Web/SNMP Cards

UPS Management

Provide real-time monitoring, management, and control of remotely connected UPS from a web browser.

Category:

UPS management · Web/SNMP remote monitoring

Monitor and control your UPS from the network

Add real-time monitoring, alerts and graceful shutdown to an Xtreme Power UPS. Standards-based protocols let network, building and facility management systems read the UPS without custom drivers.

Real-time
Status, load and battery
RFC 1628
Standard UPS MIB
Modbus · BACnet
On the SNMP-2PG1 and SNMP-2PV3
3 years
Warranty, USA and Canada

Features

Remote visibility and control for your UPS

From a web browser you get real-time visibility into the UPS, the ability to manage it remotely, and automated protection for the systems it supports. Each card is matched to specific UPS families; use the compatibility guide below to choose.

Monitoring

Real-time UPS data

Status, load, battery and power conditions for a remotely connected UPS, from any web browser.

Shutdown

Graceful shutdown

Orderly, unattended shutdown of connected systems during extended outages.

Alerts

Notify the right people

SNMP traps and email alerts on power events, battery warnings and UPS alarms.

Integration

Standards-based SNMP

The RFC 1628 UPS MIB is supported by most network management systems, so no custom MIB is usually needed.

Security

Centralized authentication

HTTPS, SNMP v3 and RADIUS support on most cards. Protocols vary by card; see the specifications.

Environment

Environmental monitoring

Track temperature, humidity and other site conditions with optional probes on supported cards.


SNMP-2PG1

For modular and three-phase UPS: the SNMP-2PG1

The SNMP-2PG1 serves the Ai90, Li90, X90-1S, X90-2S, X90-5S, X90-10S, E91 10-20 kW, E91 30-40 kW, M90C-2S, M90C-6S, M90Ci-2S and M90Ci-6S. It is built for integration: building management, network monitoring and facility platforms read it with standard protocols, and the same data points apply across every UPS it supports.

The SNMP-2PG1 is the GENEREX CS141MINI-6 WEBMANAGER with XPC UPS interfaces. GENEREX develops and updates the network management platform, including security and firmware; XPC matches it to our UPS and supports it.

What the SNMP-2PG1 adds

  • SNMP v2c and v3 with the RFC 1628 UPS MIB and XPC extensions
  • Modbus TCP and BACnet/IP for building and industrial systems
  • Network shutdown of servers and virtual hosts with GENEREX RCCMD clients
  • Module count, per-module status and redundancy alarms on modular UPS
  • Energy (kWh), battery condition and battery age data
  • Designed to IEC 62443 and cybersecurity tested to UL 2900-1, with signed firmware, RADIUS and 802.1X
  • Made in Germany and TAA compliant; see TAA compliant UPS
  • Gigabit Ethernet, IPv4 and IPv6, remote syslog with TLS
  • SNMP v3 with SHA-256 authentication and AES encryption

Model selection

Web/SNMP card compatibility guide

Each card is matched to specific Xtreme Power UPS models. Find your UPS to identify the correct card and part number, then see the card details below. The A70i does not support a Web/SNMP card.

Card Part number Compatible Xtreme Power UPS
SNMP-2PV3 90000741 J90, J90i, J60C, P80, P80g, P91, P91g, P91 5-10k, P91 Li, P91g Li, T91, T91i, TX91, TX91L, TXVR, V70
SNMP-2P3 90000566 M90U, M90LU, M90U-80, M90U-140
SNMP-M90S 90000698 M90S-2S, M90S-4S, M90S-6S, M90S-12S, M90Si-6S. Same card as the SNMP-2P3.
SNMP-2PG1 90001245 Ai90, Li90, X90-1S, X90-2S, X90-5S, X90-10S, E91 10-20 kW, E91 30-40 kW, M90C-2S, M90C-6S, M90Ci-2S, M90Ci-6S
SNMP-J60 90000778 J60-600, J60i-600. The 350 VA models and the J60-600U do not take a card.
SNMP-USB 90000281 A60, S71

Card details

The other Web/SNMP cards

The SNMP-2PG1 is covered above. Each card below lists the UPS it fits, what it does and its documents and software.

SNMP-2PV3 Web/SNMP card

SNMP-2PV3

Part number 90000741 · internal card · made in Taiwan, TAA compliant

The internal Web/SNMP card for most single-phase Xtreme Power UPS, rack, tower and isolation models. It is built on the Megatec NetAgentA Mini (DA806) platform; Megatec develops the network management platform, and XPC matches it to our UPS, supplies the firmware and supports it.

