Identify the correct Xtreme Power modular UPS replacement for your Eaton BladeUPS system by catalog number, voltage, and capacity.

The Eaton BladeUPS platform has been discontinued, and many installed systems are approaching end-of-service or support limitations. This cross reference allows engineers, facility managers, and contractors to match existing BladeUPS configurations to modern Xtreme Power M90C, M90U, or M90Ci modular UPS replacements.

Find Your Exact BladeUPS Replacement

Search your Eaton BladeUPS catalog number below to identify the recommended Xtreme Power replacement platform and expansion options.

View full BladeUPS cross reference
https://xpcc.com/eaton-bladeups-cross-reference/

Download BladeUPS Cross Reference (PDF)
https://xpcc.com/wp-content/uploads/BladeUPS-XPC-Cross-Reference.pdf

Request BladeUPS replacement quote
sales@xpcc.com | 1-800-582-4524

Most Common Eaton BladeUPS Replacements

Thousands of BladeUPS systems were deployed across 208 V North American IT environments and 400 V global telecom and data center infrastructure. The capacities below represent the most frequently installed BladeUPS configurations and their recommended Xtreme Power modular UPS replacements.

BladeUPS Capacity Typical Voltage Recommended Xtreme Power Replacement
5 kW BladeUPS 208 V 3-phase M90C-2S5K
8 kW BladeUPS 208 V 3-phase M90C-2S8K
12 kW BladeUPS 208 V 3-phase M90C-6S16k2 or M90U-15k
12 kW BladeUPS 400 V 3-phase M90Ci-2S10k
24 kW BladeUPS 208 V 3-phase M90C-6S24k3 or M90U-30k
36 kW BladeUPS 208 V 3-phase M90U-40k
48 kW BladeUPS 208 V 3-phase M90U-60k
60 kW BladeUPS / N+1 208 V 3-phase M90U-60k or M90U-80 N+1

Xtreme Power modular UPS platforms provide higher efficiency, modern serviceability, and long-term lifecycle support for organizations replacing discontinued BladeUPS infrastructure.

208 V BladeUPS Catalog Number Cross Reference

North American BladeUPS deployments were typically installed in IDF/MDF closets, telecom racks, enterprise IT rooms, and distributed edge sites.

Typical Xtreme Power replacements:
M90C modular UPS (5–24 kW)
M90U modular UPS (15–60 kW)

Eaton Cat. Number Capacity Voltage Recommended Xtreme Power Base Model Alternate / Expansion
ZC121TB00100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC121P068100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC121P064100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC121P062100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC121P060100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC121P060000000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212608100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212600100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212248100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212208100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212200100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212048100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC1212008100000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZC0811148100000 8 kW 208 V 3Φ M90C-2S8K E91-10k
ZC0811108100000 8 kW 208 V 3Φ M90C-2S8K E91-10k
ZC0811104100000 8 kW 208 V 3Φ M90C-2S8K E91-10k
ZC0811100100000 8 kW 208 V 3Φ M90C-2S8K E91-10k
ZC0517708110040 5 kW 208 V 3Φ M90C-2S5K E91-10k
ZC0517708110000 5 kW 208 V 3Φ M90C-2S5K E91-10k
ZC0517708100000 5 kW 208 V 3Φ M90C-2S5K E91-10k
ZC0517700110000 5 kW 208 V 3Φ M90C-2S5K E91-10k
ZC0517700100000 5 kW 208 V 3Φ M90C-2S5K E91-10k

400 V BladeUPS Catalog Number Cross Reference

International BladeUPS systems were commonly installed in global telecom infrastructure, containerized data centers, and enterprise facilities.

