The Xtreme Power Conversion TX91-5kVA and the NXT Power Integrity Max NPTU5200-0 are true online, double-conversion UPS systems with integrated isolation transformers, designed for electrically noisy, mission-critical industrial, laboratory, and infrastructure environments. Both deliver galvanic isolation, strong surge suppression, and multi-voltage output flexibility.
However, the TX91-5kVA differentiates itself with longer internal runtime options, an XR extended-runtime variant, plug-and-play configuration flexibility, and built-in TAA compliance, making it particularly well suited for regulated and federal procurement environments.

5000VA Isolation UPS Comparison

Feature XTREME POWER TX91-5kVA NXT Integrity Max NPTU5200-0 XPCC Advantage
UPS Capacity 5000VA / 5000W (unity PF) 5200VA / ~5200W NXT slightly higher nominal VA rating
Topology Online Double Conversion
with Isolation Transformer
Online Double Conversion
with Isolation Transformer
Both provide galvanic isolation
ANSI/IEEE C62.41 Performance Yes Yes Equivalent surge performance
Output Voltage Options 120 / 208 / 220 / 230 / 240 VAC 120 / 208 / 220 / 230 / 240 VAC Equivalent multi-voltage flexibility
Internal Runtime (Full Load) ~10 minutes (up to ~15 minutes XR) ~5 minutes Longer internal runtime options
Optional External Battery Packs Yes Yes Equivalent runtime scalability
Dimensions (W × H × D) ~9.9″ × 32.4″ × 23.3″ 11.8″ × 28.4″ × 29.1″ TX91 is narrower and shallower
Input / Output Configuration Optional / configurable Optional / configurable Comparable flexibility
Warranty 3 years electronics
3 years batteries
3 years electronics
3 years batteries
Equivalent coverage
Compliance / Listings UL1778, cUL, FCC Class A, RoHS, TAA UL Listed, CE Marked, OSHPD/HCAi TX91 adds TAA compliance
TAA Compliance Yes No TX91 favored for federal procurement

Where the TX91-5kVA Excels

  • Federally funded and TAA-restricted procurement environments
  • Industrial and laboratory installations requiring galvanic isolation
  • Applications benefiting from longer internal runtime without external batteries
  • Deployments requiring XR extended-runtime flexibility
  • Space-constrained installations favoring a narrower, shallower footprint

When NXT Integrity Max NPTU5200-0 May Be a Fit

  • Facilities requiring OSHPD/HCAi-listed equipment
  • Existing NXT Integrity Max standardized deployments
  • Projects where TAA compliance is not required
  • Traditional industrial power-quality applications

Who Should Choose Which

Choose Xtreme Power Conversion TX91-5kVA if you need:

  • Integrated isolation with longer internal runtime options
  • Built-in TAA compliance for government, education, and public-sector projects
  • An XR extended-runtime option for longer backup requirements
  • A narrower, shallower isolation UPS for space-limited installations
  • Simplified procurement for regulated environments

Choose NXT Integrity Max NPTU5200-0 if you need:

  • Alignment with OSHPD/HCAi facility requirements
  • Slightly higher nominal VA rating
  • Deployment in non-TAA-regulated projects

Ideal Applications

  • Industrial control systems
  • Laboratory and test environments
  • Manufacturing and process automation
  • Federal, education, and public-sector facilities
  • Sensitive loads requiring galvanic isolation

Plan with Confidence

Request a Quote
Speak with an Xtreme Power Conversion specialist to size the right TX91 isolation UPS and runtime configuration for your application.

Xtreme Power Conversion
Phone: (800) 582-4524
Email: sales@xpcc.com