480V Modular UPS Platform

X90 Series 480V Modular UPS Systems

The X90 Series is Xtreme Power’s enterprise-class 480V modular UPS platform engineered for data centers, medical imaging environments, industrial infrastructure, and mission-critical facilities. Scalable from 50 kW to 700 kW, it supports centralized or distributed deployment and enables N and N+1 redundancy strategies.

All X90 Series systems are TAA compliant for federal, healthcare, and government applications, and the platform is widely deployed across regional edge infrastructure and distributed data environments. Learn more about UPS for Edge Data Centers.

X90-2S modular UPS installed in a hospital critical power electrical room, flanked by structured-cabling server racks
X90-2S modular UPS supporting critical medical imaging infrastructure
Capacity range
50–700 kW
Voltage
480 V
Redundancy
N · N+1
Compliance
TAA
Platform Configurations

Scalable 480V modular UPS power from 50 kW to 700 kW

The X90 platform scales by frame configuration — add power modules as load requirements grow, reducing initial infrastructure cost while maintaining high availability.

X90-1S
50–70 kW

Compact 480V modular UPS ideal for medical imaging rooms, small data rooms, and edge deployments.

View X90-1S →
X90-2S
50–140 kW

Expanded modular capacity frequently deployed in medical imaging and healthcare environments.

View X90-2S →
X90-5S
50–350 kW

High-capacity modular system for enterprise data centers and industrial applications.

View X90-5S →
X90-10S
50–700 kW

Large-frame modular UPS platform designed for centralized data hall deployments and large infrastructure environments.

View X90-10S →
Medical Imaging

Built for high-inrush imaging loads

The X90-1S and X90-2S platforms are particularly well suited for medical imaging environments, where modular architecture delivers the stability and headroom these systems demand:

  • High inrush tolerance for imaging start-up loads
  • Clean and stable power delivery
  • Scalable capacity for equipment upgrades
  • Reliable operation in hospital environments
Data Centers & Critical Infrastructure

Modular UPS for scalable power protection

Modular UPS systems provide scalable power protection for data centers, healthcare facilities, and industrial environments. The X90 Series allows organizations to add power modules as load grows — keeping availability high while controlling upfront infrastructure cost.

Enterprise data centers
Medical imaging facilities
Regional edge data centers
Industrial infrastructure environments
Federal & Government Ready

TAA-compliant three-phase UPS

All X90 Series configurations are TAA compliant, making them suitable for public-sector and government-adjacent deployments:

01
Federal healthcare facilities
02
Veterans Affairs hospitals
03
Government laboratories
04
Military installations
05
Public-sector infrastructure
View TAA-Compliant Three-Phase UPS →
Redundancy Architecture

Multiple redundancy strategies, one platform

Hot-swappable power modules allow service or module replacement without requiring a full system shutdown.

N configuration

Capacity matched directly to the protected load.

N+1 module redundancy

One additional module sustains availability through a module fault.

Hot-swappable modules

Replace power modules without a full system shutdown.

Maintenance bypass

Service the UPS while the load remains powered.

X90-1S / X90-2S

Maintenance bypass and battery modules are integrated within the UPS frame.

X90-5S / X90-10S

Add matching maintenance bypass and battery cabinets alongside the UPS frame.

Deployment Models

Distributed vs centralized UPS deployment

The X90 platform supports multiple power architectures.

Model A

Centralized deployment

Large-capacity UPS systems supporting entire rooms or data halls from a single protected source.

Model B

Distributed deployment

Segmented UPS protection by load group to improve fault containment and operational flexibility.

Hybrid architectures are commonly used in healthcare and enterprise environments.

Battery Technology

Battery flexibility: VRLA or Vision Lithium

The X90 Series supports multiple battery technologies depending on runtime and lifecycle requirements.

VRLA — Lead-Acid

Extended runtime, traditional cost basis

A proven solution for extended-runtime deployments where lowest upfront cost is the priority.

Vision Lithium Integration

Smaller footprint, longer service life

Reduced footprint, longer service life, and lower maintenance requirements. Explore Lithium UPS Technology →

Platform overview · 50–140 kVA range
480V Modular UPS for healthcare & imaging environments
480V Modular UPS 50–140 kVA →
FAQ

Frequently asked questions

What is a modular UPS system?
A modular UPS uses hot-swappable power modules to scale capacity and redundancy without replacing the entire UPS system.
What applications use 480V modular UPS systems?
480V modular UPS platforms are commonly used in data centers, medical imaging facilities, industrial infrastructure, and large commercial environments.
What redundancy options does the X90 support?
The X90 Series supports N and N+1 redundancy configurations, enabling high-availability power architectures.
Talk to Engineering

Speak with an Enterprise Power Specialist

Xtreme Power engineers help size, configure, and future-proof X90 deployments for healthcare, data center, and industrial environments.

Call Xtreme Power800.582.4524
Contact Engineering →
Load growth forecasting
Redundancy architecture planning
Runtime strategy
Generator coordination
Site-specific UPS configuration