6–48 kW Modular Online UPS · Single-Phase · Competitive Comparisons

M90S modular UPS comparisons

The Xtreme Power M90S is a modular online double-conversion single-phase UPS family — 2S, 4S, 6S, and 12S — scaling from 6 kW to 48 kW with hot-swappable power and battery modules, unity power factor (kVA = kW), N+1 redundancy, integral maintenance bypass, and TAA compliance. This hub is the reference for evaluating the M90S against the modular and high-capacity single-phase platforms it most often replaces: APC Symmetra LX, Eaton 9PXM, Vertiv Liebert APS, Toshiba 3000 SP, and RoseWater Energy HUB — each in a capacity-matched, head-to-head comparison.

Topology
Modular online DC
Capacity
6–48 kW
Power factor
1.0 (unity)
Procurement
TAA compliant
Deployment architecture

Modular single-phase UPS deployment

Modular UPS platforms let capacity, redundancy, and runtime scale incrementally within one system — adding 6 kW power modules as load grows and configuring N+1 redundancy without deploying multiple separate UPS. The M90S targets single-phase environments needing centralized protection from a few kW up to 48 kW, where three-phase utility is unavailable, impractical, or not cost-effective. Selection turns on usable power factor, module size, efficiency, runtime, maintenance bypass, footprint, and TAA-compliant procurement.

Commercial electrical roomsTelecom & cell sitesWhole-home & large residentialLight industrialDistributed computeRemote & off-grid
M90S series model guide

Four platforms from 6 to 48 kW

ModelCapacitySlots / form factorTypical deployment
M90S-2S6 kW2-slot · rack-mountableEntry modular, single rack
M90S-4S6–12 kW4-slot · rack-mountableScalable rack and edge sites
M90S-6S6–24 kW6-slot · rack-mountableCore modular, electrical rooms
M90S-12S6–48 kW12-slot · floor-standing, hardwiredHigh-capacity centralized single-phase

Shared platform characteristics: online double-conversion topology, unity power factor (kVA = kW), hot-swappable power and battery modules, N+1 redundancy, integral maintenance bypass, up to 98% ECO-mode efficiency, UL-1778 (TUV) / cUL listing, TAA compliance, and a 3-year electronics and battery warranty (USA & Canada). The 2S, 4S, and 6S are rack-mountable with the M90S-RMK kit; the 12S is floor-standing and hardwired.

Online double-conversionUnity PF (kVA=kW)Hot-swap modulesN+1 redundancyIntegral bypassTAA compliant
Comparison matrix

M90S competitive comparisons by competitor

Each competitor links to a detailed, capacity-matched comparison against the corresponding M90S model. The “where the M90S leads” column summarizes the M90S’s primary advantages; competitor strengths — footprint, native rack/tower conversion, onsite warranty, TAA parity — are documented honestly on each page.

APC Symmetra LX
M90S modelCompetitorCapacityWhere the M90S leadsDetailed comparison
M90S-2SAPC Symmetra LX (SYA8K8RMP)6–8 kVAUnity PF vs 0.80, up to 98% efficiency, TAA; Symmetra LX discontinuedFull comparison →
M90S-4SAPC Symmetra LX (SYA12K16RMP)12 kVAMore usable kW at unity PF, 98% efficiency, current TAA platformFull comparison →
M90S-6SAPC Symmetra LX (SYA16K16RMP)16–18 kVAUnity PF usable kW, TAA, supported platform (APC more compact at 19U)Full comparison →
Eaton 9PXM
M90S modelCompetitorCapacityWhere the M90S leadsDetailed comparison
M90S-4SEaton 9PXM (9PXM8S12K)12 kVAUnity PF vs 0.90, longer internal runtime, integral maintenance bypassFull comparison →
M90S-6SEaton 9PXM (9PXM12S16K)16–18 kVAUnity PF usable kW, module-level diagnostics (Eaton TAA, rack/tower native)Full comparison →
M90S-6S (18 kW)Eaton 9PXM (9PXM12S20K)18 kVALarger 6 kW blocks, integral bypass (usable kW parity at 18 kW)Full comparison →
Vertiv Liebert APS
M90S modelCompetitorCapacityWhere the M90S leadsDetailed comparison
M90S-6S (12 kW)Vertiv Liebert APS (AS5B0NCVGNNXLKB)12 kWUnity PF, battery energy, TAA complianceFull comparison →
M90S-6S (18 kW)Vertiv Liebert APS (AS6C0NCWGNNXLKB)18 kWUnity PF usable kW, runtime, TAA complianceFull comparison →
Toshiba 3000 SP
M90S modelCompetitorCapacityWhere the M90S leadsDetailed comparison
M90S-6S (12 kW)Toshiba 3000 SP12 kWSmaller cabinet, scalable capacity (unity PF / output parity)Full comparison →
M90S-6S (18 kW)Toshiba 3000 SP18 kWSmaller footprint, modular growth (Toshiba onsite warranty)Full comparison →
RoseWater Energy HUB
M90S modelCompetitorCapacityWhere the M90S leadsDetailed comparison
M90S-12SRoseWater Energy HUB2020 kW classModular 6–48 kW, fully rated rectifier, 98% ECO, TAA (HUB onsite warranty)Full comparison →
M90S-12SRoseWater Energy HUB4040 kW classModular scalability, one cabinet vs two, fully rated rectifier, TAAFull comparison →

Competitor figures are taken from Xtreme Power’s published comparison datasheets; confirm per SKU against current vendor documentation. The APC Symmetra LX is discontinued. The Eaton 9PXM is TAA-compliant and natively rack/tower-convertible, with usable-kW parity at 18 kW. The Toshiba 3000 SP matches the M90S on unity power factor and rated output and includes onsite warranty. The RoseWater HUB includes onsite service in its warranty, and the HUB20 has a marginally smaller footprint than the M90S-12S.

Product pages & step-up

M90S platforms and adjacent systems

Core modular
M90S-6S

Six-slot modular online UPS, 6–24 kW, with unity power factor and N+1 redundancy for electrical rooms and racks.

View the M90S-6S →
High-capacity modular
M90S-12S

Twelve-slot hardwired platform scaling to 48 kW — centralized single-phase protection where three-phase is unavailable.

View the M90S-12S →
Three-phase facility
Li90

Lithium three-phase facility UPS for deployments that exceed practical single-phase capacity limits.

View the Li90 →

Planning a modular UPS deployment?

Xtreme Power supports module configuration, N+1 redundancy planning, runtime sizing, single-phase vs three-phase strategy, and competitive replacement across commercial, telecom, industrial, and residential infrastructure.