10 kVA / 10 kW · 208–240 VAC · Online Double-Conversion Rack UPS Comparison

P91-10K vs Vertiv Liebert GXT5-10KHVRT5UXLN

The Xtreme Power P91-10K (paired with the BPXR3U240A pack) and Vertiv Liebert GXT5-10KHVRT5UXLN are both true online double-conversion VRLA UPS delivering full 10 kVA / 10 kW at unity PF. The P91-10K differentiates on longer baseline runtime, modular bypass/distribution, a lower rack footprint, and TAA.

Xtreme Power
P91-10K + BPXR3U240A
vs
Vertiv
Liebert GXT5-10KHVRT5UXLN
Where the P91-10K + BPXR3U240A leads

What the P91-10K brings

  • Longer baseline runtime (6 min vs 2 min @ 10 kW)
  • Lower rack footprint (5U vs 6U)
  • Optional XBDM modular bypass & distribution
  • Built-in TAA compliance for federal procurement
  • Scalable runtime with BPXR battery modules
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-10K + BPXR3U240AVertiv Liebert GXT5-10KHVRT5UXLNAdvantage
UPS capacity10 kVA / 10 kW10 kVA / 10 kWEquivalent usable power
TopologyOnline double-conversionOnline double-conversionEquivalent premium protection
Output voltage208/220/230/240 VAC208/220/230/240 VACAligned voltage support
System runtime (full load)6 min @ 10 kW2 min @ 10 kWP91 – longer baseline runtime
Optional external battery cabinetsYes (BPXR series)Yes (Vertiv EBCs)Both support runtime scaling
Input / output architectureHardwired or optional XBDM modular bypass & distributionHardwired input only; fixed output receptaclesP91 – greater flexibility & serviceability
Rack height5U total (2U UPS + 3U battery)6U UPSP91 – lower rack footprint
Warranty3-yr electronics / 3-yr battery3-yr electronics / 3-yr batteryEquivalent coverage
Compliance / listingsUL1778, cUL, FCC, CE, RoHS, TAAUL1778, c-UL, CSA, FCC Class AP91 – adds TAA
TAA complianceYesNoP91 – federal procurement

Specifications from Xtreme Power’s supplied P91-10K vs Vertiv GXT5-10KHVRT5UXLN comparison; based on publicly available manufacturer data. Both deliver full 10 kW at unity PF; the P91-10K (shown with a BPXR3U240A pack) provides longer baseline runtime in a lower 5U footprint vs the Vertiv’s 6U.

Where each fits

Choosing between them

Both deliver full 10 kW at unity PF with equivalent warranty. The P91-10K leads on baseline runtime, rack footprint (5U vs 6U), modular bypass/distribution, and TAA; the Vertiv HVRT suits Vertiv-standardized sites favoring a single integrated chassis.

Choose the P91-10K + BPXR3U240A if you need

  • Federally funded / TAA-restricted procurement
  • Longer baseline runtime without external cabinets
  • Lower total rack footprint for high-density environments
  • Modular bypass and power distribution (XBDM)

The Liebert GXT5-10KHVRT5UXLN may fit if you need

  • A single integrated UPS chassis
  • Alignment with an existing Vertiv ecosystem
  • Non-TAA commercial deployments with minimal runtime needs

Specifying a centralized 5-10 kVA online UPS?