20–30 kVA · 208/120 V · Three-Phase Facility UPS Comparison

Li90 vs Vertiv EXS-V

Engineers modernizing facility three-phase UPS in the 20–30 kVA range frequently compare the Xtreme Power Li90 with the Vertiv EXS-V. Both provide true online double-conversion protection with internal batteries for 208/120 V applications; the Li90 is a lithium-integrated modernization platform with unity power factor and reduced electrical-room burden, where the EXS-V is a conventional VRLA platform.

Xtreme Power
Li90 Series
vs
Vertiv
EXS-V Series
Key differentiators at a glance

Why engineers evaluate the Li90

  • Integrated, modular internal lithium (LiFePO₄) battery architecture
  • Extended battery lifecycle vs VRLA — up to 15 years / 3,000–5,000 cycles
  • Unity (1.0) output power factor — more usable real power (kW)
  • Operating efficiency up to 94.5%
  • Reduced lifecycle battery replacement planning
  • Compact cabinet — improved electrical-room density
  • Simplified retrofit / modernization strategy
Side-by-side

Facility UPS comparison · 20–30 kVA

FeatureXtreme Power Li90 SeriesVertiv EXS-V SeriesAdvantage / consideration
Capacity range20–30 kVA15–40 kVAComparable within overlapping range
Output voltage208/120 V three-phase208/120 V three-phaseAligned North American compatibility
Battery chemistryLithium iron phosphateVRLALi90 — extended lifecycle
Battery architectureModular internal lithium modulesInternal VRLA modulesLi90 — lifecycle & serviceability
UPS topologyOnline double-conversionOnline double-conversionEquivalent conditioned power
Output power factorUnity (1.0)0.9Li90 — more usable real power
Operating efficiencyUp to 94.5%93.4%Li90 — lower energy losses
Lifecycle maintenanceReduced battery replacementPeriodic VRLA replacementLi90 — predictable lifecycle cost
Runtime strategyModular internal lithium scalabilityInternal VRLA + expansionComparable, differing lifecycle assumptions
Maintenance bypassIntegratedIntegratedEquivalent serviceability
MonitoringEnterprise SNMP / networkEnterprise SNMP / networkComparable integration
Infrastructure modernizationRetrofit-oriented platformConventional replacement modelLi90 — modernization advantage

Specifications based on publicly available manufacturer documentation; verify against current Vertiv data. Both platforms are online double-conversion; the Li90 uses LiFePO₄.

Where each fits

Choosing between them

Facility three-phase UPS in the 10–30 kVA range protects healthcare imaging infrastructure, industrial automation, commercial-building modernization, telecom power rooms, and distributed mission-critical loads. The Li90 brings integrated lithium to this class — cutting battery-replacement planning and electrical-room burden versus a VRLA platform, while unity power factor delivers more usable kW from the same kVA.

Choose the Li90 if you need

  • Integrated internal lithium — no external battery cabinets
  • Reduced battery maintenance and predictable lifecycle cost
  • Unity (1.0) power factor for more usable kW
  • A compact footprint for limited electrical-room space
  • A retrofit-oriented path to modernize legacy VRLA infrastructure

The Vertiv EXS-V may fit if you need

  • Standardization on Vertiv / existing service
  • A conventional VRLA deployment model in place
  • Capacities beyond 30 kVA (EXS-V spans 15–40 kVA)

Plan your lithium UPS modernization

Xtreme Power supports facility engineers and infrastructure planners with lithium UPS modernization strategy, lifecycle cost modeling, and deployment architecture guidance.