5 kVA / 5 kW · 208–240 VAC · Online Double-Conversion Rack UPS Comparison

P91-5K vs Dell-APC Smart-UPS On-Line DLRT5KRMXLT

The Xtreme Power P91-5K (with the BPXR2U240A battery pack) and Dell-APC Smart-UPS On-Line DLRT5KRMXLT are online double-conversion UPS for mission-critical IT and infrastructure loads, both on VRLA batteries. The P91-5K configuration prioritizes higher usable watt output, longer baseline runtime, modular bypass and distribution (XBDM), and built-in TAA compliance; the Dell-APC unit emphasizes integrated management in a compact 3U UPS-only chassis.

Xtreme Power
P91-5K
vs
Dell-APC
Smart-UPS On-Line DLRT5KRMXLT
Where the P91-5K leads

What the P91-5K brings

  • Higher usable watt output (5 kW vs 4.25 kW)
  • Longer baseline runtime at full load (7 min vs 4.4 min)
  • Optional XBDM modular bypass and distribution
  • Runtime scaling via BPXR battery options
  • TAA compliance for federal procurement
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-5K + BPXR2U240ADell-APC DLRT5KRMXLTAdvantage
Capacity5 kVA / 5 kW5 kVA / 4.25 kWP91 – higher usable watts (5 vs 4.25 kW)
TopologyOnline double conversionOnline double conversionEquivalent protection
Output voltage208 / 220 / 230 / 240 VAC208 / 230 / 240 VACComparable (P91 also lists 220 V)
Runtime (full load)7 min at 5 kW4.4 min at 4.25 kWP91 – longer runtime at higher load
External battery cabinetsYes (BPXR series)YesBoth scale runtime
Input / output architectureHardwired or optional XBDM modular bypass & distributionL6-30P input; fixed receptacle setP91 – modular bypass and distribution
Rack height4U total (2U UPS + 2U battery)3U UPSDell-APC 1U shorter; P91 trades 1U for runtime
Battery technologyVRLAVRLAComparable chemistry
Compliance / listingsUL1778, cUL, FCC, CE, RoHS, TAAUL1778, cUL, FCC Part 15 A, ENERGY STARBoth UL1778 listed
TAA complianceYesNoP91 – federal procurement
Warranty3 yr electronics / 3 yr battery3 yr electronics / 3 yr batteryEquivalent coverage

Specifications from Xtreme Power’s P91-5K vs Dell-APC DLRT5KRMXLT comparison; confirm against current vendor documentation. P91-5K runtime shown with the BPXR2U240A battery pack.

Where each fits

Choosing between them

The P91-5K leads on usable watts, runtime, modular bypass, and TAA; the DLRT5KRMXLT offers a compact 3U UPS-only chassis with integrated management for Dell-APC-standardized, non-regulated sites.

Choose the P91-5K if you need

  • Higher usable watt output (5 kW vs 4.25 kW)
  • Longer baseline runtime at full load
  • Modular bypass and distribution (XBDM) for service and expansion
  • Built-in TAA compliance for government, education, and public-sector
  • Flexible runtime scaling with BPXR options

The DLRT5KRMXLT may fit if you need

  • A more compact 3U UPS-only design
  • Alignment with an existing Dell-APC ecosystem
  • A non-regulated deployment with modest runtime needs
Questions

Frequently asked questions

What competes with the Dell-APC Smart-UPS On-Line DLRT5KRMXLT?

The Xtreme Power P91-5K is commonly evaluated as an alternative, delivering higher usable watts (5 kW vs 4.25 kW) and longer baseline runtime with optional XBDM modular bypass and distribution.

Why does the P91-5K deliver more watts at the same 5 kVA rating?

The P91-5K is rated at unity power factor (5 kW from 5 kVA), while the DLRT5KRMXLT delivers 4.25 kW from 5 kVA, a 0.85 power factor. Because modern IT runs near unity PF, the P91 supports more real equipment load from the same VA class.

Why is the P91-5K 4U when the Dell-APC unit is 3U?

The P91-5K’s 4U includes a 2U battery pack for longer baseline runtime, about 7 minutes at 5 kW vs 4.4 minutes at 4.25 kW. The extra 1U buys runtime.

Is the P91-5K TAA compliant?

Yes. The P91-5K is UL1778 listed and TAA compliant for federal and public-sector procurement; the DLRT5KRMXLT is not TAA listed.

Specifying a 5-10 kVA online UPS?

Xtreme Power supports specification, runtime sizing, and design-in for enterprise IT, telecom, healthcare, education, and public-sector racks.