15A, 20A, 30A, 63A
XBDM HW provides UPS maintenance bypass with input and output hardwired terminal block connections.
The XBDM HW provides UPS maintenance bypass with hardwired terminal-block input and output. Transfer critical loads from UPS power to utility power with a single bypass switch — so the UPS can be repaired or replaced without ever dropping the load.
The XBDM HW lets you manually transfer critical loads from UPS power to utility power using a bypass switch, enabling UPS repair or replacement without power interruption to the load. Transferring back to protected UPS power is just as easy — simply return the bypass switch to the UPS position.
Available in 15A, 20A, and 30A 120VAC ratings plus a 230VAC/63A model, the XBDM HW uses hardwired terminal-block connections for both utility input and system output. The 15A and 20A models add six 5–15R output receptacles and source-availability LED indicators, and keep connected loads surge protected even when the UPS is in bypass mode.
Hardwired input and output terminal blocks for direct connection to utility and load.
The 15A and 20A models also provide six 5–15R output receptacles for connected equipment.
LED indicators on the 15A and 20A models verify availability of UPS and utility sources at a glance.
Loads stay surge protected on the 15A and 20A models even in bypass mode; UPS electronics are protected during normal operation.
The 63A model provides make-before-break transfer and an interlock for the UPS static switch.
Wall and 19″ rack mounting hardware is included in the box.
A single bypass switch moves your critical loads between protected UPS power and direct utility power. Output to the connected loads always comes from the XBDM HW — so you can service or swap the UPS without ever dropping the load.
Utility power bypasses the UPS system and is supplied to the load directly — used while the UPS is serviced or replaced.
Power is routed through the UPS system to the connected load — the normal, fully protected operating state.
Terminal-block I/O plus six 5–15R receptacles, LED indicators, and surge protection.
Terminal-block I/O plus six 5–15R receptacles, LED indicators, and surge protection.
Hardwired terminal-block input and output with a 30A/1P input breaker.
Make-before-break transfer with static-switch interlock and a 63A/2P input breaker.
| Model number | XBDM-15RHW | XBDM-20RHW | XBDM-HW30 | XBDM-HW63 |
|---|---|---|---|---|
| Voltage / current | 120 VAC / 15 A | 120 VAC / 20 A | 120 VAC / 30 A | 230 VAC / 63 A |
| Utility input | Hardwired terminal block | Hardwired terminal block | Hardwired terminal block | Hardwired terminal block |
| Input breaker | N/A | N/A | 30A / 1P | 63A / 2P |
| Output | Terminal block + (6) 5–15R | Terminal block + (6) 5–15R | Hardwired terminal block | Hardwired terminal block |
| Transfer switch | 20A break-before-make rocker | 30A break-before-make rocker | 30A break-before-make rotary | 63A make-before-break rotary w/ interlock |
| Transfer time | 8 ms | 8 ms | 8 ms | 0 ms |
| UPS input connection | 5–20R | 5–20R | L5–30R | Hardwired or cable kit w/ Anderson connectors |
| UPS output connection | 3 ft cord, 5–15P plug | 3 ft cord, 5–20P plug | 3 ft cord, L5–30P plug | Hardwired or cable kit w/ Anderson connectors |
| AC surge | 6500 A, 114 J, 330 VAC | 6500 A, 114 J, 330 VAC | 6500 A, 114 J, 330 VAC | N/A |
| LED indicators | Utility, surge, UPS | Utility, surge, UPS | N/A | N/A |
| Dimensions (W×D×H) | 17 × 3.5 × 1.75 in | 17 × 3.5 × 1.75 in | 17 × 3.5 × 1.75 in | 17.25 × 5.25 × 3.5 in |
| Weight | 3.6 lbs | 3.6 lbs | 7.3 lbs | 7.1 lbs |
*XBDM-HW63 to be used with a bypass-interlock UPS.
Keep racks energized while a UPS is serviced in place.
Hardwired bypass for compact edge and distributed deployments.
Maintain ride-through on PLCs and production-line systems during UPS service.
Tell us your UPS rating and connection type and we’ll confirm the correct XBDM HW model and cable kit.
[table colalign=”left|left|center|center|center|center “]
,MODEL NUMBER,XBDM-15RHW,XBDM-20RHW,XBDM-HW30,XBDM-HW63*
POWER RATING,Voltage/current,120VAC/15A,120VAC/20A,120VAC/30A,230VAC/63A
INPUT,Utility input,Hardwired terminal block[attr colspan=”4″]
,Breaker,N/A[attr colspan=”2″],30A/1P,63A/2P
OUTPUT,Output,Hardwired terminal block + (6) 5–15R[attr colspan=”2″],Hardwired terminal block[attr colspan=”2″]
TRANSFER SWITCH,Capacity,20A break before make rocker switch[attr colspan=”2″],30A break before make rotary switch,63A make before break rotary switch w/ interlock
,Transfer time,8ms[attr colspan=”2″],8ms,0ms
UPS INPUT,Input connection,5–20R[attr colspan=”2″],L5–30R,Hardwired or cable kit w/ Anderson connectors
UPS OUTPUT,Connection to UPS output,3 ft cord with5–15P plug,3 ft cord with5–20P plug,3 ft cord with L5–30P plug,Hardwired or cable kit w/ Anderson connectors
AC SURGE,Capacity,”6500A, 114J, 330VAC”[attr colspan=”2″],N/A[attr colspan=”2″]
INDICATORS,LED indicators,”Utility, surge, UPS”[attr colspan=”2″],N/A[attr colspan=”2″]
PHYSICAL,Dimensions (W x D x H),17 x 3.5 x 1.75 in[attr colspan=”2″],17.25 x 5.25 x 3.5 in[attr colspan=”2″]
,Weight,3.6 lbs[attr colspan=”2″],7.3 lbs,7.1 lbs
WARRANTY,,3 years (USA and Canada) [attr colspan=”4″]
INCLUDED IN BOX,,”Standard 19 in rack mounting hardware, user manual”[attr colspan=”4″]
AVAILABLE OPTIONS,,Input cord sets and connectors[attr colspan=”4″]
[/table]