140 kW · 208/120V Three-Phase · Modular Online Double-Conversion UPS · Competitive Comparison

M90U-140 vs Vertiv Liebert APM2 208V

The Xtreme Power M90U-140 and the Vertiv Liebert APM2 208V are modular online double-conversion UPS for 208V three-phase environments. The M90U-140 emphasizes higher usable N+1 headroom, segmented service-friendly battery architecture, and a standard internal maintenance bypass; the APM2 offers higher maximum expansion and multiple battery chemistry options. For facilities prioritizing high density, simplified maintenance, and standardized integration, the M90U-140 is a compact, service-optimized choice.

Xtreme Power
M90U-140
vs
Vertiv
Liebert APM2 208V
M90U-140 modular UPS with M90-BC battery enclosure in a data center electrical room

An M90U-140 with its M90-BC battery enclosure deployed in a live electrical room, alongside a row of distribution cabinets.

Where the M90U-140 leads

What the M90U-140 brings

  • Higher usable N+1 capacity (140 kW vs 120 kW).
  • Finer scaling below 30 kW (from 15 kW).
  • Segmented M90-BC battery cabinet with individually breakered strings, to 140 kVA.
  • Internal maintenance bypass included as standard.
  • Equal 23.6-in cabinet footprint with high power density.
  • Longer standard warranty coverage.
Side-by-side

Feature comparison

SpecificationXtreme Power M90U-140Vertiv Liebert APM2 208VAdvantage
Rated capacityUp to 140 kW N+1Up to 150 kWAPM2 maximum is higher (150 kW)
Available power sizes15–140 kW30–150 kWFiner scaling below 30 kW
N+1 redundancyUp to 140 kWUp to 120 kWGreater N+1 headroom
Modular architecturePower, battery & static-switch modulesPower modulesModular static switch
Battery chemistryVRLAVRLA or lithium-ionAPM2 adds a lithium-ion option
Modular VRLA battery cabinetM90-BC, 8 breakered strings, up to 140 kVAModular VRLA cabinet up to 120 kVAMore segmentation; higher VRLA capacity
Maintenance bypassInternal, standardInternal, optionalStandard, no added option
Online efficiencyUp to 94% (98% ECO)Up to 95.7%APM2 rates higher online (95.7%)
UPS cabinet width23.6 in23.6 inEqual footprint
Warranty2-year parts standard1-year partsLonger standard warranty

Both are modular online double-conversion UPS in a 23.6-in cabinet. The M90U-140 leads on usable N+1 (140 vs 120 kW), finer sizing below 30 kW, a modular static switch, M90-BC battery segmentation (8 breakered strings to 140 kVA vs 120 kVA), a standard internal bypass, and a longer warranty. The APM2 offers a higher maximum capacity (150 kW), a lithium-ion battery option, and a higher online efficiency rating (95.7% vs up to 94%). Confirm Liebert APM2 specifications against current Vertiv documentation.

Where each fits

Choosing between them

Choose the M90U-140 for higher usable N+1 (140 kW), finer low-end sizing, segmented breakered VRLA battery architecture, and a standard internal bypass; the Liebert APM2 fits facilities needing capacity beyond 140 kW, lithium-ion battery options, or standardization on Vertiv.

Choose the M90U-140 if you need

  • Usable N+1 to 140 kW in a 23.6-in cabinet
  • Finer scaling below 30 kW
  • Segmented M90-BC battery architecture with breakered strings
  • Internal maintenance bypass as standard
  • Longer standard warranty coverage

The Liebert APM2 208V may fit if you need

  • Maximum capacity beyond 140 kW (up to 150 kW)
  • Lithium-ion battery options
  • A higher online efficiency rating
  • Alignment with existing Liebert APM2 deployments

Plan your enterprise modular UPS deployment

Talk to an Xtreme Power specialist about sizing the right M90U-140 configuration and runtime architecture, planning N+1 redundancy to 140 kW and phased capacity expansion, and comparing modular three-phase platforms for data center, healthcare, industrial, and critical-infrastructure environments.