50–70 kW · 400/230V & 480V · Rack-Integrated Online UPS · Vertiv Liebert APM2 (40–80 kW) Comparison

Ai90 vs Vertiv Liebert APM2

The Ai90 is a high-density modular rack-integrated UPS; the Vertiv Liebert APM2 is a modular UPS in a floor-standing cabinet. In the 40–80 kW range both support internal VRLA batteries for short-duration runtime. The APM2 spans a very wide capacity band and posts the highest peak online efficiency of the floor-standing platforms here; the Ai90 differs most in deployment model — rack-level integration versus a floor-standing cabinet.

Xtreme Power
Ai90
vs
Vertiv
Liebert APM2
Where the Ai90 leads

Where the Ai90 leads

  • Rack-level deployment — a 13U fully integrated system that installs in a standard rack rather than a floor-standing cabinet.
  • Over 5 kW per U power density within a 13U footprint.
  • UPS, internal modular battery, maintenance bypass, and output distribution integrated into one system.
  • Dual battery strings with a common breaker; short-duration ride-through optimized for generator transfer, scalable via 4U Ai90-EBC4 cabinets.
  • Unified UL and CE coverage across 480V and 400V configurations.
Side-by-side

Ai90 and Liebert APM2, side by side

SpecificationXtreme Power Ai90Vertiv Liebert APM2Advantage
Platform range50–70 kW10–120 kW platformAPM2 spans a wider range
UPS architectureModular rack-integratedModular floor-standingRack-level vs floor-standing
Form factor13U rack-mountedFloor-standing modular cabinetFits a standard rack
Dimensions17.2 × 36.2 × 22.75 in (13U)23.6 × 40.6 × 78.7 in~80% smaller volume
Power density>5 kW per UNot rack-density comparableHighest-density deployment
Efficiency (online)96.5%Up to 97.5%Comparable; APM2 up to 97.5%
Voltage coverageUL + CE across all configsUL or CE per configurationUnified UL + CE platform
Battery integrationInternal modularInternal modular VRLAEquivalent concept
Runtime strategyShort-duration internal or externalShort-duration internal or externalEquivalent strategy
DistributionIntegrated rack-levelExternal distribution requiredReduces external infrastructure
Maintenance bypassIntegratedIntegratedEquivalent functionality
InstallationRack deploymentFloor-standing installationFaster deployment

Both are modular UPS platforms with integrated bypass and internal-VRLA short-duration runtime. The Ai90 leads on deployment model, footprint, and density — about 80% smaller volume in a standard rack. The APM2 spans a wider 10–120 kW range and posts the highest peak online efficiency here (up to 97.5% vs 96.5%). Confirm APM2 specifications against current Vertiv documentation.

Where each fits

Choosing between them

Choose the Ai90 for rack-level deployment, high density, and integrated distribution within a standard rack. The APM2 fits where a floor-standing standard governs the facility, where single-platform capacity well beyond the Ai90 range (to 120 kW) is required, or where the Vertiv service ecosystem is required.

Choose the Ai90 if you need

  • Rack-level deployment inside a standard rack
  • Over 5 kW per U high density
  • An integrated UPS, battery, bypass & distribution system
  • Reduced external infrastructure and cabling
  • Faster install than floor-standing systems
  • Unified UL + CE across configurations

The Liebert APM2 may fit if you need

  • A floor-standing UPS standard already governs the facility
  • Single-platform capacity to 120 kW is required
  • The Vertiv service ecosystem is required

Plan your rack-integrated UPS deployment

Talk to an Xtreme Power specialist about rack-integrated UPS design, high-density deployment, runtime sizing with Ai90-EBC4 external battery cabinets, migration from floor-standing or legacy systems, and TAA-compliant procurement for AI/GPU compute, data center, edge, and industrial environments.