2000 VA · 120 VAC · Pure Sine Line-Interactive Rack UPS · APC Smart-UPS X Comparison

P80-2000 vs APC Smart-UPS X SMX2000LV

The Xtreme Power P80-2000 and APC Smart-UPS X SMX2000LV are 120 V pure sine wave line-interactive rack UPS delivering the same 1800 W. The decisive difference is rack architecture: the P80-2000 fits that power into 2U at 47 lb, where the SMX2000LV is a 4U unit at 85 lb.

Xtreme Power
P80-2000
vs
APC
Smart-UPS X SMX2000LV
Where the P80-2000 leads

What the P80-2000 brings

  • Same 1800 W in 2U vs APC 4U — half the rack height.
  • 47.4 lb vs 85.2 lb — roughly 38 lb lighter.
  • Optional XBDM maintenance bypass (APC: none).
  • Tower, wall, 2-post and 4-post mounting (APC: rack / tower only).
  • Up to 99% ECO-mode efficiency and a 3-year battery warranty.
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P80-2000APC Smart-UPS X SMX2000LVAdvantage
Rated capacity2000 VA / 1800 W1920 VA / 1800 WEqual 1800 W; P80 higher nominal VA
UPS topologyLine-interactive, AVR, sine waveLine-interactive, AVR, sine waveEquivalent protection
Form factor2U rack / tower / wall4U rack / towerP80 2U vs 4U; adds wall & 2-post
Dimensions (W×D×H)17.2 × 19.9 × 3.5 in (2U)17.0 × 19.0 × 7.0 in (4U)P80 denser in-rack
Weight47.4 lb85.2 lbP80 approx 38 lb lighter
Input cord6 ft, NEMA 5-20PNEMA 5-20PEquivalent (both 20 A)
Output receptacles(8) NEMA 5-15/20R(6) 5-15R + (3) 5-20R + (1) L5-20RAPC more outlets (10 vs 8)
Extended runtimeYes (P90-BP48 packs)Yes (external packs)Equivalent
CommunicationsUSB, RS-232, optional Web/SNMPUSB, RS-232, SmartSlot (optional NMC)Both local; no cloud dependency
Maintenance bypassOptional XBDM moduleNoneP80 serviceable without downtime
EfficiencyUp to 99% ECO modeGreen modeP80 higher peak efficiency
TAA complianceYesYesBoth eligible
Warranty3-yr UPS & battery3-yr UPS / 2-yr batteryP80 longer battery coverage

Both are 2000-class line-interactive AVR sine wave UPS delivering 1800 W. Real output watts are identical; the P80 rates higher nominal VA. The P80-2000 leads decisively on rack density and weight (2U at 47 lb vs 4U at 85 lb), plus maintenance bypass, mounting flexibility, and battery warranty. Confirm APC specifications against current APC documentation.

Where each fits

Choosing between them

Both are 2000-class line-interactive AVR sine wave UPS delivering 1800 W. The P80-2000 leads decisively on rack density and weight — the same power in 2U at 47 lb versus 4U at 85 lb — plus maintenance bypass, mounting flexibility, and battery warranty. The SMX2000LV fits APC-standardized sites wanting more onboard outlets where 4U height is acceptable.

Choose the P80-2000 if you need

  • Rack-density-constrained deployments (2U vs 4U)
  • Sites that handle and service their own units (weight)
  • Maintenance bypass for in-place service
  • Wall / 2-post branch and edge installations

The Smart-UPS X SMX2000LV may fit if you need

  • Standardization on the APC Smart-UPS ecosystem
  • Maximum onboard outlet count and an L5-20R receptacle
  • Deployments where 4U height is not a constraint

Specify the right line-interactive rack UPS

Talk to an Xtreme Power specialist about UPS selection, runtime sizing with external battery packs, maintenance-bypass options, and rack / wall / 2-post deployment across IT, networking, AV, and regulated environments.