10 kVA / 10 kW · 208–240 VAC · Online Double-Conversion Rack UPS Comparison

P91-10K vs Vertiv Liebert GXT5-10KHVRT5UXLN

The Xtreme Power P91-10K (with the BPXR3U240A battery pack) and Vertiv Liebert GXT5-10KHVRT5UXLN are online double-conversion UPS delivering full 10 kVA / 10 kW at unity power factor, both on VRLA batteries. With equivalent usable power, the P91-10K differentiates on longer baseline runtime, optional XBDM modular bypass and distribution, a lower rack footprint, and built-in TAA compliance; the GXT5-10K emphasizes a single integrated UPS chassis.

Xtreme Power
P91-10K
vs
Vertiv
Liebert GXT5-10KHVRT5UXLN
Where the P91-10K leads

What the P91-10K brings

  • Much longer baseline runtime at 10 kW (6 min vs 2 min)
  • Lower rack footprint (5U with battery vs 6U UPS-only)
  • Optional XBDM modular bypass and distribution
  • Runtime scaling via BPXR battery options
  • TAA compliance for federal procurement
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-10K + BPXR3U240AVertiv Liebert GXT5-10KHVRT5UXLNAdvantage
Capacity10 kVA / 10 kW10 kVA / 10 kWEquivalent usable power
TopologyOnline double conversionOnline double conversionEquivalent protection
Output voltage208 / 220 / 230 / 240 VAC208 / 220 / 230 / 240 VACAligned voltage support
Runtime (full load)6 min at 10 kW2 min at 10 kWP91 – much longer runtime
External battery cabinetsYes (BPXR series)Yes (Vertiv EBCs)Both scale runtime
Input / output architectureHardwired or optional XBDM modular bypass & distributionHardwired input only; fixed output receptaclesP91 – modular bypass and distribution
Rack height5U total (2U UPS + 3U battery)6U UPSP91 – lower footprint (5U vs 6U)
Battery technologyVRLAVRLAComparable chemistry
Compliance / listingsUL1778, cUL, FCC, CE, RoHS, TAAUL1778, c-UL, CSA, FCC Class ABoth UL1778 listed
TAA complianceYesNoP91 – federal procurement
Warranty3 yr electronics / 3 yr battery3 yr electronics / 3 yr batteryEquivalent coverage

Specifications from Xtreme Power’s P91-10K vs Vertiv GXT5-10K comparison; confirm against current vendor documentation. P91-10K runtime shown with the BPXR3U240A battery pack.

Where each fits

Choosing between them

With equivalent 10 kW output, the P91-10K leads on runtime, rack footprint, modular bypass, and TAA; the GXT5-10K offers a single integrated chassis for Vertiv-standardized, non-regulated sites.

Choose the P91-10K if you need

  • Much longer baseline runtime at full 10 kW load
  • A lower total rack footprint for high-density environments
  • Modular bypass and distribution (XBDM) for service and expansion
  • Built-in TAA compliance for government, education, and public-sector
  • Flexible runtime scaling with BPXR options

The Liebert GXT5-10K may fit if you need

  • A single-chassis, integrated UPS architecture
  • Alignment with an existing Vertiv ecosystem
  • A non-regulated deployment with minimal runtime needs
Questions

Frequently asked questions

What competes with the Vertiv Liebert GXT5-10KHVRT5UXLN?

The Xtreme Power P91-10K (with the BPXR3U240A pack) is a common alternative, matching 10 kW of usable output while adding longer baseline runtime, a lower 5U rack footprint, optional XBDM modular bypass, and TAA compliance.

Do the P91-10K and GXT5-10K deliver the same usable power?

Yes. Both are rated 10 kVA / 10 kW at unity power factor, so usable real power is equivalent. The differences are runtime, rack height, serviceability, and TAA.

How much longer does the P91-10K run at full load?

With the BPXR3U240A pack the P91-10K delivers about 6 minutes at 10 kW versus about 2 minutes for the GXT5-10K. Both scale further with external battery cabinets.

Is the P91-10K TAA compliant?

Yes. The P91-10K is UL1778 listed and TAA compliant for federal and public-sector procurement; the GXT5-10KHVRT5UXLN is not TAA listed.

Specifying a 10 kVA online UPS?

Xtreme Power supports specification, runtime sizing, and design-in for enterprise IT, telecom, healthcare, education, and public-sector racks.