30 kVA / 30 kW · 208/120 V · Three-Phase Online UPS

Li90-30k vs Vertiv EXS-V 30 kVA

The Xtreme Power Li90-30k and the Vertiv VM-class EXS-V (EXSV-30KN) are both online double-conversion three-phase UPS for healthcare, industrial, commercial, and data-center infrastructure. The Vertiv VM-class is a compact standalone UPS typically deployed with VRLA batteries; the Li90 integrates lithium modules in a compact cabinet to raise power density, cut lifecycle maintenance, and simplify long-term infrastructure planning.

Xtreme Power
Li90-30k
vs
Vertiv
EXS-V 30 kVA (EXSV-30KN)
Key differentiators at a glance

Why engineers evaluate the Li90

  • Integrated lithium (LiFePO₄) battery modules — no external cabinets
  • Up to 15-year battery design life
  • Online efficiency of 94.5%
  • Compact 12.6-inch cabinet — higher power density
  • Greater internal runtime without external battery cabinets
  • Roughly one-third the installed weight
  • Designed for retrofit modernization
Side-by-side

30 kVA / 30 kW three-phase UPS comparison

FeatureXtreme Power Li90-30kVertiv EXS-V 30 kVAAdvantage
UPS architectureLithium-integrated compact standaloneCompact standalone three-phaseBoth compact standalone
Rated capacity30 kVA / 30 kW30 kVA / 30 kWEqual usable capacity
TopologyOnline double-conversionOnline double-conversionEquivalent protection
Battery technologyLithium iron phosphate (LiFePO₄)VRLA (lead-acid)Li90 — extended lifecycle
Battery design lifeUp to 15 yearsTypically 3–5 yearsLi90 — fewer replacements
Internal runtime15 minutes10 minutesLi90 — greater internal runtime
Runtime expansionIntegrated lithium runtimeExternal battery cabinets typically requiredLi90 — simplified planning
Online efficiency94.5%93.4%Li90 — higher efficiency
Cabinet width12.6 in23.6 inLi90 — higher power density
Installed weight483 lb>1,200 lb (by configuration)Li90 — reduced installation burden
Installation modelRetrofit modernizationConventional replacementLi90 — simplified upgrade

Specifications based on publicly available manufacturer data; verify against current Vertiv documentation. Both are online double-conversion; the Li90 uses LiFePO₄.

Where each fits

Choosing between them

Many facilities still run VRLA-based three-phase UPS that need periodic battery replacement, environmental conditioning, and ongoing maintenance. The Li90 is evaluated as a modernization path — integrated lithium for longer service life, a compact cabinet for better electrical-room utilization, and reduced maintenance intervention versus a conventional VRLA platform like the EXS-V.

Choose the Li90 if you need

  • Integrated lithium with long service life and low maintenance
  • A compact footprint and higher power density
  • Internal runtime without external battery cabinets
  • A retrofit-oriented modernization path
  • Reduced installation burden (much lighter system)

Choose the Vertiv EXS-V if you need

  • Standardization on Vertiv / VRLA battery infrastructure
  • A conventional capacity-replacement project
  • Alignment with an existing Vertiv installed-base ecosystem

Plan your three-phase UPS modernization

Xtreme Power supports facility engineers and planners with lithium UPS modernization strategy, lifecycle cost modeling, and retrofit planning.