2000 VA · 120 VAC · Pure Sine Line-Interactive Rack UPS · APC Smart-UPS X Comparison

P80-2000 vs APC Smart-UPS X SMX2000LV

The Xtreme Power P80-2000 and APC Smart-UPS X SMX2000LV are 120V pure sine wave line-interactive UPS delivering 1800 W. The decisive difference is rack architecture: the P80-2000 fits the same power into 2U at 47 lb, where the SMX2000LV is a 4U unit at 85 lb.

Xtreme Power
P80-2000
vs
APC
Smart-UPS X SMX2000LV
Where the P80-2000 leads

What the P80-2000 brings

  • Same 1800 W in 2U vs APC’s 4U — half the rack height.
  • 47.4 lb vs 85.2 lb — roughly 38 lb lighter.
  • Optional XBDM maintenance bypass (APC: none).
  • Wall / 2-post mounting flexibility.
  • Up to 99% ECO-mode efficiency and a 3-year battery warranty.
Side-by-side

Side-by-side specifications

SpecificationXtreme Power P80-2000APC Smart-UPS X SMX2000LVAdvantage
Rated capacity2000 VA / 1800 W1920 VA / 1800 WEqual 1800 W; P80 higher nominal VA
UPS topologyLine-interactive, AVR, sine waveLine-interactive, AVR, sine waveEquivalent protection
Rack height2U4U (short depth)P80 half the rack height
Dimensions (W×D×H)17.2 × 18.9 × 3.5 in (2U)17.0 × 19.0 × 7.0 in (4U)P80 denser in-rack
Weight47.4 lb85.2 lbP80 approx 38 lb lighter
Input cord6 ft, NEMA 5-20PNEMA 5-20PEquivalent (both 20 A)
Output receptacles(8) NEMA 5-15/20R(6) 5-15R + (3) 5-20R + (1) L5-20RAPC more outlets (10 vs 8) + L5-20R
Extended runtimeYes (P90-BP48 packs)Yes (external packs)Equivalent
CommunicationsUSB, RS-232, optional Web/SNMPUSB, RS-232, SmartSlot (optional NMC)Both local; no cloud dependency
Maintenance bypassOptional XBDM moduleNoneP80 serviceable without downtime
EfficiencyUp to 99% ECO modeGreen modeP80 higher peak efficiency
TAA complianceYesYesBoth eligible
Warranty3-yr UPS & battery3-yr UPS / 2-yr batteryP80 longer battery coverage

Both are 2000-class line-interactive AVR sine wave UPS delivering 1800 W. The P80-2000 leads decisively on rack density and weight — the same power in 2U at 47 lb versus 4U at 85 lb — plus maintenance bypass, mounting flexibility, and battery warranty. The SMX2000LV offers more onboard outlets (10 vs 8) including an L5-20R. Real output watts are identical; P80 rates higher nominal VA. Confirm APC specifications against current APC documentation.

Where each fits

Choosing between them

Choose the P80-2000 for 2U rack density (vs APC’s 4U), far lighter weight, maintenance bypass, and wall/2-post mounting; the SMX2000LV fits APC-standardized sites wanting more onboard outlets where 4U height is acceptable.

Choose the P80-2000 if you need

  • Rack-density-constrained deployments (2U vs 4U)
  • Sites that handle and service their own units (weight)
  • Maintenance bypass for in-place service
  • Wall / 2-post branch and edge installations

The Smart-UPS X SMX2000LV may fit if you need

  • Standardization on the APC Smart-UPS ecosystem
  • Maximum outlet count and an L5-20R receptacle
  • Deployments where 4U height is not a constraint

Specify the right line-interactive rack UPS

Talk to an Xtreme Power specialist about UPS selection, runtime sizing with external battery packs, maintenance-bypass options, and rack / wall / 2-post deployment across IT, networking, AV, and regulated environments.