• SNMP-1PIN Internal SNMP Card
  • XPRT-RELAY Internal Relay Card

T91 Online UPS – Long-Runtime Tower UPS (1000–3000 VA, 120V)

1000–3000 VA | 120V | Online Double Conversion

Long-runtime tower UPS engineered for commercial, retail, healthcare, and distributed infrastructure requiring multi-hour backup power and continuous conditioned output.

Category:

The T91 Series is an online double-conversion UPS designed for applications where extended runtime is required beyond the limits of compact rack UPS systems.

With external battery expansion and a high-capacity programmable charger, T91 supports runtime from short ride-through to multi-hour continuity while maintaining zero transfer time and stable output for sensitive loads.

Key Specifications

  • 1000 / 1500 / 2000 / 3000 VA
  • 120V single phase
  • Online double-conversion topology
  • Unity output power factor (1.0)
  • Tower form factor
  • External battery expansion
  • Programmable charger (2–8 A)
  • Optional SNMP / network monitoring
  • TAA compliant

Datasheet:
https://xpcc.com/wp-content/uploads/T91-flyer.pdf

Long-Runtime Power Architecture

T91 is designed for environments where outages extend beyond typical UPS runtime expectations.

Unlike rack UPS systems optimized for short-duration protection, T91 uses external battery systems and programmable charging to support multi-hour runtime requirements. This allows infrastructure to remain operational during extended outages or until backup generation is available.

Online double-conversion topology ensures continuous conditioned power, isolating connected equipment from voltage fluctuations and electrical disturbances.

Where T91 Fits in Power Architecture

T91 operates as the long-runtime tower UPS platform within distributed infrastructure.

It is typically deployed:

  • in floor-mounted or equipment-adjacent installations
  • in retail, hospitality, and medical environments
  • where runtime requirements exceed rack UPS capabilities

Within the Xtreme Power architecture:

  • P80 → efficient rack UPS
  • P91 → rack UPS with scalable runtime
  • T91 → long-runtime tower UPS (this platform)
  • J90 → high-density lithium rack UPS

T91 vs Rack UPS Platforms

Rack UPS systems are typically optimized for density and short-duration runtime.

T91 is designed for applications where runtime is the primary requirement. Its tower form factor supports larger battery systems and higher charging capacity, enabling significantly longer backup durations.

For rack-based runtime solutions, see:
https://xpcc.com/products/p91_1-3/

Replace APC / Eaton Long-Runtime UPS

T91 is commonly deployed as a replacement for tower-based and extended runtime UPS platforms including:

  • APC Smart-UPS SRT tower configurations with external battery packs
  • Eaton 9PX / 9SX extended runtime systems
  • Vertiv Liebert GXT tower deployments

It provides a simplified long-runtime architecture with programmable charging and scalable battery expansion for consistent deployment across multiple sites.

Explore comparisons:
https://xpcc.com/t91-online-ups-competitive-comparisons/

Runtime Architecture and Deployment Flexibility

T91 is designed to support a wide range of runtime strategies.

External battery expansion enables runtime from minutes to multiple hours, depending on load and battery configuration. The programmable charger supports larger battery banks and reduces recharge time after extended outages.

Typical use cases include refrigeration protection, retail continuity, network uptime, and healthcare-related runtime requirements.

UPS sizing tool:
https://xpcc.com/selector

Typical Applications

T91 is deployed across commercial and regulated environments including retail and restaurant operations, hospitality systems, medical refrigeration, network infrastructure, and government installations.

It is particularly well suited for distributed sites where extended runtime is required to maintain operations during prolonged outages.

Capacity Guidance

Capacity selection is based on load and runtime objectives:

  • 1000 VA → small systems and POS equipment
  • 1500–2000 VA → retail, network, and control systems
  • 3000 VA → higher-load commercial infrastructure

Runtime is defined by battery configuration and continuity requirements, with extended runtime capability up to multi-hour operation.

Higher Voltage Option

For installations requiring 208–240V output, see the higher-voltage version of this platform:

T91i Online UPS
https://xpcc.com/products/t91i-online-ups/

Xtreme Power UPS Platform Context

T91 serves as the long-runtime platform within the broader UPS architecture:

  • P80 → line-interactive rack UPS
  • P91 → rack UPS with scalable runtime
  • T91 → extended runtime tower UPS
  • J90 → lithium rack UPS
  • Li90 → facility-level lithium UPS

Technical Summary

Topology: Online double conversion
Capacity: 1000–3000 VA
Voltage: 120V
Battery: External expansion
Form Factor: Tower
Runtime: Scalable (up to multi-hour)
Monitoring: Optional SNMP / web
Compliance: UL, cUL, RoHS, TAA

Plan With Confidence

Xtreme Power Conversion supports engineers and infrastructure planners in designing long-runtime UPS systems for commercial continuity, extended outage protection, and distributed deployment strategies.

