Identify the correct Xtreme Power modular UPS replacement for your Eaton BladeUPS system by catalog number, voltage, and capacity.
The Eaton BladeUPS platform has been discontinued, and many installed systems are approaching end-of-service or support limitations. This cross reference allows engineers, facility managers, and contractors to match existing BladeUPS configurations to modern Xtreme Power M90C, M90U, or M90Ci modular UPS replacements.

Find Your Exact BladeUPS Replacement
Search your Eaton BladeUPS catalog number below to identify the recommended Xtreme Power replacement platform and expansion options.
View full BladeUPS cross reference
https://xpcc.com/eaton-bladeups-cross-reference/
Download BladeUPS Cross Reference (PDF)
https://xpcc.com/wp-content/uploads/BladeUPS-XPC-Cross-Reference.pdf
Request BladeUPS replacement quote
sales@xpcc.com | 1-800-582-4524
Most Common Eaton BladeUPS Replacements
Thousands of BladeUPS systems were deployed across 208 V North American IT environments and 400 V global telecom and data center infrastructure. The capacities below represent the most frequently installed BladeUPS configurations and their recommended Xtreme Power modular UPS replacements.
| BladeUPS Capacity | Typical Voltage | Recommended Xtreme Power Replacement |
| 5 kW BladeUPS | 208 V 3-phase | M90C-2S5K |
| 8 kW BladeUPS | 208 V 3-phase | M90C-2S8K |
| 12 kW BladeUPS | 208 V 3-phase | M90C-6S16k2 or M90U-15k |
| 12 kW BladeUPS | 400 V 3-phase | M90Ci-2S10k |
| 24 kW BladeUPS | 208 V 3-phase | M90C-6S24k3 or M90U-30k |
| 36 kW BladeUPS | 208 V 3-phase | M90U-40k |
| 48 kW BladeUPS | 208 V 3-phase | M90U-60k |
| 60 kW BladeUPS / N+1 | 208 V 3-phase | M90U-60k or M90U-80 N+1 |
Xtreme Power modular UPS platforms provide higher efficiency, modern serviceability, and long-term lifecycle support for organizations replacing discontinued BladeUPS infrastructure.
208 V BladeUPS Catalog Number Cross Reference
North American BladeUPS deployments were typically installed in IDF/MDF closets, telecom racks, enterprise IT rooms, and distributed edge sites.
Typical Xtreme Power replacements:
M90C modular UPS (5–24 kW)
M90U modular UPS (15–60 kW)
| Eaton Cat. Number | Capacity | Voltage | Recommended Xtreme Power Base Model | Alternate / Expansion |
| ZC121TB00100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC121P068100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC121P064100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC121P062100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC121P060100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC121P060000000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212608100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212600100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212248100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212208100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212200100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212048100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC1212008100000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZC0811148100000 | 8 kW | 208 V 3Φ | M90C-2S8K | E91-10k |
| ZC0811108100000 | 8 kW | 208 V 3Φ | M90C-2S8K | E91-10k |
| ZC0811104100000 | 8 kW | 208 V 3Φ | M90C-2S8K | E91-10k |
| ZC0811100100000 | 8 kW | 208 V 3Φ | M90C-2S8K | E91-10k |
| ZC0517708110040 | 5 kW | 208 V 3Φ | M90C-2S5K | E91-10k |
| ZC0517708110000 | 5 kW | 208 V 3Φ | M90C-2S5K | E91-10k |
| ZC0517708100000 | 5 kW | 208 V 3Φ | M90C-2S5K | E91-10k |
| ZC0517700110000 | 5 kW | 208 V 3Φ | M90C-2S5K | E91-10k |
| ZC0517700100000 | 5 kW | 208 V 3Φ | M90C-2S5K | E91-10k |
400 V BladeUPS Catalog Number Cross Reference
International BladeUPS systems were commonly installed in global telecom infrastructure, containerized data centers, and enterprise facilities.
