J90-2kLiD vs APC Smart-UPS Ultra SRTL2K2RM1UNC
The Xtreme Power J90-2kLiD and APC Smart-UPS Ultra SRTL2K2RM1UNC are both 1U online double-conversion lithium UPS at 2 kVA, 120 V. The J90 uses lithium iron phosphate (LFP); the SRTL2K2 uses lithium-ion. The J90 leads on chemistry, battery life, temperature, outlet control, TAA, and warranty; the APC carries a slightly higher VA rating and bundles network management.
What the J90-2kLiD brings
- LiFePO₄ chemistry with longer cycle life and thermal stability
- Up to 15-year battery life vs 8–10
- 50 °C operation (derates above 40) vs 40 °C
- Per-outlet control (the SRTL2K2 does not support it)
- TAA compliance and a 6-year warranty
Side-by-side specifications
| Specification | Xtreme Power J90-2kLiD | APC Smart-UPS Ultra SRTL2K2 | Advantage / consideration |
|---|---|---|---|
| Battery chemistry | Lithium iron phosphate (LFP) | Lithium-ion | J90 – longer cycle life, thermal stability |
| Battery life | Up to 15 yr / 3,000–5,000 cycles | 8–10 yr typical | J90 – fewer replacements |
| Topology | Online double conversion | Online double conversion | Equal zero-transfer protection |
| Capacity | 2000 VA / 1800 W | 2200 VA / 1870 W | APC – higher VA rating |
| High-temperature operation | Up to 50 °C (derates above 40) | Up to 40 °C | J90 – better in hot spaces |
| Outlet control | Individually controllable (Web/SNMP) | Not supported | J90 – per-outlet remote reboot |
| Runtime options | Internal + EBP (J90-EBP48) | Internal + EBP (SRTL50RMBP1U) | Scalable on both |
| Form factor / mounting | 1U rack or wall | 1U rack or wall | Equal flexibility |
| Network / management | Optional (SNMP-2PV3) | Integrated | APC – network management bundled |
| TAA compliance | Yes (COO Taiwan) | No (COO Philippines) | J90 – federal procurement eligible |
| Warranty | 6-year UPS & battery | 5-year limited | J90 – longer coverage |
Specifications based on publicly available manufacturer documentation; confirm against current vendor data. The SRTL2K2 carries a slightly higher VA rating and bundles network management; the J90 derates above 40 C.
Choosing between them
Both are 1U online lithium UPS. The J90-2kLiD leads on LFP chemistry, battery life, temperature, outlet control, TAA, and warranty; the SRTL2K2 carries a slightly higher VA rating and includes network management as standard. Topology, form factor, and EBP scalability are equal.
Choose the J90-2kLiD if you need
- LFP chemistry with extended service life and thermal safety
- Operation up to 50 °C
- Per-outlet control for remote reboot
- TAA compliance and a 6-year warranty
- Long service life with reduced maintenance
The APC Smart-UPS Ultra SRTL2K2 may fit if you need
- A slightly higher VA rating in 1U
- Integrated network management as standard
- Alignment with existing APC Smart-UPS Ultra deployments
Frequently asked questions
The J90 uses lithium iron phosphate (LFP) rated up to 15 years with better thermal stability and 50 C operation; the SRTL2K2 uses lithium-ion (8 to 10 years typical, rated to 40 C). The J90 also adds per-outlet control, TAA, and a 6-year warranty; the APC bundles network management and carries a slightly higher VA rating.
The APC, at 2200 VA / 1870 W versus the J90’s 2000 VA / 1800 W. Size to your actual load.
No. The SRTL2K2 does not support individually controllable outlets; the J90 does with the Web/SNMP card, for remote reboot of specific loads.
Yes. The J90 is TAA compliant (country of origin Taiwan), making it eligible for U.S. federal and regulated procurement; the APC unit is not.
Related comparisons
Comparing 1U online lithium UPS?
Xtreme Power supports sizing, runtime planning, and specification for edge IT, telecom, AV, and regulated environments.