Design-In Power · For Parking Equipment OEMs

Compact UPS for Parking Gates, Ticketing & Pay Stations

If you build the gates, ticket dispensers, pay stations, kiosks, and LPR housings that run the parking industry, the UPS you specify has to disappear into your enclosure, survive the field, and never become a warranty problem. Xtreme’s J60, J60C, and J90 families are engineered for exactly that — small enough to design in, rated for hot outdoor cabinets, and built on long-life lithium so the units you ship keep working for years.

Three reasons OEMs design Xtreme in: small dimensions that fit pedestals and shallow cabinets, long lithium battery life that cuts field failures and RMAs, and wide temperature tolerance for sun-loaded outdoor housings.

Compact Xtreme J60 lithium UPS designed into an equipment control panel beside a PLC and 24V power supply
J60 lithium UPS designed directly into an equipment control panel, alongside the PLC and power supply
Form factor
Pedestal & short-depth rack
Battery life
Up to 15 yr LiFePO₄
Operating temp
Up to 50 °C
Certification
UL-1778 · CE · TAA
Why OEMs Design It In

Selected on the specs that matter to a manufacturer

An embedded UPS isn’t bought on runtime alone — it’s bought on whether it fits, certifies, and stays out of your service queue.

Fits your enclosure

Small footprints drop into gate pedestals and behind panels; the short-depth J60C is just 8.5″ deep in a 1U chassis for shallow NEMA and wall-mount cabinets.

Fewer field failures

Long-life LiFePO₄ (up to 15 years) plus a 5-year battery warranty and dual-redundant BMS on 600 VA models means fewer swaps and RMAs on units already shipped.

Rated for the cabinet

Operates continuously to 50 °C and runs at up to 98% efficiency, so it adds little heat to a sealed housing where lead-acid would cook and fail early.

Clean certification path

UL-1778 / cTUVus / FCC on 120V and CE on 230V — and both are TAA compliant for federal, airport, and municipal parking work.

Serviceable in the field

Optional Web/SNMP (600 VA) reports status and alarms and supports remote shutdown/startup and output reboot — fewer truck rolls on remote sites.

Scales across your line

From 350 VA gate controllers to multi-kVA pay-station racks, one supplier across every product tier.

The Design-In Lineup

Three families, one parking-equipment toolkit

Xtreme J60 compact lithium UPS showing wall-mount brackets and side receptacles
J60 / J60i
Ultra-compact pedestal UPS

The smallest option — fits inside gate pedestals and behind kiosk panels for controllers, loop detectors, and small PCs.

350 VA / 200 W · 600 VA / 360 W
J60 = 120V UL · J60i = 230V CE · TAA
J60-350: 6.9 × 8.5 × 1.25 in · 3.4 lb
J60-600: 7.3 × 10.8 × 1.6 in · 4.7 lb
Up to 98% efficient · operates to 50 °C
5-yr electronics + battery warranty (US/CA)
J60 — World’s Smallest UPS →
Xtreme J60C short-depth 1U lithium UPS mounted in a rack with front LCD
J60C / J60Ci
Short-depth rackmount UPS

Short-depth 1U rack — just 8.5″ deep — for shallow outdoor cabinets and wall-mount racks, with a standard front-panel LCD. Ideal for LPR/NVR and higher-draw kiosks.

600 VA / 360 W · 1U · 8.5″ depth
J60C = 120V UL · J60Ci = 230V CE · TAA
17.2 × 8.5 × 1.7 in · 7.8 lb
Standard smart LCD · up to 98% efficient
5-yr electronics + battery warranty (US/CA)
Short-Depth Rackmount UPS →
Xtreme J90 1U online lithium UPS mounted in a rack with color status display
J90 / J90i
1U online lithium UPS

Steps up to true online double-conversion for larger pay-station PCs and lane controllers. Every outlet is individually switchable for remote per-outlet reboot — no separate PDU required.

1000–3000 VA / 900–2700 W · 1U · LFP
J90 = 120V UL/cUL · J90i = 230V · TAA
17.2 × 1.7 in · 18.8–22.8″ depth by model
Operates to 50 °C · all-switched outlets
Intelligent slot: Web/SNMP · Modbus · dry-contact
EBP48 for extended runtime · 6-yr warranty (US/CA)
J90 1U Lithium UPS →
Match UPS to Equipment

Solutions at a glance — parking / pay / LPR

A starting point for design-in. Final selection should be modeled on your exact device load and target hold-up time.