Typical Xtreme Power replacement:
M90Ci modular UPS (10–60 kW)
| Eaton Cat. Number | Capacity | Voltage | Recommended Xtreme Power Base Model | Alternate / Expansion |
| ZC122P068120050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122P068100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122P060120050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122P060120000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122P060100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122F902120040 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122A948120040 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC122A902120040 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1228808190050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1228808120050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224408120050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224408100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224402120040 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224401100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224400190050 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224400100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224008100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
| ZC1224000100000 | 12 kW | 400 V 3Φ | M90Ci-2S10k | M90Ci-6S20K2 |
Large BladeUPS Systems (24–60 kW)
Large BladeUPS frames were typically deployed in data center rows, electrical rooms, and high-availability enterprise infrastructure.
| Eaton Cat. Number | Capacity | Voltage | Recommended Xtreme Power Base Model | Alternate / Expansion |
| ZP2631500XXX100 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2631500XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2631000XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP262150XXXX100 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP262150XXXX000 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP262100XXXX100 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP262100XXXX000 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP26115XXXXX000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP26110XXXXX000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP2531500XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2531000XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP252150XXXX100 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP252150XXXX000 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP252100XXXX100 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP252100XXXX000 | 24 kW | 208 V 3Φ | M90C-6S24k3 | M90U-30k06BM |
| ZP25115XXXXX100 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP25115XXXXX000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP25110XXXXX100 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP25110XXXXX000 | 12 kW | 208 V 3Φ | M90C-6S16k2 | M90U-15k04BM |
| ZP24415000XX100 | 48 kW | 208 V 3Φ | M90U-60k12BM | M90U80-60K12B |
| ZP24415000XX000 | 48 kW | 208 V 3Φ | M90U-60k12BM | M90U80-60K12B |
| ZP24410000XX100 | 48 kW | 208 V 3Φ | M90U-60k12BM | M90U80-60K12B |
| ZP24410000XX000 | 48 kW | 208 V 3Φ | M90U-60k12BM | M90U80-60K12B |
| ZP2431540XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2431500XXX100 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2431500XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2431000XXX100 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP2431000XXX000 | 36 kW | 208 V 3Φ | M90U-40k08BM | M90U80-40K08B |
| ZP242154XXXX000 | 24 kW | 208 V 3Φ | M90U-30k06BM | M90U80-30K06B |
| ZP242150XXXX100 | 24 kW | 208 V 3Φ | M90U-30k06BM | M90U80-30K06B |
| ZP242150XXXX000 | 24 kW | 208 V 3Φ | M90U-30k06BM | M90U80-30K06B |
| ZP242100XXXX100 | 24 kW | 208 V 3Φ | M90U-30k06BM | M90U80-30K06B |
| ZP242100XXXX000 | 24 kW | 208 V 3Φ | M90U-30k06BM | M90U80-30K06B |
| ZP24115XXXXX100 | 12 kW | 208 V 3Φ | M90U-15k04BM | M90U80-15K04B |
| ZP24115XXXXX000 | 12 kW | 208 V 3Φ | M90U-15k04BM | M90U80-15K04B |
| ZP24110XXXXX100 | 12 kW | 208 V 3Φ | M90U-15k04BM | M90U80-15K04B |
Configuration Note
Add optional line cord, receptacle panel(s), connectivity options, and runtime modules as required.
Consult Xtreme Power Sales for final replacement configuration: sales@xpcc.com
Related BladeUPS Replacement Platforms
Explore detailed specifications and configurations for the Xtreme Power modular UPS platforms commonly used to replace Eaton BladeUPS systems.
M90C-2S Modular UPS (5–8 kW)
https://xpcc.com/products/m90c-2s/
M90C-6S Modular UPS (5–24 kW)
https://xpcc.com/products/m90c-6s/
M90Ci-2S Modular UPS (10 kW)
https://xpcc.com/products/m90ci-2s/
M90Ci-6S Modular UPS (10–60 kW)
https://xpcc.com/products/m90ci-6s/
M90U Modular UPS (15–60 kW)
https://xpcc.com/products/m90u/
M90U-80 Modular UPS (up to 80 kW / N+1)
https://xpcc.com/products/m90u-80/
E91 Three-Phase UPS (10–20 kW)
https://xpcc.com/products/e91_10-20k/
Need Help Selecting the Correct BladeUPS Replacement
Contact Xtreme Power engineering support for configuration verification or migration planning.
sales@xpcc.com
1-800-582-4524