
Form factorTower
Extended runtimeNo
View S71 →
Coming soon
V70-1500
V70 Series · Short depth
Short-depth line-interactive for wall-mounted cabinets, AV systems, and shallow rack deployments.

Designed for shallow racks, wall-mount cabinets, and AV infrastructure where standard rack UPS depth is a constraint. Line-interactive topology. Not yet available — check product page for availability.

TopologyLine-interactive
BatteryVRLA lead acid
Form factorShort depth · rack/wall
StatusComing soon
Check availability →
Line-interactive · Lead acid
P80-1500
P80 Series · Rack/Tower
Cost-effective rack/tower UPS with external battery expansion capability for extended runtime.

Line-interactive topology in a convertible rack/tower form factor. Supports external battery packs for extended runtime — useful where 10–15 minutes isn’t enough but online topology isn’t required. Good value for IT, retail, and light industrial at this capacity.

TopologyLine-interactive
BatteryVRLA lead acid
Form factorRack or tower
Extended runtimeYes — external pack
View P80 →
Online · Lead acid
T91-1500
T91 Series · Tower
Online double-conversion in a tower form factor with external battery expansion for extended runtime.

Online double-conversion — zero transfer time, continuous power conditioning. Tower form factor for locations where a rack isn’t available. External battery packs extend runtime beyond what the internal battery provides. Right choice for sensitive equipment in a tower deployment.

TopologyOnline double-conversion
BatteryVRLA lead acid
Form factorTower
Extended runtimeYes — external pack
View T91 →
Online · Lead acid
P91-1500
P91 Series · Rack/Tower
Online double-conversion in rack/tower with external battery expansion — the standard for network infrastructure.

Online double-conversion in a convertible rack/tower form factor. External battery packs extend runtime. The standard rackmount online UPS for network infrastructure, AV systems, and distributed IT at this capacity — where online topology is required but lithium isn’t specified.

TopologyOnline double-conversion
BatteryVRLA lead acid
Form factorRack or tower
Extended runtimeYes — external pack
View P91 →
Online · Lithium LiFePO₄
P91Li-1500
P91Li Series · Rack/Tower
Online double-conversion with LiFePO₄ battery — for deployments where battery replacement is a burden.

Same form factor and topology as the P91 with LiFePO₄ battery chemistry — up to 15-year service life in ideal conditions, 3,000–5,000 cycles, 50°C operation. The right choice when the P91’s performance profile is right but battery replacement across distributed sites is operationally unacceptable.

TopologyOnline double-conversion
BatteryLiFePO₄ lithium
Form factorRack or tower
Max temp50°C
View P91Li →
Online · Lithium LiFePO₄
J90-1.5kLiD
J90 Series · 1U Rack · 1500VA
1U online lithium UPS with switchable outlets and remote reboot — the premium choice for network racks.

Online double-conversion in a 1U form factor with switchable outlets for remote reboot of individual devices. LiFePO₄ battery — no routine replacement. High-temperature operation to 50°C for non-conditioned IDF closets. Internal battery only — no external battery pack support at this capacity. See J90-1.5kLiX below for extended runtime capability.

TopologyOnline double-conversion
BatteryLiFePO₄ lithium
Form factor1U rack
Extended runtimeNo — internal battery only
View J90 →
Lithium · Coming soon
J90-1.5kLiX
J90 DX Series · 1U Rack · 1500VA
Extended runtime version of the J90 — 1U lithium with external battery pack support.

The X variant of the J90 1.5kVA adds compatibility with external battery packs for significantly extended runtime — combining the J90’s online double-conversion, switchable outlets, LiFePO₄ chemistry, and 50°C operation with the runtime flexibility previously only available on lead acid platforms. Not yet available — check product page for availability.

TopologyOnline double-conversion
BatteryLiFePO₄ lithium
Form factor1U rack
Extended runtimeYes — external pack
Check availability →
Platform comparison

All 1500VA 120V platforms compared

Platform Topology Battery Form factor Ext. runtime Best for
S71-1500 Line-interactive Lead acid Tower No Basic office, POS, non-critical
V70-1500 Line-interactive Lead acid Short depth No Shallow racks, AV, wall-mount Coming soon
P80-1500 Line-interactive Lead acid Rack/tower Yes Cost-effective IT, retail, extended runtime
T91-1500 Online Lead acid Tower Yes Online protection, tower deployment
P91-1500 Online Lead acid Rack/tower Yes Network, AV, distributed IT
P91Li-1500 Online Lithium Rack/tower No Long-life, distributed, high-temp
J90-1.5kLiD Online Lithium 1U rack No Network racks, remote reboot, IDF closets
J90-1.5kLiX Online Lithium 1U rack Yes Coming soon Network racks requiring extended runtime with lithium
Runtime guidance

Typical runtime at 1500VA · 120V

Runtime depends on actual load — not UPS capacity. A 1500VA UPS running a 400W load runs significantly longer than the same UPS at 900W. These ranges reflect typical deployments across the platform lineup.

Approximate runtime by load — internal battery only
300–400W load 20–40 minutes typical
600W load 10–20 minutes typical
900W load 5–15 minutes typical
Extended runtime models P80, T91, P91 — external battery packs · J90-1.5kLiX — external pack (coming soon)
Runtime varies by model, battery age, temperature, and load profile. Use the sizing tool for model-specific calculations.
Calculate exact runtime for your load and battery configuration using the UPS sizing tool.
UPS sizing tool →