Parking equipmentTypical loadBest-fit UPSDesign note
Gate operator controller + loop detector 20–60 W J60-350VA / J60i-350VA Ultra-compact; fits inside the pedestal and rides through brownouts to avoid false opens.
Ticket / pay kiosk PC + peripherals 60–180 W J60-600VA / J60i-600VA Step up to J60C/J60Ci-600 short-depth rack for higher draw or longer hold-up.
LPR / ALPR / ANPR camera + edge NVR 40–120 W J60C-600 / J60Ci-600 Short-depth rack for outdoor cabinets; optional Web/SNMP for remote status.
Pay-station PoE switch 30–100 W J60-600VA / J60i-600VA Add SPDU for per-outlet remote reboot of downstream devices.
Centralized lane controller / larger pay-station PC 360 W+ J90 / J90i 1U lithium When the load or runtime exceeds the J60-600’s 360 W / 600 VA ceiling.

Runtime examples: J60-600 ≈ 23 min @120 W, 14 min @200 W · J60-350 ≈ 32 min @40 W, 17 min @80 W. See the Watts→Minutes runtime chart on the J60 page for full curves.

Integration & Field Service

Built to live in an outdoor cabinet

  • Brownout protection for gate logic and kiosk PCs — avoids false opens and failed transactions during sags, not just full outages.
  • Outdoor-cabinet friendly: short-depth J60C/J60Ci (8.5″ deep, 1U) fit shallow NEMA enclosures and wall-mount racks; J60/J60i tuck inside pedestals.
  • Flexible mounting: J60 ships with standard brackets for wall, under-counter, or in-enclosure mounting, with an optional DIN-rail kit for control panels.
  • Remote monitoring: optional Web/SNMP on J60-600 and J60C-600 for alarms, status, and remote shutdown/startup.
  • Per-outlet control: the J90’s outlets are individually switchable for native remote reboot; for J60-class units, pair with an SPDU for web-managed per-outlet on/off of downstream devices.

Operating note: the J60 family runs continuously to 50 °C (122 °F). The standard 5-year battery warranty applies to installations up to 40 °C; a 2-year battery warranty applies from 40–50 °C (USA & Canada).

Xtreme J60C short-depth UPS in a wall-mount cabinet with a network switch and rack PDU
J60C in a wall-mount edge cabinet with switch + PDU
Xtreme J60 UPS mounted on a DIN rail using the optional DIN-rail kit
Optional DIN-rail kit for control-panel mounting
Related Solutions

Explore the products & adjacent applications

FAQ

Design-in questions

What UPS should I design into a pay station?
Start from total Watts (PC + peripherals) and your target hold-up time. J60-600 / J60i-600 covers most kiosks; for larger PCs or longer runtime, move up to the J90 / J90i 1U lithium UPS.
Will it fit a shallow outdoor cabinet?
Use the short-depth J60C / J60Ci-600 for wall-mount racks and shallow NEMA enclosures; the J60 / J60i fit inside pedestals and behind panels. Confirm clearances against the unit dimensions before finalizing your enclosure.
Can field techs reboot equipment remotely?
Yes. Add an SPDU for per-outlet remote on/off and reboot of downstream devices. The J60-600 / J60i-600 and J60C-600 / J60Ci-600 also accept an optional Web/SNMP card to reboot the full UPS output, view status and alarms, and perform remote shutdown/startup.
120V UL or 230V CE — how do I choose?
Match it to your product’s destination market: North American builds use J60 / J60C (120V UL); international builds use J60i / J60Ci (230V CE).
Do you support volume design-in programs?
Yes — our engineers help with load sizing, runtime modeling, and configured BOMs for OEM programs. [CONFIRM: volume/channel pricing, lead-time, and sample-unit terms before publishing this answer]
Talk to Engineering

Design Xtreme power into your next product

Our engineers help parking-equipment OEMs size, configure, and integrate the right UPS — from a single gate controller to a full pay-station rack.

Call Xtreme Power800.582.4524
Talk to an Engineer → Request a Volume Quote →
Load sizing & runtime modeling
Configured BOM (UPS + SPDU + accessories)
Design-in & integration support