5 kVA / 5 kW · 208–240 VAC · Online Double-Conversion Rack UPS Comparison

P91-5K vs Dell-APC Smart-UPS On-Line DLRT5KRMXLT

The Xtreme Power P91-5K (paired with the BPXR2U240A pack) and Dell-APC Smart-UPS On-Line DLRT5KRMXLT are both true online double-conversion VRLA UPS for mission-critical IT. The P91-5K differentiates on higher usable watts, longer baseline runtime, modular bypass/distribution, and TAA; the Dell-APC emphasizes integrated management in a compact 3U UPS-only chassis.

Xtreme Power
P91-5K + BPXR2U240A
vs
Dell-APC
Smart-UPS On-Line DLRT5KRMXLT
Where the P91-5K + BPXR2U240A leads

What the P91-5K brings

  • Higher usable watt output (5 kW vs 4.25 kW)
  • Longer baseline runtime (7 min vs 4.4 min)
  • Broader voltage support (208–240 V)
  • Optional XBDM modular bypass & distribution
  • Built-in TAA compliance for federal procurement
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P91-5K + BPXR2U240ADell-APC Smart-UPS On-Line DLRT5KRMXLTAdvantage
UPS capacity5 kVA / 5 kW5 kVA / 4.25 kWP91 – higher usable watts
TopologyOnline double-conversionOnline double-conversionEquivalent premium protection
Output voltage208/220/230/240 VAC208/230/240 VACP91 – broader global voltage support
System runtime (full load)7 min @ 5 kW4.4 min @ 4.25 kWP91 – longer baseline runtime
Optional external battery cabinetsYes (BPXR series)YesBoth support runtime scaling
Input / output architectureHardwired or optional XBDM modular bypass & distributionL6-30P input; fixed receptacle setP91 – greater flexibility & serviceability
Rack height4U total (2U UPS + 2U battery)3U UPSDell-APC more compact; P91 trades 1U for runtime
Warranty3-yr electronics / 3-yr battery3-yr electronics / 3-yr batteryEquivalent coverage
Compliance / listingsUL1778, cUL, FCC, CE, RoHS, TAAUL1778, cUL, FCC Part 15 A, ENERGY STARP91 – adds TAA
TAA complianceYesNoP91 – federal procurement

Specifications from Xtreme Power’s supplied P91-5K vs Dell-APC DLRT5KRMXLT comparison; based on publicly available manufacturer data. The Dell-APC delivers 4.25 kW from a 5 kVA rating in a compact 3U UPS-only chassis; the P91-5K (shown with a BPXR2U240A pack) provides full 5 kW and longer baseline runtime.

Where each fits

Choosing between them

Both deliver online VRLA protection with external-cabinet expansion at equivalent warranty. The P91-5K leads on usable watts (5 vs 4.25 kW), voltage range, runtime, modular bypass/distribution, and TAA; the Dell-APC is more compact (3U) and fits Dell-APC-standardized environments favoring integrated management.

Choose the P91-5K + BPXR2U240A if you need

  • Higher usable watt output (5 kW vs 4.25 kW)
  • Longer baseline runtime without large external cabinets
  • Modular bypass and power distribution (XBDM)
  • Federally funded / TAA-restricted procurement

The Smart-UPS On-Line DLRT5KRMXLT may fit if you need

  • A more compact 3U UPS-only footprint
  • Alignment with an existing Dell-APC ecosystem and integrated management
  • Non-TAA commercial deployments with modest runtime needs

Specifying a centralized 5-10 kVA online UPS?

Xtreme Power supports UPS selection, runtime sizing, and distributed infrastructure design across IT, networking, AV, and regulated environments.