Phone: (800) 582-4524
Email: sales@xpcc.com

MODEL NUMBER T91-700 T91-1000 T91-1500 T91-2000 T91-2000V2 T91-3000
CAPACITY Power rating 700VA (700W) 1000VA (1000W) 1500VA (1450W) 2000VA (1930W) 2000VA (1930W) 3000VA (2880W)
INPUT Voltage     120VAC nominal (55-150VAC)*
Frequency 50/60Hz auto-sensing
Power factor >0.99 at full load
OUTPUT Voltage 120VAC nominal (100/110/115/127 selectable)**
Waveform Pure sine wave, zero transfer time
Frequency 50/60Hz auto-sensing ≤ 1%
Efficiency  Up to 98% ECO Mode and 92% online mode
Overload capacity > 110% & ≤ 130% for 5 min; > 130% & ≤140% for 30 sec; >140% for 1.5 sec
BATTERY Battery type (2) 12V 9AH (3) 12V 9AH (3) 12V 9AH (6) 12V 9AH (6) 12V 9AH
Recharge 3 hours to 95% for internal battery with 2A charge current
Battery charger 2A (default) to 8A, programmable from LCD display
PHYSICAL UPS dimensions 5.6″ x 15.6″ x 8.6″ (W x D x H) 7.4″ x 16.5″ x 12.5″ (W x D x H)
UPS weight 26 lbs 30 Ibs 34.3 lbs 63 lbs 66 lbs
Line cord 6 ft, 5–15P 6 ft, L5–20P 6 ft, 5-20P 6 ft, L5–30P
Receptacles (6) 5–15R (1) L5-20R+(8) 5-20R (1) L5-30R+(8) 5-20R
OPTIONAL Model number N/A T91-BP36A T91-BP72A
BATTERY PACKS Dimensions N/A 5.6″ W x 15.6″ D x 8.6″ H 7.4″ W x 16.5″ D x 12.5″ H
Weight N/A 44 Ibs 82 Ibs
ENVIRONMENT Temperature 32–104°F (0–40°C)
Audible noise < 50 dBA
Altitude 11,500 ft above sea level
APPROVALS UL1778 (cTUVus), FCC B, RoHS, TAA
WARRANTY 3 years electronics, 3 years battery warranty (USA and Canada)
COMMUNICATIONS INTERFACE RS-232, USB, EPO, intelligent slot for optional cards (Web/SNMP, Relay/dry contact, Modbus)
INCLUDED IN BOX ViewPower monitoring software CD, USB cable, user manual
AVAILABLE OPTIONS Extended warranty, bypass distribution (XBDM), power distribution (XPDU)
  1. Mounting Kits

    [table colwidth=”75″]
    ,Model,Description,Unit Weight, Unit Dimensions
    ,T90-WMB,”Wall Mount Bracket for use with T91-700, T91-1000, T91-1500, T90-2000, T91i-2000; Rated for 40 lbs”,5 lbs,4.0”-8.0” x 7.0” x 8.0”
    [/table]

  2. Connectivity

    [table colwidth=”75″]
    ,Model,Description,Unit Weight, Unit Dimensions
    ,SNMP-2PV3,”Two Port Internal SNMP Card”, 1 lb,7.25″ x 6″ x 2.5″

     

    ,SNMP-EMPV2,”Environmental Monitoring Sensor”, 1 lb,7.25″ x 6″ x 2.5″

     

    [/table]

  3. Bypass Distribution Modules

    [table colwidth=”75″]
    ,Model,Description,Utility Input, Output Connections, UPS Connections, Unit Weight, Unit Dimensions
    ,XBDM1020HV1,Bypass 16A capacity for use with T90i-1500 (includes IEC C20 C19 cord kit),”IEC C20 inlet”,”(2) IEC C19 + (4) IEC C13 front, (4) IEC C13 back”,IEC C20,3.5 lbs,19.3″ x 3.5″ x 1.75″
    [/table]

  4. Power Distribution Units & Transformers

    [table colwidth=”75″]
    ,Model,Description,Input Power Cord, Outlets, Unit Weight, Unit Dimensions
    ,XPDU-IEC,230V Basic Power Distribution Unit for use with T90i-1500,IEC C20 inlet,(10) IEC C13 + (2) IEC C19,2.6 lbs,19.0″ x 3.5″ x 1.75″
    ,XPD-AT15A,1500W Transformer PDU with Meter 208V to 120V for use with T90i-1500,”Detachable IEC C14, 3ft”,(16) 5–15R,19.7 lbs,19.0” x 10.5” x 3.5”
    ,XAT-400,400VA Step Down Transformer 208V to 120V for use with T90i-1500,”208V IEC C14, 2ft”,”120V 5–15R, 2ft”,8.0 lbs,7.0” x 6.8” x 5.9”
    [/table]