5 kVA · Isolation Online UPS · Galvanic Isolation · PowerVAR Comparison

TX91-5kVA vs PowerVAR

The Xtreme Power TX91-5kVA and the PowerVAR isolation UPS are true online double-conversion systems with integrated isolation transformers, for electrically noisy industrial, laboratory, and infrastructure environments. Both deliver galvanic isolation and strong surge immunity. The TX91-5kVA differentiates on longer internal runtime (with an XR variant), plug-and-play configuration flexibility, and built-in TAA compliance.

Xtreme Power
TX91-5kVA
vs
PowerVAR
(model TBD)
Where the TX91-5kVA leads

Where the TX91-5kVA leads

  • Longer internal runtime — about 10 minutes (or ~15 with the XR model) versus about 8 minutes.
  • An XR extended-runtime variant for longer backup without external batteries.
  • More flexible, configurable input/output versus a hardwired-first design.
  • Built-in TAA compliance for federal and regulated procurement.
Side-by-side

5000 VA isolation UPS, side by side

SpecificationXtreme Power TX91-5kVAPowerVAR (model TBD)Advantage
UPS capacity5000 VA / 5000 W (unity PF)5200 VA / 5200 W (unity PF)PowerVAR higher nominal VA
TopologyOnline double-conversion with isolation transformerOnline double-conversion with isolation transformerBoth galvanic isolation
ANSI/IEEE C62.41YesYesEquivalent surge
Output voltage options120 / 208 / 220 / 230 / 240 VAC120 / 208 / 220 / 230 / 240 VACAligned
Internal runtime (full load)~10 min (or ~15 min XR)~8 minLonger runtime
Optional external battery packsYesYesEquivalent scalability
Input / output architectureOptional / configurableHardwired standard; plugs optionalGreater flexibility
Dimensions (W × H × D)9.9 × 32.4 × 23.3 in9.8 × 32.5 × 24.7 inSimilar; TX91 slightly shallower
Warranty3 yr electronics / 3 yr battery3 yr electronics / 3 yr batteryEquivalent
Compliance / listingsUL1778, cUL, FCC-A, RoHS, TAAUL1778, CSA, EN 62040-2, RoHSComparable
TAA complianceYesNoFederal procurement

Both are true online double-conversion isolation UPS with galvanic isolation, equivalent surge performance, the same multi-voltage output, and matching 3-year warranties. The TX91 leads on internal runtime and input/output flexibility and adds TAA; PowerVAR carries a slightly higher nominal VA rating and a hardwired-first design. Confirm current PowerVAR specifications against vendor documentation.

Where each fits

Choosing between them

Both deliver galvanic isolation and online double-conversion protection at ~5 kVA. Choose the TX91-5kVA for longer internal runtime, an XR option, flexible input/output, and TAA; PowerVAR fits where a hardwired-first design, a slightly higher nominal VA, or an existing PowerVAR standard governs.

Choose the TX91-5kVA if you need

  • Built-in TAA compliance for federal, education, and public-sector procurement
  • Longer internal runtime without external batteries
  • XR extended-runtime capability
  • A narrower, shallower isolation UPS for space-limited installations
  • Simplified procurement for regulated environments

The (model TBD) may fit if you need

  • A slightly higher nominal VA / kW rating
  • A hardwired-first industrial design
  • Existing PowerVAR-standardized environments
  • Deployment in non-TAA-regulated projects

Sizing an isolation UPS for a regulated or industrial deployment?

Xtreme Power supports TX91 isolation UPS sizing, runtime configuration (XR internal and external BP960 cabinets), grounding and power-quality strategy, and TAA-compliant procurement for industrial automation, medical imaging, and laboratory infrastructure.