5 kVA / 5 kW · 208–240 VAC · Online Double-Conversion Rack UPS Comparison

P91-5K vs Vertiv Liebert GXT5-5KL630RT3UXLN

The Xtreme Power P91-5K (with the BPXR2U240A battery pack) and Vertiv Liebert GXT5-5KL630RT3UXLN are online double-conversion UPS for mission-critical IT and infrastructure loads, both on VRLA batteries. The P91-5K configuration prioritizes longer baseline runtime, higher usable watts, modular bypass and distribution (XBDM), and built-in TAA compliance; the GXT5 emphasizes integrated internal batteries in a compact UPS-only chassis.

Xtreme Power
P91-5K
vs
Vertiv
Liebert GXT5-5KL630RT3UXLN
Where the P91-5K leads

What the P91-5K brings

  • Higher usable watt capacity (5 kW vs 4.6 kW)
  • Longer baseline runtime at full load (7 min vs 4.8 min)
  • Optional XBDM modular bypass and distribution
  • Runtime scaling via BPXR battery options
  • TAA compliance for federal procurement
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-5K + BPXR2U240AVertiv Liebert GXT5-5KL630RT3UXLNAdvantage
Capacity5 kVA / 5 kW4.9 kVA / 4.6 kWP91 – higher usable watts (5 vs 4.6 kW)
TopologyOnline double conversionOnline double conversionEquivalent protection
Output voltage208 / 220 / 230 / 240 VAC208 / 220 / 230 / 240 VACAligned voltage support
Runtime (full load)7 min at 5 kW4.8 min at 4.6 kWP91 – longer runtime at higher load
External battery cabinetsYes (BPXR series)Yes (Vertiv EBCs)Both scale runtime
Input / output architectureHardwired or optional XBDM modular bypass & distributionL6-30P input; fixed receptacle setP91 – modular bypass and distribution
Rack height4U total (2U UPS + 2U battery)3U UPSVertiv 1U shorter; P91 trades 1U for runtime
Battery technologyVRLAVRLAComparable chemistry
Compliance / listingsUL1778, cUL, FCC, CE, RoHS, TAAUL1778, c-UL, CSA, FCC Class ABoth UL1778 listed
TAA complianceYesNoP91 – federal procurement
Warranty3 yr electronics / 3 yr battery3 yr electronics / 3 yr batteryAligned coverage

Specifications from Xtreme Power’s P91-5K vs Vertiv GXT5 comparison; confirm against current vendor documentation. P91-5K runtime shown with the BPXR2U240A battery pack.

Where each fits

Choosing between them

The P91-5K leads on usable watts, runtime, modular bypass and distribution, and TAA; the GXT5 offers a more compact 3U UPS-only chassis for Vertiv-standardized, non-regulated sites.

Choose the P91-5K if you need

  • Higher usable watt capacity (5 kW vs 4.6 kW)
  • Longer baseline runtime at full load
  • Modular bypass and distribution (XBDM) for service and expansion
  • Built-in TAA compliance for government, education, and public-sector
  • Flexible runtime scaling with BPXR options

The Liebert GXT5 may fit if you need

  • A more compact UPS-only footprint (3U)
  • Alignment with an existing Vertiv ecosystem
  • A non-regulated deployment with modest runtime needs
Questions

Frequently asked questions

What competes with the Vertiv Liebert GXT5-5KL630RT3UXLN?

The Xtreme Power P91-5K (with the BPXR2U240A pack) is a common alternative, delivering higher usable watts (5 kW vs 4.6 kW) and longer baseline runtime with optional XBDM modular bypass and distribution.

Why does the P91-5K show higher watts at the same VA class?

The P91-5K is rated at unity power factor (5 kVA / 5 kW), while the GXT5 delivers 4.6 kW from 4.9 kVA. Since modern IT runs near unity PF, the P91’s full 5 kW is usable real power.

Why is the P91-5K 4U when the GXT5 is 3U?

The P91-5K’s 4U includes a dedicated 2U battery pack that delivers longer baseline runtime, about 7 minutes at 5 kW vs 4.8 minutes at 4.6 kW. The extra 1U buys runtime.

Is the P91-5K TAA compliant?

Yes. The P91-5K is UL1778 listed and TAA compliant for federal, education, and public-sector procurement; the GXT5-5KL630RT3UXLN is not TAA listed.

Specifying a 5-10 kVA online UPS?

Xtreme Power supports specification, runtime sizing, and design-in for enterprise IT, telecom, healthcare, education, and public-sector racks.