3000 VA / 2880 W · 120VAC · Online Double-Conversion Rack UPS Comparison

P91-3000 vs APC Smart-UPS SRT3000XLA

The P91-3000 and APC Smart-UPS SRT3000XLA are both true online double-conversion UPS delivering continuous sine-wave output for mission-critical IT, network, and edge infrastructure. The P91-3000 differentiates with higher usable watts, a shallower rack footprint, more built-in outlets, longer battery design life, and full TAA compliance.

Xtreme Power
P91-3000
vs
APC
Smart-UPS SRT3000XLA
Where the P91-3000 leads

What the P91-3000 brings

  • Higher usable watts (2880 W vs 2700 W)
  • Shallower rack depth (24.8 in vs 27.0 in)
  • Two more built-in outlets (8 vs 6)
  • Longer battery design life (3–5 yr vs 2–3 yr) and warranty
  • TAA compliance for federal procurement
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-3000APC Smart-UPS SRT3000XLAAdvantage
Capacity3000 VA / 2880 W3000 VA / 2700 WP91 – higher usable watts
TopologyOnline double-conversionOnline double-conversionEquivalent protection
Form factorRack / tower convertible (2U)Rack / tower convertible (2U)Equivalent
UPS depth24.8 in27.0 inP91 – shallower
Connections5-30P in · (8) NEMA 5-15/20R5-30P in · (6) NEMA 5-20RP91 – two more outlets
Battery design life3–5 years2–3 yearsP91 – fewer replacements
Warranty3 yr electronics / 3 yr battery3 yr electronics / 2 yr batteryP91 – longer battery coverage
TAA complianceYes (made in Taiwan)NoP91 – federal procurement

Specifications from Xtreme Power’s supplied P91-3000 vs APC SRT3000XLA comparison; confirm against current vendor documentation. Both are online double-conversion VRLA platforms.

Where each fits

Choosing between them

Both deliver equivalent online protection in 2U convertible form factors. The P91-3000 leads on usable watts, depth, outlet count, battery life, and TAA; the APC suits APC-standardized, full-depth environments.

Choose the P91-3000 if you need

  • Edge, IDF, and MDF deployments where depth and clearance matter
  • Federally funded and TAA-restricted procurement
  • More built-in outlets without external PDUs
  • Longer battery life and lower total cost of ownership

The Smart-UPS SRT3000XLA may fit if you need

  • Existing APC-standardized environments
  • Locking-only receptacle strategies
  • Climate-controlled, full-depth racks where TAA isn’t required

Specifying a scalable-runtime online UPS?