M90S-6S (12 kW) vs Vertiv Liebert APS AS5B0NCVGNNXLKB

The Xtreme Power M90S-6S, configured for 12 kW usable output, and the Vertiv Liebert APS AS5B0NCVGNNXLKB are modular online double-conversion UPS for mission-critical IT, network, and edge-infrastructure loads. Both support modular growth and redundancy; the M90S-6S delivers higher usable power at unity power factor, longer baseline runtime, and greater scalability headroom — better suited to higher-density 12 kW deployments.

Xtreme Power
M90S-6S
vs
Vertiv
Liebert APS AS5B0NCVGNNXLKB
Where the M90S-6S leads

Where the M90S-6S leads at 12 kW

  • About 33% more usable kW at base rating — 12 kW (unity PF) vs 9 kW.
  • Longer baseline internal runtime (about 9 min vs 5 min), reducing reliance on external battery modules.
  • Greater growth and redundancy headroom — scales to 24 kVA (18 kVA N+1) vs 15 kVA.
  • Integrated maintenance bypass, module-level diagnostics, TAA compliance, and a 3-year warranty.
Side-by-side

12 kW modular UPS, side by side

SpecificationXtreme Power M90S-6SVertiv Liebert APS AS5B0NCVGNNXLKBAdvantage
Usable output capacity12 kVA / 12 kW (unity PF)10 kVA / 9 kWAbout 33% more usable kW at base rating
TopologyOnline double-conversionOnline double-conversionEquivalent protection
Internal runtime (full load, base)About 9 min @ 12 kWAbout 5 min @ 9 kWLonger baseline runtime without EBMs
Scalability / redundancyScales to 24 kVA, or 18 kVA N+1Scales to 15 kVA (N+1)Greater growth and redundancy headroom
Maintenance bypassStandard, integratedOptional externalReduced accessories and installation cost
Display & diagnosticsChassis LCD + module-level displaysChassis-level LCDMore granular local visibility
CertificationsUL, cUL, TAA compliantUL, cULTAA compliance for regulated markets
Warranty3 years (electronics & batteries)2-year limitedLonger standard coverage

Capacity figures show usable watts: the M90S delivers unity power factor (kVA = kW), while the Vertiv APS is rated at a lower power factor. The M90S is UL / cUL listed and TAA compliant; the Vertiv APS is UL / cUL. Runtime figures are base-battery, full-load estimates from manufacturer documentation.

Where each fits

Choosing between them

Both are modular online double-conversion UPS. The M90S leads on unity-PF usable kW, longer baseline runtime, scalability headroom, integrated bypass, module-level diagnostics, TAA compliance, and warranty; the Vertiv APS fits where it is already the standard or where the load sits at or below its usable rating.

Choose the M90S-6S if you need

  • Full 12 kW usable output without oversizing
  • Longer runtime with base batteries
  • Growth headroom beyond 15 kVA within one platform
  • Integrated maintenance bypass to simplify installation
  • TAA-compliant solutions for regulated environments

The Liebert APS AS5B0NCVGNNXLKB may fit if you need

  • Alignment with an existing Vertiv APS ecosystem
  • A solution sized for 9 kW or less usable output
  • External bypass and EBMs as part of a predefined architecture

Replacing a Symmetra LX or planning modular UPS?

Xtreme Power supports modular UPS sizing, N+1 redundancy planning, and smooth migration from legacy Symmetra LX systems across enterprise, healthcare, industrial, and public-sector infrastructure.