For: J90, J90i, J60C, P80, P80g, P91, P91g, P91 5-10k, P91 Li, P91g Li, T91, T91i, TX91, TX91L, TXVR and V70

  • SNMP v1, v2 and v3 with the RFC 1628 UPS MIB
  • Gigabit Ethernet: auto-sensing 10/100/1000 Mbps
  • Modbus TCP and BACnet for building management and industrial systems
  • Web browser, HTTPS, SSL/TLS and SSH management; SNMP traps, email alerts and daily email reports
  • RADIUS authentication; IPv4 and IPv6
  • Optional SNMP-EMPV2 temperature and humidity sensor (Megatec NetFeeler Mini), which plugs into the card’s USB port
  • Obtains its IP address by DHCP; Netility finds the card on the network
  • Firmware updates (current version 3.14.DA806.XPC.1) are available from XPC technical service
  • Software: Netility (discovery and setup), ClientMate (shutdown), SNMPView (multi-UPS monitoring)

SNMP-2P3 Web/SNMP card

SNMP-2P3 and SNMP-M90S

Part numbers 90000566 (SNMP-2P3) and 90000698 (SNMP-M90S) · internal card

One internal card, sold under two part numbers: the SNMP-2P3 for the M90U family and the SNMP-M90S for the M90S family. It obtains its IP address by DHCP.

For: M90U, M90LU, M90U-80, M90U-140 (SNMP-2P3); M90S-2S, M90S-4S, M90S-6S, M90S-12S and M90Si-6S (SNMP-M90S)

  • Web browser monitoring and control, with the SNMP MIB for network management systems
  • 10/100 Ethernet; SNMP, HTTPS, SSL and SSH; IPv4 and IPv6; SMTP email alerts, SNTP time and Wake-on-LAN
  • Event and data logs with CSV export and daily email reports
  • Scheduled UPS on/off and battery tests
  • Optional SNMP-EMD temperature and humidity sensor
  • Software: SNMP Web Manager (setup), ViewPower Pro (multi-UPS monitoring)

SNMP-J60 external Web/SNMP box

SNMP-J60

Part number 90000778 · external box

An external Web/SNMP box for the J60-600 and J60i-600, which connect to it through their DB9 port. The 350 VA models and the J60-600U (USB HID) do not take a card.

For: J60-600 and J60i-600

  • Connects to the UPS RS-232 port with the supplied cable; powered by the UPS, no adapter needed
  • 10/100 Ethernet
  • Sensor port for an optional environmental monitoring device
  • Software: SNMP Web Manager (setup)

SNMP-USB external Web/SNMP box

SNMP-USB

Part number 90000281 · external box

An external Web/SNMP box with an LCD display, for UPS without an internal card slot.

For: A60 and S71

  • External box with LCD display; connects to the UPS USB port with its attached cable
  • Powered by the supplied 5.3 V DC adapter
  • Web browser management, SNMP traps and email alerts
  • Software: Netility (discovery and setup), ClientMate (shutdown), SNMPView (multi-UPS monitoring)

Specifications

Card specifications

Specification SNMP-2PV3 SNMP-2P3 / SNMP-M90S SNMP-2PG1 SNMP-J60 SNMP-USB
Platform Megatec NetAgentA Mini (DA806) GENEREX CS141MINI-6
Country of origin Made in Taiwan; TAA compliant Made in Germany; TAA compliant
Type Internal card Internal card Internal card External box External box
LAN interface 10/100/1000 Mbps 10/100 Mbps 10/100/1000 Mbps 10/100 Mbps
Ports LAN, USB (SNMP-EMPV2 sensor) LAN, sensor LAN, 2 × RS-232 (RJ12) LAN, RS-232, sensor
CPU / flash ARM9 180 MHz, 32-bit / 8 MB ARM Cortex-A8 800 MHz / 8 GB
SNMP v1, v2, v3 ✓ (MIB) v2c, v3
MIB RFC 1628, PPC MIB RFC 1628 with XPC extensions
Modbus TCP TCP; RTU over RS-232 with adapter
BACnet/IP ✓ ✓
LAN protocols TCP/IP, HTTP, HTTPS, SSL, SSH, SMTP, SNTP, DHCP, Telnet, BOOTP, DNS, DDNS, PPPoE, RADIUS, IPv4, IPv6 TCP/IP, UDP, HTTP, HTTPS, SSL, SSH, SNMP, SMTP, SNTP, DHCP, IPv4/IPv6, Wake-on-LAN HTTP, HTTPS, SMTP, NTP, DHCP, DNS, SFTP, RADIUS, 802.1X, remote syslog (TLS), Wake-on-LAN, IPv4, IPv6
Real-time clock ✓ ✓
Web multi-language ✓ ✓
UPS power cycle ✓ ✓ ✓ ✓ ✓
Environmental probes SNMP-EMPV2 (Megatec NetFeeler Mini, USB) SNMP-EMD SNMP-TMPH temperature and humidity probe; optional GENEREX SENSORMANAGER Optional, via sensor port
Power source Internal Internal Internal From the UPS External 5.3 V adapter
LCD display ✓
Dimensions (W × D × H) 2.0 × 3.1 × 0.9 in 2.7 × 4.9 × 1.1 in 1.7 × 2.8 × 1.0 in 2.0 × 4.0 × 1.4 in 1.7 × 2.2 × 0.75 in
Warranty 3 years (USA and Canada)

Blank cells are not published for that card; see its user’s manual.

Documents

Datasheets, manuals and software

Cards now obtain their IP address by DHCP. Quick start guides that describe a static default IP address apply to older cards.

Legacy cards

Not sure which card fits your UPS?

Tell us your UPS model and we will confirm the correct Web/SNMP card, part number and any environmental monitoring options.