Typical Xtreme Power replacement:
M90Ci modular UPS (10–60 kW)

Eaton Cat. Number Capacity Voltage Recommended Xtreme Power Base Model Alternate / Expansion
ZC122P068120050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122P068100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122P060120050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122P060120000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122P060100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122F902120040 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122A948120040 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC122A902120040 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1228808190050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1228808120050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224408120050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224408100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224402120040 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224401100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224400190050 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224400100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224008100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2
ZC1224000100000 12 kW 400 V 3Φ M90Ci-2S10k M90Ci-6S20K2

Large BladeUPS Systems (24–60 kW)

Large BladeUPS frames were typically deployed in data center rows, electrical rooms, and high-availability enterprise infrastructure.

Eaton Cat. Number Capacity Voltage Recommended Xtreme Power Base Model Alternate / Expansion
ZP2631500XXX100 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2631500XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2631000XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP262150XXXX100 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP262150XXXX000 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP262100XXXX100 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP262100XXXX000 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP26115XXXXX000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP26110XXXXX000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP2531500XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2531000XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP252150XXXX100 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP252150XXXX000 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP252100XXXX100 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP252100XXXX000 24 kW 208 V 3Φ M90C-6S24k3 M90U-30k06BM
ZP25115XXXXX100 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP25115XXXXX000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP25110XXXXX100 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP25110XXXXX000 12 kW 208 V 3Φ M90C-6S16k2 M90U-15k04BM
ZP24415000XX100 48 kW 208 V 3Φ M90U-60k12BM M90U80-60K12B
ZP24415000XX000 48 kW 208 V 3Φ M90U-60k12BM M90U80-60K12B
ZP24410000XX100 48 kW 208 V 3Φ M90U-60k12BM M90U80-60K12B
ZP24410000XX000 48 kW 208 V 3Φ M90U-60k12BM M90U80-60K12B
ZP2431540XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2431500XXX100 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2431500XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2431000XXX100 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP2431000XXX000 36 kW 208 V 3Φ M90U-40k08BM M90U80-40K08B
ZP242154XXXX000 24 kW 208 V 3Φ M90U-30k06BM M90U80-30K06B
ZP242150XXXX100 24 kW 208 V 3Φ M90U-30k06BM M90U80-30K06B
ZP242150XXXX000 24 kW 208 V 3Φ M90U-30k06BM M90U80-30K06B
ZP242100XXXX100 24 kW 208 V 3Φ M90U-30k06BM M90U80-30K06B
ZP242100XXXX000 24 kW 208 V 3Φ M90U-30k06BM M90U80-30K06B
ZP24115XXXXX100 12 kW 208 V 3Φ M90U-15k04BM M90U80-15K04B
ZP24115XXXXX000 12 kW 208 V 3Φ M90U-15k04BM M90U80-15K04B
ZP24110XXXXX100 12 kW 208 V 3Φ M90U-15k04BM M90U80-15K04B

Configuration Note

Add optional line cord, receptacle panel(s), connectivity options, and runtime modules as required.
Consult Xtreme Power Sales for final replacement configuration: sales@xpcc.com

Related BladeUPS Replacement Platforms

Explore detailed specifications and configurations for the Xtreme Power modular UPS platforms commonly used to replace Eaton BladeUPS systems.

M90C-2S Modular UPS (5–8 kW)
https://xpcc.com/products/m90c-2s/

M90C-6S Modular UPS (5–24 kW)
https://xpcc.com/products/m90c-6s/

M90Ci-2S Modular UPS (10 kW)
https://xpcc.com/products/m90ci-2s/

M90Ci-6S Modular UPS (10–60 kW)
https://xpcc.com/products/m90ci-6s/

M90U Modular UPS (15–60 kW)
https://xpcc.com/products/m90u/

M90U-80 Modular UPS (up to 80 kW / N+1)
https://xpcc.com/products/m90u-80/

E91 Three-Phase UPS (10–20 kW)
https://xpcc.com/products/e91_10-20k/

Need Help Selecting the Correct BladeUPS Replacement

Contact Xtreme Power engineering support for configuration verification or migration planning.

sales@xpcc.com
1-800-582-4524