• TX90/T90 6kVA to 40kVA UPS
  • TX90/T90 Parallel System Diagram

TX90/T90 6kVA to 40kVA Parallel Scalable System

6kVA to 40kVA

240/120VAC or 208VAC

Online scalable UPS for high power and critical N+1 redundant applications.

Xtreme TX90 and T90 parallel N+1 redundant online Uninterruptible Power Supply (UPS) provides the ideal solution for the most demanding critical power requirements. Configurations up to 40kVA can easily be configured using individual 6kVA or 10kVA modules.

Xtreme N+1 configurations allow complete serviceability and redundancy. Should an individual UPS require maintenance, the UPS is automatically taken offline. A notification is provided to the user from the LCD display and an audible alarm. The failed UPS module may be serviced or replaced without the remaining UPS modules or connected load having to be powered down.

Product Snapshot

  • Redundant and scalable UPS with an output up to 40kVA
  • Galvanic isolated systems (TX90) provide full electrical noise isolation and 120/240V split-phase output
  • Transformerless systems (T90) provide the most economical solution for 200V, 208V, 220V, 230V, and 240V applications
  • Optional extended battery banks & chargers
MODEL NUMBER (Non-isolated)
MODEL NUMBER (Isolated)
T90-06K24
TX90-06K24
T90-12K24
TX90-12K24
T90-18K24
TX90-18K24
T90-24K24
TX90-24K24
INPUT Capacity 6kVA (5.4kW) 12kVA (10.8kW) 18kVA (16.2kW) 24kVA (21.6kW)
Capacity (redundant) N/A 6kVA (5.4kW) N+1 12kVA (10.8kW) N+1 18kVA (16.2kW) N+1
Voltage 160–280VAC*
Scalable All models are scalable to 24kVA or 18kVA N+1
OUTPUT Voltage TX90: 240/120VAC standard (100/110/115/200/208/230VAC are optional) T90: 208VAC nominal (200/220/230/240VAC selectable)
BATTERY Battery runtime (internal) 6 minutes at 100% load / 17 minutes at 50% load
PHYSICAL UPS dimensions (W x D x H) 11.4 x 25.4 x 29.5 in
Number of UPS modules 1 2 3 4
Optional external battery cabinets 11.4 x 25.4 x 29.5 in (EBP960, EBP940, EBP920)
Tie panel dimensions (W x D x H) 15.5 x 4.5 x 40.5 in
APPROVALS UL1778, cUL, CE, FCC A
SYSTEM INCLUDES UPS modules with internal batteries, 200A parallel tie panel with 40A module output breakers, parallel communication cables.
MODEL NUMBER (Non-isolated)
MODEL NUMBER (Isolated)
T90-10K40
TX90-10K40
T90-20K40
TX90-20K40
T90-30K40
TX90-30K40
T90-40K40
TX90-40K40
INPUT Capacity 10kVA (9kW) 20kVA (18kW) 30kVA (27kW) 40kVA (36kW)**
Capacity (redundant) N/A 10kVA (9kW) N+1 20kVA (18kW) N+1 30kVA (27kW) N+1
Voltage 160–280VAC*
Scalable All models are scalable to 24kVA or 18kVA N+1
OUTPUT Voltage TX90: 240/120VAC standard (100/110/115/200/208/230VAC are optional) T90: 208VAC nominal (200/220/230/240VAC selectable)
BATTERY Battery runtime (internal) 4 minutes at 100% load / 12 minutes at 50% load
PHYSICAL UPS dimensions (W x D x H) 11.4 x 25.4 x 29.5 in
Number of UPS modules 1 2 3 4
Optional external battery cabinets 11.4 x 25.4 x 29.5 in (EBP960, EBP940, EBP920)
Tie panel dimensions (W x D x H) 15.5 x 4.5 x 40.5 in
APPROVALS UL1778, cUL, CE, FCC A
SYSTEM INCLUDES UPS modules with internal batteries, 200A parallel tie panel with 60A module output breakers, parallel communication cables.

*Depending on load level; **Xtreme parallel tie panel is limited to 160A.